Access Official Technical PDF

Share Summary:LinkedInEmail

In a multiplexed measurement system, an amplifier must do more than accurately amplify a steady signal. It also needs to respond predictably when an analog input switches between channels. A MUX-friendly operational amplifier can help preserve measurement performance by maintaining high input impedance during these transitions, while combining that behavior with low offset, low drift and fast settling. These characteristics are relevant to industrial instrumentation, analog input modules and other precision signal-conditioning designs.

Why multiplexed inputs challenge precision measurement

Multiplexers let a measurement system connect multiple sources to a shared signal path. When the selected channel changes, the input voltage presented to the amplifier can change rapidly. The circuit then needs time to settle before the next conversion or measurement can be trusted.

Some conventional high-voltage amplifiers use anti-parallel diodes at their inputs to protect internal transistors from large differential voltages. During a channel transition or large input step, those diodes can conduct and load the signal source. That loading can disrupt the input network’s RC settling behavior, extending the time before the signal is stable.

The OPAx189 family—OPA189, OPA2189 and OPA4189—uses a MUX-friendly input architecture intended to avoid this source-loading behavior. The design supports a large input differential voltage while maintaining high input impedance, helping preserve RC settling performance in switched or multiplexed applications. The family also includes a controlled start-up system and ESD protection relevant to handling and assembly.

Precision and noise performance for industrial signals

Offset voltage and its variation with temperature contribute to measurement error, particularly when systems must resolve small signals. The single-channel OPA189 has a typical input offset voltage of ±0.4 µV and a maximum of ±3 µV under the stated electrical-characteristics test conditions. Its typical offset-voltage drift is 0.005 µV/°C, with a specified maximum of ±0.02 µV/°C over the stated temperature range.

Low noise is also important when conditioning signals from sensors such as bridge sensors, thermocouples, current-sensing elements and optical detectors. The specified input voltage noise density is 5.2 nV/√Hz at 1 kHz, and peak-to-peak noise from 0.1 Hz to 10 Hz is 0.1 µV. These figures provide useful design references, but total system noise also depends on the sensor, surrounding circuitry, bandwidth and layout.

For dc accuracy, the device family offers high common-mode rejection and open-loop gain. The data sheet lists up to 168 dB CMRR and 170 dB open-loop gain under specified conditions. Such parameters help characterize how the amplifier responds to common-mode voltage and how closely its closed-loop behavior can follow the intended gain, but they do not remove the need to check operating conditions and system-level error sources.

Balancing settling speed, bandwidth and supply range

Fast settling matters when a system samples channels in sequence: a long recovery interval can limit how quickly the measurement path is ready for the next reading. The OPAx189 specifications include a 20 V/µs slew rate and settling to 0.01% in 1.1 µs for a 10 V step at unity gain with ±18 V supplies. These are test-condition-specific figures, so engineers should compare them with the signal amplitude, gain, load and required accuracy in the actual circuit.

The family operates from a total supply voltage of 4.5 V to 36 V, including single-supply or dual-supply configurations. Its output is rail-to-rail, while the input common-mode range extends to 0.1 V below the negative rail and to 2.5 V below the positive rail under the stated conditions. Rail-to-rail output should not be interpreted as rail-to-rail input capability; designers need to verify that the full input signal remains within the specified common-mode range.

Quiescent current is specified at a maximum of 1.7 mA per amplifier at 25°C, increasing to a maximum of 1.8 mA over the specified temperature range. This makes supply-current budgeting part of the channel-count and power design, particularly when choosing a dual- or quad-channel version.

Design considerations beyond the amplifier

Zero-drift amplifiers use internal switching to correct offset and drift. Brief input bias-current transients associated with this switching can couple through a feedback network and appear as additional output noise. The device guidance identifies a low-pass filter, such as an RC network, as a way to reduce the effect. Filter selection should account for the required bandwidth and the system’s settling needs.

Precision layout also matters. Temperature differences across dissimilar-metal connections can generate thermoelectric voltages that are significant relative to microvolt-level signals. Keep the two input paths thermally balanced, avoid unnecessary dissimilar-metal junctions, and limit temperature gradients from nearby heat sources or airflow. For noisy or high-impedance supply arrangements, local supply decoupling is also recommended.

The OPAx189 includes input EMI filtering, but high-frequency interference can still affect sensitive analog nodes. Shielding and isolation from radio signals, digital clocks and interfaces remain important circuit-level practices. The amplifier is specified for operation from –40°C to +125°C; designers should use the electrical specifications and operating limits relevant to their supply, temperature and load conditions.

Where the architecture can fit

The combination of low offset, low drift, low noise and MUX-friendly input behavior makes the family relevant to precision signal paths in battery test equipment, analog input modules, weigh scales, dc power supplies, ac sources, electronic loads and multifunction relays. The single-, dual- and quad-channel options allow designers to consider channel density and package requirements alongside electrical performance.

Practical implications for system designers

When selecting a precision amplifier for a multiplexed system, assess not only static accuracy but also what happens at the input during channel changes. A MUX-friendly operational amplifier can help avoid input loading that interferes with RC settling, while zero-drift performance and low noise support sensitive measurements. Confirm settling against the real signal path, check common-mode limits and power requirements, and use careful filtering, layout and thermal design to translate device-level performance into reliable system measurements.

Access Official Technical PDF