In industrial control and embedded systems, a clock source may need to serve several devices while maintaining a predictable timing relationship. A zero delay clock buffer addresses this by distributing a reference clock through multiple outputs and using feedback to align output timing with the input. The CY23EP09 is a nine-output device designed for 2.5 V or 3.3 V operation, with a specified frequency range that depends on its drive-strength version and supply voltage.
How the CY23EP09 distributes a clock
The CY23EP09 accepts an input clock at REF and uses an on-chip phase-locked loop (PLL) to generate buffered clock outputs. The PLL’s feedback path is taken from the CLKOUT pin. This feedback lets the device compensate for propagation through the buffer and achieve near-zero input-to-output delay when the outputs are configured and loaded appropriately.
The device provides two banks of four outputs, CLKA1–CLKA4 and CLKB1–CLKB4, plus CLKOUT. In total, that gives the system nine outputs: eight bank outputs and the feedback output. Select inputs S1 and S2 control which banks are active and whether the reference clock is routed directly to the outputs. Bank B can be three-stated when its outputs are not required, and the selection modes also support clock routing for testing.
Zero-delay performance depends on output loading
“Zero delay” is not independent of the board-level design. The PLL compares its feedback at CLKOUT with the reference input, and the relative loading of CLKOUT and the other outputs affects their timing relationship. The datasheet identifies an internal 5 pF load on CLKOUT, in addition to any external load connected to that pin.
For zero input-to-output delay, the total load on every output—including CLKOUT—should be equal. For example, when CLKOUT has no external load, the other output pins need an additional 5 pF of load to match its internal load. If the application calls for an intentional adjustment to input-to-output delay, changing the CLKOUT load changes the timing relationship between REF and the remaining outputs.
Output-to-output skew also depends on load matching. To minimize skew, load all outputs equally. The datasheet gives a typical output-to-output skew of 45 ps under specified equal-loading conditions; actual limits and results depend on the operating conditions and drive option. Unequal trace capacitance or connected-device input loads should therefore be considered when planning the clock tree.
Frequency, supply voltage, and drive strength
The CY23EP09 family has standard-drive (-1) and high-drive (-1H) versions. The high-drive option supports higher maximum frequencies than the standard-drive part, but the maximum also varies with supply voltage:
- 3.3 V: up to 220 MHz with high drive, or 167 MHz with standard drive.
- 2.5 V: up to 200 MHz with high drive, or 133 MHz with standard drive.
These maximum-frequency ratings apply under the datasheet’s specified loading conditions. Allowable load capacitance also changes with frequency, voltage, and drive strength. For example, the stated limits include loads up to 30 pF below 100 MHz in several configurations, while the allowable load is lower at higher frequencies. Check the operating-condition tables for the exact combination relevant to the design rather than treating the headline frequency as independent of load.
The device’s clock-quality specifications likewise need to be read with their conditions. The datasheet lists typical cycle-to-cycle jitter of 25 ps and typical period jitter of 15 ps, while detailed electrical tables provide values for particular supply, load, frequency, and drive-strength combinations. These figures are not universal guarantees for every configuration.
Power-down and PLL-bypass behavior
When REF has no rising edges—at frequencies below approximately 2 MHz—the PLL enters power-down mode, and the outputs are three-stated. The datasheet specifies less than 25 µA of current draw in this state. This behavior is relevant when designing clock-startup, stopped-clock, and low-power operating sequences.
A separate mode is selected when S2:S1 is 1:0. In this configuration, the PLL is bypassed and REF is passed to the outputs from DC up to the device’s maximum allowable frequency. The part then behaves as a non-zero-delay buffer, and its outputs are not three-stated. Designs that use this mode should account for its different timing behavior rather than assuming PLL-based alignment.
Design checks for system integrators
Before selecting or laying out the device, verify the following against the application’s clock requirements:
- Confirm supply voltage, input frequency, drive strength, and output load are within the specified operating limits.
- Match output loading when low output-to-output skew or zero input-to-output delay is required.
- Include the CLKOUT internal 5 pF load when calculating total output capacitance.
- Choose select-input states deliberately, especially if Bank B must be disabled or PLL bypass is required.
- Check startup behavior and ensure the power supply ramps monotonically to its specified minimum voltage.
- Confirm the required package and temperature grade; industrial-temperature versions are specified for an ambient range of -40 °C to 85 °C.
The CY23EP09 is available in 16-pin SOIC and TSSOP packages. It is not intended for applications requiring 5 V-tolerant inputs, so input compatibility must be checked as part of interface design.
Conclusion
The CY23EP09 provides a practical way to distribute one reference clock across multiple destinations while using PLL feedback to manage timing alignment. Its performance depends on more than the nominal frequency: supply voltage, drive strength, output capacitance, load symmetry, and select-pin configuration all matter. For engineers integrating the device into a control or embedded system, careful clock-tree loading and verification against the specific datasheet conditions are essential to achieving the intended delay and skew behavior.