Industrial backup power depends on more than selecting an energy storage device. Batteries and ultracapacitors must be kept at appropriate energy levels so they can help protect critical processes when an outage or voltage sag occurs. A battery and capacitor charger supports this readiness by maintaining stored energy and, where required, can also operate as a DC power supply.
In an industrial setting, that function matters wherever an interruption can affect production equipment or process continuity. The Bonitron M5628 is an isolated charger designed for batteries and capacitors. Its adjustable charge voltage and current limit, status contacts and digital display provide tools for managing charging and monitoring the charger.
Why energy storage needs a dedicated charger
Energy storage devices provide a reserve for systems that need protection from power disturbances. But the reserve is useful only when the storage device is maintained at an appropriate energy level. A charger supplies the energy needed to keep batteries or ultracapacitors ready for their intended role in a backup-power arrangement.
This is particularly relevant to uninterruptible power for drives (UPD). In a UPD system, energy storage can help a variable frequency drive ride through a power disturbance. The M5628 is described as a charger for the batteries or capacitors used in these kinds of energy-storage applications. It can also be used as a DC supply, giving system designers another potential role for the unit within an electrical system.
Battery and capacitor charger features for system integration
Charger selection and integration involve more than matching a power source to an energy storage device. Operators and integrators also need a way to configure charging and understand the charger’s operating condition. The M5628 includes several features intended to support those tasks:
- Adjustable current limit and charge voltage: These adjustments allow charging parameters to be set for the application.
- Digital display: A backlit LCD shows the charger’s current status and provides access to other screens and user-selected actions.
- Fault records: The display can record unit faults, providing information that can help with troubleshooting.
- Isolated status contacts: These contacts provide status information for connection to a wider control or monitoring arrangement.
For maintenance and operations teams, visibility into charger status is an important part of managing an energy-storage system. A display that communicates operating status and records faults can make relevant information available at the unit. Isolated status contacts offer a separate means of incorporating charger status into system-level monitoring, depending on the overall design.
Matching the charger to the application
The M5628 product range includes several model configurations, with maximum charge currents of 5 A or 20 A and different physical dimensions. The published input range is 208–506 VAC at 50–60 Hz. Model selection should account for the installation and the requirements of the connected energy-storage arrangement, including the required charging current and available mounting space.
Energy storage options described for UPD applications include both ultracapacitors and batteries. The M3528UC ultracapacitor module is used to help prevent power sags and outages for variable frequency drives. Within a UPD system, it is described as providing full outage protection for up to two seconds. The M3528B battery bank is intended to provide emergency power during outages; multiple units can be connected for higher voltages and longer outage protection.
These examples illustrate why charger decisions should be considered as part of the broader backup-power design. The storage technology, drive system, protection objective and charger configuration all need to work together. The charger maintains the energy reservoir; the selected battery or ultracapacitor arrangement provides the stored energy for the application.
Where industrial backup power can matter
Applications identified for these solutions include critical data systems, elevators, extrusion, fiber production, semiconductor manufacturing, solar power, textiles and wind power. Across these settings, the common consideration is protecting a critical process or drive system from power fluctuations. A suitable backup arrangement can help limit equipment damage and support uptime, though the results depend on the system design and application requirements.
For plant engineers and system integrators, practical evaluation should include the nature of the power disturbance to be addressed, the energy storage device, the required charging settings and how status information will be used. Those details help determine whether the charger’s available current, voltage adjustment, display and contacts fit the intended installation.
Conclusion: treat charging as part of the backup-power design
Batteries and ultracapacitors can support industrial processes during power disturbances, but their readiness depends on maintaining stored energy. An isolated battery and capacitor charger such as the M5628 is designed to perform that charging role, with adjustable settings and features for viewing status and faults. Evaluating the charger alongside the storage device and the wider UPD or backup-power system helps ensure that each component is selected for its part in protecting critical operations.