A 10-bit ADC can give an industrial controller a practical way to turn an analog voltage into digital data for monitoring, diagnostics, or control. The ADC101C021 and ADC101C027 are low-power, I2C-compatible converters designed for this role. Their combination of successive-approximation conversion, configurable operating modes, and threshold-related registers can simplify analog signal monitoring in embedded equipment.
The two devices share core conversion and interface functions, but differ in available pins and alert behavior. Understanding those distinctions—and how the ADC’s supply, input, and I2C bus affect integration—is important when selecting a device and planning a monitoring scheme.
How the 10-bit ADC converts an input
The ADC101C021 and ADC101C027 use a successive-approximation register architecture with an internal track-and-hold circuit. During the track phase, an internal sampling capacitor acquires the voltage at VIN. The converter then holds that sample and uses a charge-redistribution process to determine the corresponding digital code.
Conversion results use straight-binary format and 10-bit resolution, with no missing codes. The input range is from ground to VA, and VA also serves as the ADC’s reference. This makes the supply a measurement-critical signal: noise or instability on VA can affect conversion accuracy, so the data sheet calls for a low-impedance, well-decoupled supply that is free of noise.
The specified conversion time is typically 1 microsecond, and the maximum sample rate is 188.9 ksps. The supported supply range is 2.7 V to 5.5 V, while the operating temperature range is −40°C to +105°C. These characteristics make the devices relevant to compact monitoring and instrumentation designs where board space and power consumption matter.
Threshold monitoring and the alert function
A key feature of the ADC101C021 is its programmable out-of-range alert. Designers can set upper and lower conversion limits in the high-limit and low-limit registers. When a measured value crosses one of those limits, the device records an over-range or under-range condition in its alert-status register. The alert output can be configured for active-high or active-low operation.
Hysteresis helps prevent an alert from clearing as soon as the input moves marginally back across a threshold. After an over-range event, the reading must fall below the high limit by more than the programmed hysteresis value to clear the condition automatically. For an under-range event, it must rise above the low limit by more than that value. A configuration option can instead hold the alert until the controller explicitly clears the relevant status bit.
This behavior can support a simple monitoring workflow: configure limits, allow the ADC to monitor the input, and use the alert to prompt the controller to inspect status and conversion data. The alert is an indication that a programmed condition has occurred; system-level interpretation and response remain the responsibility of the host controller.
Automatic conversion and low-power operation
In normal conversion mode, reading the conversion-result register starts a new conversion. Automatic conversion mode provides a different approach: the ADC converts at a configured interval, allowing it to monitor an input without requiring the controller to initiate each sample. The conversion interval is selected through the configuration register, with available settings ranging from 32 to 2,048 conversion times.
In automatic mode, the device also maintains lowest- and highest-conversion registers. Each new result can update these stored extrema, giving the controller a way to retrieve the minimum and maximum observed values since those registers were cleared. This can be useful when a system needs to review excursions or operating range without reading every conversion result in real time.
Power behavior depends on the selected mode and interface activity. The ADC automatically powers down when it is not converting; the data sheet specifies less than 1 µW in one power-down condition. Designers should distinguish that state from automatic conversion, where the ADC remains active to take periodic samples, and from power-down operation while the I2C bus is active for communication with other devices.
I2C integration and device selection
The serial interface supports standard mode at up to 100 kHz, fast mode at up to 400 kHz, and high-speed mode up to 3.4 MHz under the stated bus-capacitance conditions. SDA and SCL are open-drain lines and require external pull-ups. Pull-up selection must account for bus capacitance and operating speed, and the system controller must use the device’s register pointer to select configuration, thresholds, status, or conversion data.
Package and address options distinguish the two variants. The ADC101C021 provides an ALERT output; its VSSOP-8 version also has address-selection inputs. The ADC101C027 is offered in a small SOT-6 package with an address-selection input and does not provide the alert output. The VSSOP-8 ADC101C021 supports up to nine pin-selectable addresses, while the SOT-6 ADC101C027 supports three. Confirm the required alert and address features against the specific package before finalizing a design.
Practical design considerations
- Protect measurement quality: Treat VA as both supply and reference, and provide appropriate decoupling and a low-impedance source.
- Check input drive: The data sheet recommends a source impedance below 100 Ω for best performance, particularly when sampling dynamic signals. A buffer may be needed, and filtering can help reduce input noise.
- Stay within the input range: VIN should remain between ground and VA during operation. The input protection diodes are not intended to clamp out-of-range signals.
- Plan the bus: Provide pull-ups on SDA and SCL, and verify that bus speed and capacitance meet the interface timing requirements.
- Match the variant to the system: Choose based on the need for an alert output, available package, and the number of devices sharing the I2C bus.
Conclusion
The ADC101C021 and ADC101C027 combine 10-bit successive-approximation conversion with an I2C interface suited to embedded analog monitoring. The ADC101C021 adds programmable threshold alerts and automatic monitoring features, while the ADC101C027 offers address-selection options without an alert pin. For system designers, the practical priorities are to select the correct variant, manage VA as a reference, observe input-drive and voltage limits, and configure thresholds and conversion behavior to match the monitoring task.