A rail traction converter is one part of a larger system that turns catenary power into propulsion and onboard auxiliary power. In ABB’s BORDLINE CC1500 AC configuration for regional trains, the traction transformer, modular converter, auxiliary inverters and control platform are designed to work as an integrated traction chain. Understanding how these elements interact helps engineers and fleet decision-makers assess efficiency, availability, maintenance and installation requirements.

How the regional train traction chain works

The system accepts either 15 kV, 16.7 Hz or 25 kV, 50 Hz catenary supply. A traction transformer steps the voltage down before feeding the BORDLINE CC1500 AC Compact Converter, which provides power for the traction motors.

The converter is divided into two parts. Each part drives a traction motor, and the two sections can operate independently. They may use independent control systems or a common system. One section also includes fixed-frequency and variable-frequency auxiliary inverters. This division supports the train-level redundancy concept: the two converter sections are able to work independently, contributing to high system availability.

The described arrangement includes line converters, motor converters, a voltage limiting unit, traction motors and auxiliary inverters. The transformer and converter must be considered together because converter characteristics affect transformer design as well as the electrical supply delivered to the motors.

Rail traction converter design and energy efficiency

The BORDLINE CC1500 AC is a compact, modular propulsion converter using low-voltage IGBT technology. Its design combines a patented multilevel converter topology with high switching frequency. According to the product information, this switching approach enables optimization of the traction transformer, including the use of a super-efficient, low-impedance dry-type transformer, and reduces traction motor losses, audible noise and mechanical stress.

A further element is the “Best Efficiency Control” algorithm. Rather than applying one fixed operating strategy across all conditions, the control seeks an energy-efficient operating point for each operating condition. For rail operators, this illustrates why converter efficiency is not determined only by power electronics: control behavior and the interaction between converter, transformer and motor also matter.

The product documentation specifies propulsion output of 2 × 1050 kW at the wheel. It also lists a power density of 1.7 MW/t. These figures describe the stated configuration and should be considered alongside the complete vehicle design and its operating requirements.

Auxiliary power and output quality

Auxiliary converters draw power from the intermediate DC link and generate current-limited three-phase outputs. The HBU provides fixed-frequency output, while the HWR provides variable-frequency output for the converter and transformer cooling system. The listed auxiliary converter output is 3 × 400 V at 50 Hz and 140 kVA; the auxiliary inverter output is 3 × 80–480 V at 10–60 Hz and 32 kVA.

Sine filters reduce switching-frequency ripple current, so the resulting output is described as nearly free of high-frequency components. This filtering is relevant to the quality of power supplied to auxiliary equipment. The system’s grid-friendly line converter and motor-friendly voltage quality are also identified as design features, with the latter intended to minimize additional motor losses.

Control, cooling and maintainability

Control and diagnostics

The traction converters use ABB’s AC 800 PEC control platform for traction-related control and protection, diagnostics, and interfacing with the vehicle control unit. Modular visual programming is intended to support adaptation of the control software. The vehicle control interface specified for the system is TRDP.

BORDLINE View provides a way to visualize signals, parameters and traction-system status. The described self-diagnostic function offers guidance for service and repair. Digital connectivity also supports operation-data and condition monitoring beyond the traction chain, including information related to wheel and rail, pantograph and catenary conditions.

Thermal and mechanical design

Service water cools the power modules. An internal air-to-water heat exchanger transfers internal losses to the outside ambient, helping avoid hot spots and keep internal air temperature close to coolant temperature. The product information links this thermal approach to the reliability of the control electronics.

The converter is housed in a roof-mounted, vibration-resistant IP65 cabinet, with roof, machine-room and underfloor installation variants listed. Its modular subsystems use lightweight modules and spill-free quick couplings, allowing maintenance without special tools. The stated dimensions are 1812 × 746 × 1976 mm, and the converter weight is 1295 kg. The associated Resibloc Rail dry-type traction transformer is specified as a roof-mounted, air-cooled unit with 1300 kVA continuous power.

Practical considerations for fleet and engineering teams

When assessing a regional train traction chain, teams should look beyond converter ratings. The system architecture, transformer interaction, auxiliary loads, cooling method, mounting location, control interface and service access all affect integration and lifecycle planning. The independent converter sections are relevant to availability planning, while the modular construction and diagnostic tools are relevant to maintenance workflows.

ABB identifies the BORDLINE CC1500 AC as used in FLIRT and KISS trains for several operators. That application information provides context for the intended regional-train use, but installation choices and operating results depend on the specific vehicle and configuration.

Conclusion

A rail traction converter delivers the most value as part of a coordinated traction chain. In this design, converter topology and control are linked to transformer optimization and motor performance, while auxiliary inverters supply onboard needs and the control, cooling and mechanical systems support operation and servicing. For technical decision-makers, evaluating these interfaces together is essential to judging whether a traction system fits the vehicle’s power, installation, availability and maintenance requirements.