Access Official Technical PDF

Share Summary:LinkedInEmail

Shock data logging gives engineers a way to document acceleration events that may affect equipment, products or sensitive assemblies. In applications ranging from trucks and shipping containers to electronics production lines, recorded data can help characterize the dynamic environment rather than relying on assumptions about how severe or frequent impacts may be. A three-axis logger captures motion along the X, Y and Z axes, with configuration choices determining how much detail is recorded and how available memory is used.

Using three-axis shock data logging

A tri-axial shock logger measures acceleration in three directions. Each axis can be enabled or disabled to suit the measurement task. When fewer channels are active, the storage otherwise assigned to those channels becomes available to the enabled ones. This can be useful when a test is focused on a particular direction, although the appropriate axes depend on how the device is oriented and what motion needs to be understood.

Shock and acceleration measurements can be valuable in mobile environments such as vehicles, trucks, containers and ships. They can also help characterize conditions on production and assembly lines handling delicate electronics, integrated circuits, communications equipment or computer components. In each case, the logger must be configured to capture events at a useful level of detail for the expected environment.

Choose a measurement range for the expected shock

Measurement range is a key setup decision. The Shock300 uses separate accelerometers for lower- and higher-level measurements, with selectable ranges of ±15 g, ±100 g or ±300 g. The selected range applies to the logging session. The listed resolution and calibrated accuracy vary by range, so the choice involves matching the expected acceleration to the measurement capability needed for the task.

Orientation matters as well. The logger’s X, Y and Z directions are marked on its front face. If an axis points upward, that axis reports approximately +1 g due to gravity. Recording the mounting orientation as part of test documentation helps make the resulting axis data easier to interpret.

Mounting affects measurement fidelity

The mechanical connection between a logger and the object being monitored influences how shock and vibration reach its accelerometers. A rigid, bolted attachment to a solid, flat surface is generally the preferred arrangement for transferring motion faithfully. Where bolting is impractical, adhesive mounting may be an option, but the joint itself becomes part of the measurement system.

For an adhesive attachment, consider three factors:

  • Keep the adhesive layer as thin as practicable.
  • Ensure it can support the logger under the expected temperature, shock and vibration conditions.
  • Choose a stiff material where the application permits.

A softer mounting material can reduce the transfer of higher-frequency vibration, while a stiffer attachment generally more closely approaches the signal transfer of a bolted mount. This means inconsistent mounting between test runs can complicate comparisons, even if the logger settings remain unchanged.

Peak and instantaneous recording capture different events

Logging mode determines what is retained between recorded points. In peak mode, the accelerometers internally sample at 512 Hz and the logger stores the peak value found during each logging interval. This approach can capture a short-lived maximum that occurs between the intervals at which data are saved.

In instantaneous mode, a measurement is taken at the selected logging rate. If that rate is one reading every 30 seconds, the logger records a single point at each 30-second instant. A brief shock occurring between those points may not appear in the dataset. The risk depends on the event’s duration and waveform, so instantaneous capture is most appropriate when the sampling interval suits the behavior being measured. Where transient peaks are important, peak recording can provide a more useful record, subject to the available mode and rate settings.

Use triggers to focus storage on significant events

Axis-specific trigger thresholds can be configured as absolute values. A trigger can help conserve storage by concentrating data collection on measurements above a chosen level. After a trigger, users can choose to continue filling the available memory or store a set number of samples.

The post-trigger sample count should reflect the time window needed for analysis. For example, 100 samples at a 30-second logging interval span 3,000 seconds. That may include substantially more data than is relevant to a short shock event. Conversely, a count that is too small may leave insufficient context after the trigger. Trigger settings have a significant effect on storage use but, according to the device guide, virtually no impact on battery life.

Plan memory, power and data handling

Available storage and battery capacity are separate constraints. Storage use varies with the number of active channels, reading rate and trigger configuration. At high sampling rates, continuous recording can consume memory quickly; triggered operation can reserve storage for qualifying events and a user-defined post-event buffer. In some applications, storage capacity may exceed what the battery can support, requiring external power.

Before deployment, configure the start method, reading interval, stop condition, channels and recording mode in the logger software. Once recording is complete, stop the device and download the dataset to a computer for review. A logger that has stopped because memory is full, or has been manually stopped, must be re-armed from a computer before it can record again.

Make setup part of the measurement plan

Reliable shock data depends on more than selecting a logger. Engineers should align range, axis selection, mounting, recording mode and trigger behavior with the event they need to observe. Documenting those choices supports more meaningful comparisons across tests and helps avoid overlooking brief impacts or filling storage with irrelevant samples.

For industrial automation and operations teams, the practical value of shock data logging lies in turning dynamic conditions into a reviewable record. A deliberate setup helps ensure that the data reflects the equipment or product environment as closely as the mounting and selected measurement settings allow.