First Solar Series 2 modules are cadmium telluride (CdTe) thin-film photovoltaic modules described in a September 2006 product document for large, grid-connected solar power plants. For engineers and project teams evaluating this historical specification, the useful questions are how the modules perform under different conditions, what their electrical ratings mean for system design, and which certification and warranty details need verification before use.
The document emphasizes low-light response, temperature behavior, a frameless laminated construction and reliability testing. It also contains an important rating distinction: the stated maximum system voltage is 600 V, while some certification statements refer to testing or certification at 1000 V. These figures should not be treated as interchangeable.
First Solar Series 2 modules: performance characteristics
The product literature presents the Series 2 as an advanced CdTe thin-film design intended to produce energy across a range of climatic conditions. It highlights low-light response and a temperature coefficient for power output as performance characteristics. These details matter during yield assessment because module behavior is not described by nominal power alone; irradiance and temperature conditions also affect output.
The document reports that at an irradiance of 200 W/m², Series 2 module efficiency increases by 2% compared with its efficiency at 1000 W/m². It directs readers to a separate application note for detailed low-light analysis. The material also describes the modules as having a high performance ratio, but provides no supporting project data or calculation method in the supplied specification. Treat that statement as a product claim, not as a guaranteed result for a particular installation.
Electrical ratings and system-design checks
Four model variants are listed: FS-260, FS-262, FS-265 and FS-267. At standard test conditions (STC)—1000 W/m², air mass 1.5 and a cell temperature of 25°C—the listed nominal maximum power ranges from 60 W to 67.5 W, with a stated tolerance of ±5%. The corresponding voltage at maximum power ranges from 62 V to 66 V, while current at maximum power ranges from 0.96 A to 1.02 A.
The datasheet also gives ratings at 800 W/m², 45°C and air mass 1.5. Under those conditions, nominal maximum power is listed from 46.6 W to 49.9 W. These values are condition-specific and should not be compared directly with STC ratings without accounting for the different test conditions.
Other listed electrical specifications include:
- Maximum system voltage: 600 V.
- Power temperature coefficient: -0.25%/°C.
- Open-circuit voltage temperature coefficient: -0.29%/°C.
- Short-circuit current temperature coefficient: +0.04%/°C.
- Maximum source-circuit fuse: 2 A.
For string sizing and equipment selection, designers should use the applicable module documentation and system requirements rather than infer operating limits from certification language alone. The document states that specifications are subject to change and lists ratings with a ±10% qualification, in addition to the nominal power tolerance. The differences between those statements make confirmation against the relevant product record especially important.
Construction, installation and certification
Series 2 uses a frameless laminate with no frame material. The listed assembly consists of 3.2 mm heat-strengthened front glass and 3.2 mm tempered back glass, laminated with EVA encapsulation and an edge seal. The module has 116 active CdS/CdTe semiconductor cells. Listed dimensions are 1200 mm long, 600 mm wide and 6.8 mm thick, with an area of 0.72 m² and a weight of 11.4 kg.
The mechanical description identifies 610 mm leadwires, MultiContact Solar I connectors and no bypass diode. Those are practical details for layout, wiring and installation review. The document also notes that its mechanical drawing is for reference and points readers to a separate document for dimensions and tolerances.
The product literature reports IEC 61646 certification, TÜV Safety Class II and UL recognition, including statements referencing 1000 VDC certification and systems up to 600 VDC. However, its electrical table separately specifies a 600 V maximum system voltage. Project teams should verify the applicable certification scope, system-voltage limit and current documentation rather than assume that a certification test voltage sets the permitted operating voltage.
Warranty and end-of-life planning
The stated warranty includes five years for materials and workmanship. The power-output warranty specifies 90% of nominal output power during the first ten years and 80% during the 25-year period, subject to the warranty terms and conditions. These percentages and periods should be read with the original warranty language; they do not replace review of coverage exclusions, claim procedures or applicable product terms.
The document also describes a reclamation and recycling program with pre-funded end-of-life take-back and recycling for module owners. This provision is relevant to lifecycle planning: procurement and asset-management teams can include module disposition in project records rather than treating it as an unaddressed future task.
Practical implications for PV project teams
First Solar Series 2 modules combine thin-film construction, specified low-light and temperature characteristics, and documented end-of-life provisions. For technical decision-makers, the practical priority is to evaluate the complete specification rather than rely on a single headline feature. Confirm operating limits, ratings, connector requirements, certification scope and warranty terms against authoritative documentation for the exact module and project.
Because this specification dates from 2006 and states that ratings may change, it should be treated as historical product information—not as confirmation of current availability or suitability. Careful document verification is essential before using these figures in system design, procurement or safety reviews.