Kinetix 5700 servo drives are designed for machine applications with high axis counts and significant power requirements. Selecting a system involves more than matching a motor to an inverter: engineers must also account for the shared DC bus, 24V control power, peak-load duty cycles, cable lengths, enclosure heat and protective devices. Understanding how these specifications interact helps integrators and machine builders develop a motion system suited to the application.
Kinetix 5700 servo drives: architecture and application fit
The Kinetix 5700 family combines power-supply modules with single- or dual-axis inverters. The modules connect over EtherNet/IP and operate with ControlLogix, GuardLogix, CompactLogix or Compact GuardLogix controllers. Logix Designer and Studio 5000 provide a shared control and design environment for the motion system.
Available power components include conventional DC-bus power supplies and regenerative bus supplies. Inverters provide the motor outputs, while system accessories can extend the DC bus, store energy or provide additional shunt capacity. An iTRAK power supply is also available for integrating an iTRAK system with the drive family. The architecture gives designers choices, but the selected modules and accessories must be treated as a coordinated system.
Match bus supply and inverter ratings to the load
The DC-bus power supplies listed in the specifications accept 324–528V AC, three-phase input and provide a nominal DC-bus output range of 458–747V. Their continuous bus output ratings range from 10.5 to 69.2 A, with continuous power output from 7 to 46 kW, depending on the model. Peak output ratings are time-limited, so they should not be treated as continuous capacity.
Regenerative bus supplies are another option for systems designed to return energy to the AC supply. The listed models provide 35.3–207 A of continuous bus output current and 24–140 kW of continuous output power. Unlike the conventional DC-bus supplies, these regenerative units do not have an internal shunt resistor. Confirm the operating mode and compatible components during design; the publication notes that the regenerative supplies have a different AC input range when DC-bus voltage regulation is enabled.
Inverter sizing also requires attention to both continuous and peak current. The listed single-axis models span 43–192 A of continuous output current, while dual-axis models are rated per axis and range from 2.5 to 23 A continuous. Peak current is available only for specified durations. For example, some high-power single-axis models provide separate overload ratings for 1-, 3- and 60-second intervals. A load profile should therefore identify peak current, time at peak, base current and duty cycle—not just the highest expected current.
Plan 24V control power as a system load
The 24V DC supply must support the combined control-power demand of the drive modules and accessories. Demand varies by catalog number and can increase when motors have holding brakes. Capacitor modules, DC-bus conditioner modules and iTRAK equipment also affect the calculation. For iTRAK, the power-supply figure alone does not include the connected motor modules’ control-power demand.
Use the module-level current information to calculate the total load, including applicable brake current, and check inrush requirements. The specifications identify inrush durations of less than 30 ms for the listed modules. Treating the 24V supply as a system-level design item helps avoid overlooking loads that are not reflected in the inverter’s motor-power rating.
Account for installation, cable and enclosure limits
Mechanical layout and cable routing can constrain a design as much as electrical ratings. The documented combined motor-power cable length depends on the supply and EMC line filter: applications using a DC-bus supply and a 2198-DBxx-F filter allow up to 400 m, while specified combinations using a 2198-DBRxx-F filter allow up to 1200 m. The publication states that 2198-DBxx-F filters are not compatible with regenerative bus supplies. Drive-to-motor cable limits vary with feedback type, reaching up to 90 m for some types and 30 m for incremental feedback. Confirm the requirements for the selected motor and system configuration.
Enclosure planning should use the power-dissipation data for each module at the expected operating level. Heat losses vary with product and percentage of rated output; for instance, the listed 2198-S312 single-axis inverter dissipates 610 W at 20% rated output and 1,965 W at 100%. Add the applicable losses across the system when planning enclosure ventilation.
The Kinetix 5700 environmental specifications list an operating ambient range of 0–50°C, relative humidity of 5–95% noncondensing and an IP20 protection class. The drive system’s altitude limits and derating conditions also matter: the publication specifies derating above 1,500 m in applicable installations and different maximum altitudes depending on the input-power grounding arrangement.
Include protection and safety in the design review
Branch-circuit protection must be selected according to the applicable drive model and installation requirements. The specifications provide fuse and circuit-breaker selections for different supply modules and standards contexts. The drives include solid-state motor short-circuit protection, but suitable branch-circuit protection is still required. Verify the selected device, system configuration and certification requirements against the relevant product documentation.
The listed Kinetix 5700 drives have functional-safety certification up to SILCL 3 and Performance Level e, Category 3, when used as described in the applicable manuals. This is not a substitute for machine-level safety engineering: the safety function, architecture and installation must follow the relevant safety documentation. EtherNet/IP conformance testing and other agency certifications are also identified in the specifications.
Turn specifications into a complete motion-system design
For practical selection, assess the application in a consistent order: define the motor and load profiles, choose a bus supply and inverter combination, calculate 24V control demand, verify peak-current duration, and check cable compatibility and length. Then review protection, enclosure heat, environmental conditions, mounting clearances and safety requirements. The Kinetix 5700 specifications provide the component-level data for these checks; final selection should also be confirmed against the applicable user manuals and motion-control selection guidance.
The key implication is that servo-drive sizing is a system exercise. A suitable design must satisfy continuous and transient motion demands while remaining compatible with the bus architecture, control-power supply, cabling, thermal environment and protective devices. Evaluating those factors together gives engineers and operations teams a more dependable basis for specifying and integrating multi-axis motion control.