ScopeCorder data acquisition can help engineers investigate systems where electrical waveforms, physical measurements and control-network activity need to be examined together. Rather than treating each signal type as a separate measurement task, a modular recorder can capture and analyze multiple inputs on a shared time base. This is useful when a brief transient, a changing operating trend or the relationship between a command and a physical response matters.
For industrial automation teams, the practical challenge is often not simply collecting more data. It is choosing suitable inputs, sampling rates, recording duration and triggering methods for the behavior under investigation. ScopeCorder and high-speed acquisition systems offer different combinations of those capabilities, so selection should start with the measurement problem.
What ScopeCorder data acquisition is designed to capture
A ScopeCorder is a portable data acquisition recorder intended to capture transient events as well as longer-term trends. Its modular inputs allow teams to combine measurements such as voltage and current with sensor outputs for temperature, vibration, acceleration, strain and frequency. Depending on the main unit and installed modules, digital logic and vehicle-network signals can also be monitored.
This combination supports analysis of dynamic electromechanical systems. For example, an engineer may want to compare an electrical signal with a pressure, temperature or vibration measurement, or examine how a network message relates to a changing sensor output. Viewing these signals together helps make their timing and correlation available for investigation without relying on separate, unsynchronized recordings.
Triggering is important when the event of interest is short or infrequent. ScopeCorders can capture single-shot or rarely recurring signals, while waveform computations and automatic parameter measurements can support analysis of repetitive behavior. Depending on the instrument and configuration, triggers can be based on signal conditions or calculated quantities.
Choosing between the DL950, DL350 and SL1000
The DL950, DL350 and SL1000 address different acquisition requirements. Their headline specifications are not interchangeable: channel counts, record capacity, interfaces and operating arrangements depend on the unit, selected modules and options.
DL950 for larger, synchronized measurements
The DL950 provides eight plug-in module slots and can support up to 32 analog channels with specified module configurations. Its listed maximum sampling rate is 200 MS/s, with bandwidth up to 40 MHz depending on the input module. Options include expanded memory, internal SSD storage, time-synchronization interfaces and multi-unit synchronization. With the multi-unit option, the system can extend measurement across multiple units; the catalog describes configurations of up to 160 channels.
For vehicle development and evaluation, the DL950 can be configured to monitor CAN, CAN FD, LIN and SENT signals. Decoded network information can be displayed as trend waveforms and compared with analog measurements. A power-math option is also described for analyzing electrical power-related quantities while recording mechanical variations such as motor speed and torque.
DL350 for portable field work
The DL350 is a compact, two-slot ScopeCorder with AC, DC or battery operation. Its modular inputs support different combinations of signal types, while the instrument can record to internal memory or an SD memory card. The catalog lists up to 100 MS/s sampling, subject to the module used, and describes extended recording to SD card for long-duration measurements.
Its portable design can suit measurements away from a laboratory, including field troubleshooting and mobile tests. The /VE vehicle option and compatible modules support monitoring of CAN, CAN FD, LIN or SENT signals alongside analog sensor data. Optional GPS input can synchronize positioning information with waveform data, subject to local radio regulations.
SL1000 for PC-based, multi-unit acquisition
The SL1000 is a high-speed data acquisition unit normally controlled by a PC. One unit supports up to 16 input channels, and up to eight units can be synchronized for a maximum of 128 channels. It supports sampling up to 100 MS/s on all channels and provides acquisition software for configuring measurements, displaying waveforms and saving data. With the internal hard-drive option, it can also record without a connected PC.
Plan the measurement before selecting modules
Start by defining the event or trend that must be captured. A fast transient may call for a higher-speed input module and a suitable trigger, while a temperature or strain test may prioritize sensor compatibility and longer observation time. For each signal, confirm:
- Signal type: voltage, current, temperature, strain, acceleration, frequency, logic or supported bus data.
- Timing needs: required sampling rate, bandwidth and synchronization between channels or units.
- Recording duration: memory capacity, internal storage and whether removable media or PC streaming is appropriate.
- Input configuration: module compatibility, channel count, isolation and any required accessories.
- Operating environment: portability, available power and the controls needed for unattended or remote measurements.
Module compatibility matters: not every input module works with every main unit, and some configurations require a vehicle option, scanner box, probe-power option or firmware update. Probes are not included with modules. Engineers should verify the applicable specifications and accessories for the exact instrument configuration before connecting signals.
Turning captured waveforms into useful analysis
Acquisition is only one part of the workflow. ScopeCorder functions can include waveform math, automatic parameter measurement, trend display and analysis of historical or repetitive waveforms. The DL350 lists T-Y, X-Y, FFT and harmonic analysis functions. The SL1000 software supports waveform display and analysis, as well as saving data for later processing. These functions can help teams move from observing a signal to comparing channels, identifying when an event occurred and reviewing recorded behavior.
For repeatable work, engineers should also document module choices, channel assignments, trigger conditions, sampling settings and storage destinations. Consistent setup information makes later review easier and helps distinguish a genuine change in machine behavior from a difference in measurement configuration.
Conclusion
ScopeCorder data acquisition provides a flexible approach to capturing electrical, physical and selected network signals in dynamic systems. The DL950 is oriented toward broader modular and synchronized measurements, the DL350 toward portable acquisition, and the SL1000 toward PC-based, multi-unit recording. The right choice depends on the signals, timing, duration and environment involved. Matching those requirements to compatible modules and a clear recording plan is the key step toward collecting data that supports practical troubleshooting, validation and engineering analysis.