Effective inverter sizing is a system-level engineering task. Selecting a drive from motor power alone can overlook the application’s speed range, load torque, duty cycle, ambient conditions and braking requirements. A structured selection process helps engineers choose a suitable motor-inverter combination and identify supporting components before detailed design and commissioning.
Start with the application requirements
Before choosing an inverter, define the operating conditions the drive must meet. Useful inputs include the operating mode, maximum load torque, minimum and maximum load speed, installation altitude and temperature inside the control cabinet. The application’s acceleration, deceleration and stopping requirements also matter, particularly where the motor regularly operates as a generator.
These inputs help establish the required speed-adjustment range and the motor’s rated operating point. A motor with an integral fan and a motor with a separate blower can have different usable adjustment ranges. The cooling method therefore needs to be considered alongside speed and torque; extended operation at low speed can create a motor-overheating risk for self-ventilated designs.
Inverter sizing: choose the motor and drive together
Selection can be approached at different levels. A quick method uses the motor data for a four-pole asynchronous motor as a starting point. A more detailed approach sizes the complete drive system around the application’s physical requirements. A manual calculation is also possible when the required motor and load data are available.
A practical workflow is to:
- Define the operating mode and load requirements.
- Calculate the speed-adjustment range and identify the rated point.
- Select a motor based on rated torque, speed, current and power.
- Apply correction factors for inverter operating conditions.
- Select an inverter using its output-current capability.
- Check the motor-inverter combination and required overload capacity.
- Determine whether braking equipment is needed, then finalise accessories and installation requirements.
Motor torque and rated speed should be checked against the load’s maximum torque and speed range. The inverter’s continuous output current must also be sufficient for the motor after applicable correction factors are considered. Relevant factors include site altitude, control-cabinet temperature and switching frequency. The available data for the selected inverter and load characteristic should be used for these checks rather than relying on nominal kilowatts alone.
Match the load characteristic to duty
Drive applications differ in their dynamic demands. A high-dynamic application may require substantial short-term overload capacity, while a pump or fan may operate with lower dynamic requirements. The drive’s load characteristic should reflect that distinction.
The documented i550 options illustrate the trade-off between Heavy Duty and Light Duty. Heavy Duty is associated with applications such as hoists, winders, forming drives and main tool drives. Light Duty is intended for applications including pumps, fans and some horizontal material-handling or line drives. Light Duty allows a higher output current with restrictions on overload capability, ambient temperature and switching frequency. Its overload-sizing factors also differ from those for Heavy Duty. Confirm that the chosen characteristic suits the load and that all associated electrical and thermal data are followed.
Account for time-limited overload
Some applications demand current above the inverter’s rated current for a limited period. Such operation must be evaluated as a repeating cycle, including both the overload interval and the recovery period. For the cited i550 operating cycles, one profile permits up to 200% of rated current for three seconds, followed by 12 seconds at no more than 75%. Another permits up to 150% for 60 seconds, followed by 120 seconds at no more than 75%.
These are bounded operating profiles, not continuous ratings. Device-utilisation monitoring can trigger the configured fault response if the utilisation threshold is exceeded. The relevant rated data must be checked for the specific inverter and switching frequency; overload behaviour may also be reduced at rotating frequencies below 10 Hz.
Plan for regenerative energy and braking
During motor operation, electrical energy flows from the supply through the inverter to the motor. During generator operation, the motor returns energy to the inverter—for example, when a load is lowered or a drive decelerates. This energy raises the DC-bus voltage. If it exceeds the permissible range, the inverter can block its output stage, allowing the drive to coast.
For small inertias, DC-injection braking may provide deceleration without an external brake resistor, but its braking torque is lower than braking in generator mode with an external resistor. Where greater inertia must be decelerated or generator operation lasts longer, an external brake resistor may be required to convert braking energy into heat. Resistor selection should account for the application’s braking power, braking time, cycle time and thermal capacity, using the applicable drive and accessory data.
Design the installation around the drive
Correct selection depends on an installation that supports electrical safety and EMC performance. Separate motor and control cables, keep wiring close to the mounting plate, minimise unnecessary cable length and use a suitable earthing topology. For EMC-compliant installation, use shielded motor cable with appropriate shield connections and connect relevant components to a central earthing point. Cable sizing, fusing, protective-earth connections and filters must be determined for the specific installation and local requirements.
Safety procedures are equally important. Work on an inverter only in a de-energised state, and observe the discharge waiting time specified for the device before touching power terminals. Installation, commissioning and safety functions must follow the applicable product documentation and regulations. Integrated Safe Torque Off (STO), where provided, is a safety function to be incorporated into the machine’s safety design; it does not replace application-specific risk assessment and validation.
Conclusion: make selection a system decision
Sound inverter sizing connects the load profile to the motor, drive, braking arrangement and control-cabinet design. Engineers should verify current and overload requirements, account for environmental correction factors, assess regenerative operation and plan wiring and earthing early. A documented, application-based selection process reduces the risk of choosing a drive that meets the motor’s nominal rating but not the real operating demands.