Access Official Technical PDF

Share Summary:LinkedInEmail

Reliable CAN bus protection helps preserve the transceiver interface when electrostatic discharge (ESD) or other transient surge events reach a network’s data lines. In 24 V designs, a transient voltage suppressor (TVS) array can provide a path to clamp these events before they damage the transceiver. The onsemi SZ/NUP3125 is a dual-line protection device intended for CAN applications, including industrial control networks and automotive systems.

Its compact SC-70 (SOT-323) package contains bidirectional protection for both CAN data lines. Understanding how the device responds to transients—and how its ratings relate to the application—helps engineers integrate protection without treating a headline power rating as a substitute for system-level design.

How CAN bus protection works

A surge protection diode presents high impedance during normal operation and low impedance when the voltage rises above its breakdown region. During a transient, the device conducts and clamps the voltage, helping limit the stress seen by the connected CAN transceiver. A surge-rated Zener TVS is designed to absorb the high peak energy of a transient; this differs from a standard Zener diode, which is designed and specified for steady-state voltage regulation.

The SZ/NUP3125 uses a bidirectional diode arrangement on each data line. In the circuit described in the device documentation, the effective clamp consists of a reverse-biased diode’s breakdown voltage plus the forward drop of another diode. The dual-line arrangement supports protection of CAN_H and CAN_L with one small package.

SZ/NUP3125 characteristics for CAN transceiver protection

The device is specified for 24 V designs and has a 32 V reverse working voltage (VRWM). This is the maximum continuous peak reverse voltage for which the device is intended to remain in its working region. When selecting a TVS protector, the working voltage should be equal to or greater than the system’s DC or continuous peak operating voltage, as stated in the data sheet. Engineers should therefore confirm the actual line conditions before choosing a protection component.

Other listed electrical characteristics help frame the design trade-offs:

  • Breakdown voltage: 35.6 V minimum and 39 V typical, measured at a 1 mA test current.
  • Clamping voltage: 47 V typical and 55 V maximum at a 1 A, 8/20 μs pulse; 57 V typical and 60 V maximum at 2 A under the same waveform.
  • Maximum peak pulse current: 2.0 A for the specified 8/20 μs waveform.
  • Capacitance: 5.7 pF typical at 0 V and 1 MHz, line to ground; it is 4.5 pF typical at 5 V under the stated test conditions.
  • Leakage: no more than 100 nA at a 32 V reverse working voltage.

The data sheet also lists 120 W peak power dissipation per line for an 8/20 μs double-exponential waveform. This rating and the electrical table’s peak-current and clamping figures describe specified test conditions; they should not be interpreted as a guarantee against every possible transient. The product’s stated maximum ratings include an operating junction temperature range of −55°C to 150°C.

Matching and compliance considerations

For a differential network, keeping the protection characteristics of the two data-line paths closely matched is relevant to the interface design. The SZ/NUP3125 specifies diode capacitance matching of 0.26% typical and 2% maximum, measured at 0 V and 5 MHz. Its listed capacitance values and matching figures should be considered alongside the requirements of the CAN transceiver and network.

The device lists compatibility with IEC 61000-4-2 ESD Level 4, IEC 61000-4-4 electrical fast transient testing at 50 A (5/50 ns), and IEC 61000-4-5 surge testing at 2.0 A (8/20 μs). These are component-level ratings under defined test conditions. A system’s immunity depends on its complete design and installation, so product-level test compatibility should not be treated as proof that an assembled network meets a particular compliance requirement.

Applications and package options

Target applications include high- and low-speed CAN, CAN FD, fault-tolerant CAN, automotive networks and trucks. Industrial applications listed for the device include Smart Distribution Systems (SDS) and DeviceNet. The SC-70 package offers a compact implementation for designs where board space is a consideration.

The SZ prefix identifies versions intended for automotive and other applications requiring unique site and control change requirements; the data sheet states that these versions are AEC-Q101 qualified and PPAP capable. The listed devices are lead-free, halogen-free/BFR-free and RoHS compliant. Ordering status matters: the data sheet marks the NUP3125 ordering parts as discontinued, while listing SZNUP3125WTT1G and SZNUP3125WTT3G in SC-70 tape-and-reel options. Confirm current availability with the supplier before specifying a part.

Practical design checks

When evaluating this or any CAN protection device, engineers and integrators should verify that the working voltage suits the normal bus conditions and that the clamping characteristics are compatible with the transceiver’s limits. Check the relevant pulse waveform and current ratings rather than relying on a single peak-power figure. Also assess line capacitance and matching, package and layout needs, and the applicable system-level immunity tests.

CAN bus protection is most effective when the device ratings are understood in context: the normal operating voltage, the transient conditions the system must withstand, and the interface’s electrical requirements all matter. The SZ/NUP3125 offers dual-line TVS protection in a compact package for specified 24 V CAN applications, but final component selection and system validation remain essential to a robust industrial or automotive network.