Access Official Technical PDF

Share Summary:LinkedInEmail

Spin photocurrents are electrical currents associated with spin-polarized carriers in semiconductor structures. In quantum wells (QWs), terahertz (THz) radiation can generate these currents without an applied voltage, making them useful probes of carrier spin, band structure and structural symmetry. The measured response depends on how the radiation is absorbed, the orientation and symmetry of the well, and whether an external magnetic field is present.

Three mechanisms are central: the circular photogalvanic effect (CPGE), the spin-galvanic effect (SGE) and the magneto-gyrotropic effect (MGE). They can produce related signals, but arise from different physical processes. Distinguishing them matters when interpreting measurements or using photocurrents to investigate spin behavior.

Why terahertz excitation is useful for spin photocurrents

Optical spin orientation transfers angular momentum from circularly polarized light to charge carriers. THz and mid-infrared excitation can drive transitions within a carrier population, including transitions between size-quantized subbands and indirect, or Drude, absorption processes. This enables monopolar spin orientation: excitation can involve one type of carrier without creating electron–hole pairs through interband transitions.

That distinction can help investigators examine spin relaxation without the electron–hole interaction and exciton formation associated with interband excitation. THz measurements also avoid some competing photocurrent mechanisms that can obscure relatively weak spin-dependent signals at visible wavelengths. They are not free of other effects, however; polarization and experimental geometry must be controlled to identify the current mechanism.

Circular photogalvanic effect: helicity selects carrier motion

The CPGE occurs when circularly polarized radiation excites carriers asymmetrically in momentum space. In a QW, optical selection rules and spin-split bands can make the carrier distribution depend on the light’s helicity. The resulting imbalance produces a directed current. Reversing the polarization from right- to left-handed reverses the current direction.

This mechanism requires a gyrotropic structure, in which the relevant symmetry permits a relationship between the light’s helicity and the current. The QW’s orientation affects what can be observed. For example, the reported CPGE response in (001)-oriented wells requires oblique illumination, while lower-symmetry structures can show a helicity-dependent current at normal incidence. Thus, a missing signal at one angle does not by itself rule out the effect; the crystal orientation and measurement geometry matter.

CPGE can accompany several absorption pathways:

  • Interband transitions excite carriers across the energy gap.
  • Intersubband transitions transfer carriers between quantized states within a band.
  • Intrasubband, or Drude, absorption involves free carriers absorbing radiation with assistance from scattering.

For direct intersubband transitions, the current can change sign as photon energy is tuned through an absorption feature. This spectral behavior is a useful way to identify the CPGE contribution.

Spin-galvanic effect: spin relaxation drives current

The SGE begins with a non-equilibrium spin polarization, but its current is generated differently from the CPGE. Spin-dependent scattering relaxes the polarized population asymmetrically in momentum space, producing a current even when the spin distribution is uniform across the sample. The SGE does not inherently require optical excitation; optical orientation is one way to create the initial spin polarization.

In many experiments, the CPGE and SGE can occur together. The CPGE is tied to selective optical excitation and momentum relaxation, whereas the SGE depends on spin-flip scattering during spin relaxation. Their different origins suggest practical ways to separate them. Time-resolved measurements can distinguish their decay when momentum and spin relaxation occur on different timescales. Spectral measurements can also help: near an intersubband resonance, a CPGE signal may change sign, while an SGE contribution can track the absorption strength.

An in-plane magnetic field provides another method for studying the SGE. Circularly polarized light can create spins oriented normal to a (001) QW; a magnetic field causes those spins to precess and develop an in-plane component. That component can drive an SGE current. Its dependence on magnetic field—the rise, maximum and subsequent decrease—can reveal information about spin relaxation, including the spin-relaxation time.

Magneto-gyrotropic currents under THz excitation

The MGE describes photocurrents that arise when light interacts with a gyrotropic structure in the presence of a magnetic field. Unlike the CPGE, an MGE current can occur with unpolarized radiation. With THz excitation, free-carrier (Drude) absorption and magnetic-field-dependent processes can generate spin-polarized currents.

The current’s direction and magnitude depend on the magnetic-field orientation, crystallographic axes and radiation polarization. Measurements may therefore compare opposite field directions and vary the polarization state. A current that reverses with the magnetic field but does not change with light polarization is distinguishable from contributions that depend on linear or circular polarization. These dependencies provide a framework for separating components, though identifying the underlying microscopic process requires considering the sample and absorption conditions.

Using photocurrent measurements to investigate QWs

Spin photocurrents offer electrical access to properties that are otherwise difficult to assess directly. In particular, the SGE can help investigate Rashba–Dresselhaus spin splitting in size-quantized subbands, while the time evolution and field dependence of the current can provide information about spin relaxation. The photocurrent’s response to incidence angle, polarization and crystal orientation can also help determine QW symmetry.

For reliable interpretation, measurements should account for:

  • Symmetry and orientation: these determine which current components are allowed and whether normal or oblique incidence is required.
  • Polarization: reversing helicity tests for a CPGE contribution; varying linear polarization can reveal other photogalvanic terms.
  • Magnetic-field geometry: field direction can control spin precession and select magneto-gyrotropic responses.
  • Photon energy: tuning across an absorption feature can distinguish mechanisms with different spectral signatures.
  • Timing: transient measurements can help separate momentum-relaxation and spin-relaxation contributions.

Conclusion

Terahertz spin photocurrents are more than a light-induced electrical signal: their behavior reflects the interplay of spin, momentum, scattering and symmetry in a quantum well. CPGE, SGE and MGE can overlap, so no single measurement condition necessarily identifies a mechanism. Combining polarization, magnetic-field, spectral and time-resolved measurements provides a more informative picture of carrier spin dynamics and QW structure. For researchers developing and characterizing spin-dependent semiconductor devices, these effects offer complementary experimental routes to examine spin splitting and relaxation.