Weld current monitoring gives production and engineering teams a way to measure resistance-welding current and assess results against configured limits. The MIYACHI TECHNOS MM-122A Weld Checker combines current and weld-time measurement with upper and lower limit judgment, discrete I/O, and serial communications. Its value in an automation system depends on matching the measurement settings to the welding process and wiring its signals correctly.

What the MM-122A measures

The MM-122A is designed for resistance-welding power supplies. It supports several welding-current types, including single-phase AC, AC inverter, DC inverter, transistor, and capacitor welding. Depending on the selected method, weld time can be measured in cycles or milliseconds. For AC welding, the instrument can also display conduction angle.

Current results can be shown as either an effective (RMS) value or a peak value. The measurement interval can be configured with a start point, FIRST, and an end point, LAST, for applicable measurement modes. This allows the measurement to cover a selected portion of the weld rather than necessarily treating every part of a cycle or weld sequence as equivalent. The manual notes that these start and end settings do not apply in capacitor welding mode.

Current range is selectable, and the measurement method, range, and peak-or-effective selection are settings that should be matched to the welding equipment and the intended measurement. The current type selected is common to the instrument’s 31 schedules, while current range and peak/effective selection can be set by schedule.

Using weld current monitoring for limit judgment

The MM-122A can compare measured current and weld time with configured upper and lower limits. The front panel indicates whether a result is within the configured range or above or below it. In-range results are identified as NORMAL; out-of-range results are identified as HIGH or LOW. The instrument also provides a no-current indication when the corresponding detection input is used.

These judgments can be connected to a PLC or other control equipment through the I/O connector. The available outputs include GOOD, NG-H, NG-L, and NG+24V signals. The manual describes GOOD as the in-range result and the NG signals as indications associated with results outside limits or specified fault conditions. Output behavior and hold settings vary by signal and configuration, so the control-system design should follow the relevant pin descriptions and timing information.

Limit judgment is a monitoring function: it reports whether measured values meet the settings entered in the instrument. For useful process control, engineers need to establish limits that reflect the welding requirements for the application and verify that the selected measurement window and current type are appropriate.

Connecting the instrument to a production system

The toroidal coil senses welding current. Install its coil portion around a suitable part of the current path, such as the electrode holder or secondary cable. The manual cautions against installing it on the movable portion of the welding head, which can cause malfunction or damage. It also warns that repeatedly bending or straightening a band-type coil may break its internal wire.

The MM-122A provides inputs for functions such as schedule selection, reset, measurement stop (GATE), no-current detection, and counter reset. Schedule selection through the I/O connector takes priority over a schedule selected on the instrument. The schedule-select signal must be applied at least 2 ms before welding current flows; the schedule cannot be changed during measurement. The GATE input must be applied at least 10 ms before current flows, and it cannot be accepted during measurement.

Input wiring depends on the PLC output type. The manual provides connection arrangements for contact or NPN (sink-type) inputs and PNP (source-type) inputs. The unit can be powered from 100–240 VAC or 24 VDC, subject to the specified connection requirements. When using 24 VDC through the I/O connector, the manual calls for an overcurrent protective circuit and says not to connect the AC power cable.

Schedules, counters, and communications

Up to 31 schedules can hold current and weld-time upper and lower limits. This supports selection of different judgment settings for different welding conditions. A schedule can be chosen at the instrument or through external I/O, with external selection taking priority when its inputs are used. The COUNT mode displays weld counts and supports preset-counter and step-up-counter functions.

For data exchange with a computer, the instrument supports RS-232C or RS-485 communication. The factory setting is RS-232C, so the communication method must be checked on both the Weld Checker and the connected system before commissioning. Multiple MM-122A units can be connected on RS-485 when the specified system configuration is used; the manual calls for unique device numbers and 100-ohm terminal resistance at both ends of the RS-485 cable.

Commissioning considerations

Before using the measurement results for process decisions, confirm the following:

  • Select the measurement method that corresponds to the welding power supply and process.
  • Choose the appropriate current display, range, and measurement interval.
  • Configure the current and weld-time limits for each required schedule.
  • Verify coil placement and ensure it is not attached to a moving portion of the welding head.
  • Check PLC input type, signal timing, output wiring, and reset behavior against the I/O pin descriptions.
  • Confirm the serial communication mode and device addressing before exchanging data.

Installation conditions also matter. The manual advises against placing the unit in damp, excessively hot or cold, dusty, condensing, chemical-handling, or high-frequency-noise locations. Electrical and welding safety precautions should be observed during installation and operation.

Conclusion

The MM-122A brings resistance-welding current and weld-time measurement together with configurable limit judgment and interfaces for automation equipment. For engineers and integrators, dependable use starts with selecting the right measurement mode, setting meaningful limits, positioning the toroidal coil correctly, and validating I/O timing and communications. These commissioning steps help ensure that the signals supplied to production controls represent the intended weld measurement and judgment.