Stepper motor terminals can simplify how a motor axis is connected to and controlled from an industrial automation system. The KL2531 and KL2541 combine two-phase motor output stages with motion functions and diagnostic feedback, while fitting into a Bus Terminal system. Their different power ranges make them suited to different drive requirements, but successful integration still depends on selecting and configuring the motor, supply and mechanics as a complete system.

Stepper motor terminals for different performance ranges

Both terminals control two-phase stepper motors using regulated sine/cosine phase currents. Their current controllers operate at approximately 25 kHz, and both support full-step, half-step and microstepping operation up to 64-fold. The terminals also support a maximum step frequency of 125 kHz.

The KL2531 is the lower-power option. Its motor output supply range is 8 to 24 VDC, with a maximum output current of 1.5 A. It includes two 24 V digital inputs for limit switches and is designed for small motors and adjustable axes integrated with a 24 VDC control system.

The KL2541 serves a higher performance range. Its output supply range is 8 to 50 VDC and its maximum output current is 5 A. It adds an incremental encoder interface, as well as two digital inputs for end-position signals. The encoder interface and digital inputs can also be used with 5 V signal levels. A KL2541-0006 variant provides a 5 V encoder supply.

Both models provide a motor-load indication based on the load angle, and their process data and LEDs expose status and error information. The KL2541’s encoder interface offers an additional feedback path. Load-angle feedback should not be treated as equivalent to full position feedback or as a substitute for an encoder in applications that require actual position measurement.

What microstepping changes in an application

In a basic stepper drive, the rotor advances between motor positions as the phase currents change. Microstepping divides this movement into smaller increments by shaping the currents in the two motor phases. The terminals offer up to 64-fold microstepping, which can make motion smoother and reduce the abrupt rotor movement associated with larger steps.

This approach can help address resonance, a condition in which mechanical and electrical characteristics cause a motor to run less smoothly or, in severe cases, fail to follow commanded steps. Microstepping can reduce the tendency to excite resonance in many standard motor applications, but it does not remove the need to assess the motor and load under actual operating conditions. The terminal’s load-angle indication can help identify changing motor load, although its reading is influenced by velocity, resonance, acceleration and current settings.

Match the motor to the mechanics and motion profile

Terminal selection is only one part of drive sizing. The required torque changes with speed, acceleration, friction, transmission efficiency and the inertia of both the motor and the driven load. A practical sizing process starts with the required positioning resolution and motion timing, then works back from the load toward the motor shaft.

  1. Establish the required resolution, including the effect of the motor step angle, microstepping and any mechanical transmission.
  2. Determine the mass and moment of inertia of the moving components, along with the required acceleration.
  3. Calculate the forces and torques needed across the motion profile, accounting for friction, efficiencies and transmission ratios.
  4. Compare the resulting speed-and-torque requirements with the motor’s characteristic curve. Include the motor’s own inertia in the assessment.
  5. Check the proposed combination under real operating conditions, including continuous operation, temperature, resonance, mechanical play and ramp settings.

The documentation recommends a 20% to 30% torque margin when selecting a motor, while noting that optimization can differ when acceleration is primarily needed to overcome rotor inertia. Treat the margin as part of the sizing guidance, not as a replacement for application testing.

Configure motion and power deliberately

The terminals support operating modes that include direct velocity control, velocity control with ramps, position tracking and path control. In path control, a controller can provide a 32-bit target position together with motion parameters such as velocity and acceleration; the terminal then executes the move when enabled. For more demanding positioning tasks, the terminals can also be integrated as axes in TwinCAT.

Configuration parameters let the user adapt settings such as motor current, velocity limits and acceleration. Current reduction can limit unnecessary motor heating: the terminal can apply a configured holding current at standstill, and manual reduction is also available. Settings should be chosen for the motor and application rather than copied without verification. In particular, changing current-control options can affect motion, and disabling Mixed Decay may cause a small position shift of a few microsteps in the worst case.

Power-supply sizing also requires care. For typical applications, the documentation gives an estimate based on 50% of a stepper motor phase’s current consumption. That estimate is not suitable for every load: where the motor experiences larger load torques, actual maximum current consumption should be measured and used to size the supply.

Commissioning, diagnostics and wiring

Before enabling motion, verify the motor and terminal parameters, supply voltage, wiring and control-system process data. The LEDs and status information can help distinguish a configuration problem from a supply or load error. For example, configuration diagnostics can identify required parameters set to zero, while other indications cover conditions such as low supply voltage, an open motor load or overcurrent.

Pay particular attention to signal wiring on the KL2541. Its input path is designed for fast signal transmission, with rising- and falling-edge propagation times specified as less than 10 μs. Because additional input filtering would increase delay, short pulses may reach the evaluation logic without filtering or attenuation. Shielded cables are recommended for signal inputs to help avoid external interference, and the signal source must provide edges steep enough to be received reliably.

Installation and commissioning should be carried out by qualified personnel following the applicable standards and the device documentation. The terminals are rated IP20 and have a specified operating ambient range of 0 to 55 °C. Installation position, ventilation and mechanical loading should be checked against the relevant product instructions.

Practical implications for machine design

KL2531 and KL2541 stepper motor terminals offer an integrated route to controlling two-phase stepper axes, with the KL2531 aimed at lower-power drives and the KL2541 adding higher output capacity and encoder connectivity. Their microstepping, operating modes and diagnostics can reduce the amount of separate drive hardware and interface work needed for suitable applications. The key engineering task remains matching the motor, power supply, mechanics and control parameters to the real motion profile, then validating the complete axis during commissioning.

Access Official Technical PDF

About The Author