Wearable sensor technology brings several measurement methods together in a compact, battery-powered system. For engineers evaluating connected devices, the central design challenge is not simply fitting sensors into a small enclosure. Measurement quality also depends on where the device is worn, how signals are acquired, how motion and environmental interference are handled, and how power is managed. A wearable reference platform illustrates how optical, biopotential, impedance, motion and temperature sensing can be combined to monitor human-body parameters.

Wearable sensor technology depends on placement

The measurement location influences both the signals available and the sensing method that is practical. The wrist is a familiar location for smart watches and other wearable devices. The head is another option, including headphones or earbuds, while chest-worn devices can use electrode-based measurements. A chest strap has been used for heart-rate monitoring, and chest patches offer another form factor.

For heart-rate measurement, biopotential sensing detects electrical signals using two or more electrodes. The signals are relatively strong when measured across an appropriate part of the body, but a single-point wrist measurement is not suited to capturing them in the same way. Optical sensing is more appropriate for a single location: light enters the tissue, and a photodiode measures changes in reflected light associated with blood flow. This method can provide beat-to-beat information, but motion and ambient light can interfere with the measurement.

These tradeoffs matter to system architects because a sensor choice cannot be separated from the device’s form factor and intended use. A platform designed to move between wrist and chest placement, for example, needs to accommodate different sensing arrangements rather than treating all measurements as interchangeable.

Optical sensing: signal acquisition and interference

A photoplethysmogram (PPG) system uses light-emitting diodes (LEDs) to illuminate tissue and photodiodes to receive the returning signal. The described reference platform uses an optical analog front end that controls LED pulses and processes the photodiode signal. Its configurable transimpedance amplifier converts the received photocurrent into a voltage, while subsequent signal-conditioning stages prepare the signal for digitization.

Ambient light is a significant design consideration, particularly when the interference is modulated, as can occur with LED-based lighting. The optical front end includes a bandpass filter and integrator that support synchronous demodulation, helping reject external light interference. The block can also be bypassed when ambient-light rejection is not needed.

LED pulse timing and current are configurable, and the system can average multiple samples to improve the effective resolution of the acquired signal. The platform supports green, red and infrared LEDs, providing flexibility in optical design. Mechanical integration is equally important: LED and photodiode selection, spacing and the window between the optical components and the body can affect performance. A shared window can simplify the mechanical arrangement, but optical crosstalk must still be addressed.

Combining biopotential, impedance and motion measurements

The reference design also includes two single-lead ECG analog front ends. Each is intended to extract, amplify and filter small biopotential signals in noisy environments. Their filtering can be configured for different measurement needs, from detecting the QRS complex for heart-rate monitoring to capturing a broader ECG signal range. External resistors and capacitors set the frequency band, so changing the desired bandwidth may require hardware changes.

The device’s electrodes can also support electrodermal activity (EDA), sometimes called galvanic skin response (GSR). This measurement tracks changes in skin conductivity. In the described approach, an AC excitation signal is applied across two dry electrodes, and the resulting signal is processed to estimate skin impedance or conductance. The use of AC excitation avoids polarizing the electrodes.

Motion sensing provides another important input. Movement can disrupt optical heart-rate readings, so a three-axis accelerometer can help identify activity and support compensation for motion artifacts. The reference platform’s motion sensor also offers a low-power activity-triggering mode, in which it periodically checks for movement rather than continuously operating at its highest sampling rate. This illustrates a common embedded-design tradeoff: sampling requirements, response time and battery consumption need to be considered together.

Power, processing and system integration

In a wearable device, sensing performance must be balanced against operating time. The platform separates its main functions across two stacked circuit boards. One handles processing, Bluetooth Low Energy communication and power management; the other carries the sensing technologies. This arrangement brings the measurement electronics together while retaining a dedicated system board for communications and battery functions.

Two processors are used in the design: one on the interface board and another on the sensor board. The sensor-side microcontroller can collect data and run algorithms, or operate in a lower-power mode with its analog front end and peripherals active while data is transferred to memory using direct memory access. The design also includes temperature measurement, using sensors to monitor both skin and device temperature.

For engineers assessing a wearable architecture, the practical questions include:

  • Measurement location: Does the intended placement support the selected sensing method?
  • Interference: How will the design address motion, ambient light and electrical noise?
  • Signal conditioning: Can gain, filtering and sampling be configured for the measurement objective?
  • Power budget: Which functions need to run continuously, and which can operate intermittently?
  • Mechanical design: How do component spacing, electrodes and enclosure windows affect the sensing arrangement?

Conclusion: design around the measurement

Wearable sensor technology is a system-level engineering problem. Optical, biopotential, impedance, motion and temperature sensing each impose different requirements on placement, electronics, mechanical construction and power management. The reference design shows how these functions can coexist in a compact platform, while underscoring that accurate readings depend on thoughtful signal conditioning and interference control. For technical decision-makers, the key is to define the measurement objective and wearing location first, then evaluate the sensor, processing and power architecture as an integrated system.