The K1G position sensor is a through-beam measurement system for determining the position and dimensions of workpieces. An emitter projects a laser beam toward a receiver containing a line image sensor; an object placed between them changes the received-light profile. The controller uses that profile for measurements such as edge position, edge condition, gap width, and the width of opaque or transparent objects. For engineers planning an installation, measurement performance depends not only on the sensor heads but also on their alignment, the installation environment, wiring, grounding, and configuration.
How the K1G position sensor measures workpieces
The K1G system consists of paired sensor heads and a controller. The emitter and receiver face one another, with the workpiece positioned in the beam path. The controller processes the receiver’s light profile to determine the selected measurement. The series supports sensor-head measurement widths of 7 mm and 15 mm, and a controller can connect up to four sets of heads.
Depending on the application and configuration, the system can be used to detect an edge, assess edge status, measure a gap, or determine widths based on blocked or transmitted light. This makes the measurement principle relevant to tasks where a workpiece’s position or boundary must be monitored. The appropriate measurement function and settings depend on the process requirements and the selected controller configuration.
Plan the installation around alignment and environment
Mount the emitter and receiver so their optical surfaces face each other, and secure both heads to a stable fixture. The heads should not loosen under vibration or shock, and the workpiece must not contact them. Check their orientation during mounting and make sure the emitter and receiver have matching serial numbers; using a mismatched pair may prevent the system from meeting its listed specifications. Avoid touching the optical surfaces during installation.
Consider the operating environment before selecting a mounting location. The manual cautions against exposure to outdoor weather, direct vibration or shock, corrosive or combustible substances, steam, dust, oily smoke, direct splashes of water or processing chemicals, electrical noise, strong magnetic fields, and strong light. Dirt or ambient light interference can affect measurement. Keep dust, oil, water, and fingerprints off the emitting and receiving surfaces, and use shielding to prevent external light around 650 nm from reaching the receiver.
Route and secure cables so they are not strained at the sensor head or connector. Use a bend-tolerant junction cable when installation on a moving part requires it. Junction cables connect the sensor-head cables to the heads and are available in standard and bend-tolerant types; they cannot be connected end-to-end with another junction cable.
Wiring and grounding for reliable integration
Disconnect power to the controller and connected equipment before mounting, removing, or wiring the device. Confirm model and terminal numbers against the controller label, check all connections before energizing, and do not use unused terminals as relay terminals. The specified supply is 12–24 V DC; applying AC power can cause damage or fire. Tighten terminal screws to 0.4–0.6 N·m and use crimp terminals compatible with M3 screws.
Keep input/output signal wiring at least 50 cm from motor power wiring and power lines, and do not place the two types of wiring in the same conduit or duct. Use the specified cable types and lengths for the particular connections. For the general-purpose K1G-C04G controller’s inputs and outputs, the manual specifies JCS4364-compliant twisted, shielded instrument cable or equivalent. Power cables should meet the stated conductor-area, voltage, and temperature requirements, and cable length must not exceed 30 m.
Ground the controller’s frame-ground terminal. Networked models have an additional network frame-ground terminal: connect it for the MECHATROLINK-III K1G-C04MG and EtherCAT K1G-C04EG as specified. The manual warns that inadequate grounding can result in electromagnetic interference. It also calls for ferrite cores on sensor-head and power cables. Follow the model-specific instructions for ferrite placement and cable routing.
Match communication cabling to the controller
Choose the communication connection to match the controller model and host system. The K1G-C04MG supports MECHATROLINK-III and requires industrial mini I/O connectors; RJ-45 connectors are not compatible. The K1G-C04EG supports EtherCAT and uses Cat 5e or higher shielded twisted-pair cable. In electrically noisy environments, the manual recommends double-shielded STP cable and describes grounding the shield at both ends. Check the EtherCAT IN and OUT connections carefully: connecting to the wrong port prevents communication.
Allow for startup and configuration
After power-up, allow at least 30 minutes for the circuitry to stabilize before use, because measured values may change gradually during this period. Measurement begins about one second after power is turned on, while analog or digital outputs start after their output response time. For EtherCAT, verify startup behavior against the master’s specifications and check operation on the actual system.
Initial setup can include analog-output and digital-I/O settings, a measurement cycle, receiver adjustment, and communication parameters such as the MECHATROLINK-III station address or EtherCAT ID, where applicable. The K1G-C04G, K1G-C04MG, and K1G-C04EG CE- and KC-marked controllers covered by the manual cannot use a 250 μs measurement cycle. Select settings based on the exact controller model and application rather than assuming every option applies to every version.
Safety considerations and practical implications
The sensor heads use a Class 1 semiconductor laser. Do not look directly into the beam or through an optical device, and do not disassemble or modify the heads. The sensor is not intended for safety circuits designed to protect people. If the equipment becomes wet or damaged, or produces an unusual smell or smoke, turn off power and stop using it.
For a sound integration, treat optical alignment, environmental protection, cable routing, grounding, and controller configuration as parts of one measurement system. Confirm the specific controller model and its communication requirements, protect the optical surfaces from contamination and interfering light, and follow the prescribed power and wiring practices. These steps provide a practical foundation for using K1G measurements in a PLC, motion-control, or other industrial automation architecture.