Access Official Technical PDF

Share Summary:LinkedInEmail

Solar irradiance and wind availability vary over time, so a renewable energy system built around either source alone may not consistently match load demand. A hybrid solar-wind system can draw on both sources, with a battery included in the modeled configuration to support energy availability. A key control challenge is extracting power as operating conditions change. The proposed design addresses this through fuzzy logic MPPT (maximum power point tracking), converter stages and a grid-connected microgrid architecture evaluated in MATLAB/Simulink.

Why combine solar and wind generation?

Photovoltaic output depends on sunlight, while wind generation depends on wind conditions. When one resource is weak or unavailable, the other may still contribute. Combining the sources therefore provides an alternative to relying on a single renewable input, although it does not make generation constant by itself. The system still needs to manage variable power and provide a suitable electrical output for the connected load or grid.

In the proposed arrangement, photovoltaic generation is paired with a wind turbine driving a permanent magnet synchronous generator (PMSG). The two sources feed a shared power-conversion system, with a battery bank included in the simulated hybrid configuration. The design is intended to extract power from the available sources and condition it for use by a microgrid.

How fuzzy logic MPPT fits into the system

Maximum power point tracking adjusts a source-side operating point to extract available power as conditions change. The paper uses a fuzzy logic controller (FLC) for this task. Unlike a fixed operating setting, fuzzy logic uses defined rules to respond to changing input conditions; in the model, the controller generates switching pulses for the boost-converter stage.

The implementation uses a Mamdani fuzzy inference system. Its role is to guide MPPT operation for the hybrid generation arrangement, rather than to eliminate the variability inherent in solar irradiance and wind speed. The control method is assessed through simulation, so the reported behavior describes the modeled system and should not be treated as a field performance guarantee.

Power conversion from renewable sources to the microgrid

Power from the PV and wind subsystems is routed through an interleaved boost converter. A boost converter raises DC voltage; an interleaved design uses multiple switching paths. The paper notes that this arrangement can reduce input and output current ripple compared with a single-channel boost topology, while also acknowledging that additional semiconductor switches introduce switching and conduction losses.

The FLC-based MPPT controller supplies pulses to the converter switches. The resulting DC output is then converted to AC by an inverter. The inverter uses pulse-width modulation (PWM) to control its semiconductor devices, and the system description also identifies a Z-source inverter with PI control as part of the proposed grid-coupling arrangement. Together, these stages connect renewable generation to a DC link and then to AC loads or the grid.

The model represents the solar array using a mathematical PV model whose output responds to solar irradiance and temperature inputs. On the wind side, the turbine drives a PMSG. Turbine power depends on factors including swept blade area, wind speed, air density and the turbine power coefficient. These source models provide the variable inputs that the converter and control stages must handle.

What the MATLAB/Simulink cases show

The paper evaluates three simulated operating cases: hybrid generation with a battery, wind generation with a battery and no PV input, and PV generation with a battery and no wind input. The comparisons illustrate how the modeled system behaves when both sources contribute and when only one renewable source is available.

  • Hybrid case: PV and wind outputs feed the shared conversion system, which boosts the DC voltage before inverter conversion.
  • Wind-only case: The wind subsystem supplies the DC link when PV generation is absent.
  • PV-only case: The PV subsystem supplies the DC link when wind generation is absent.

In the reported hybrid simulation, the boosted voltage is shown at about 400 V DC in the narrative, while the results table lists 600 V for boosted voltage and AC output. The wind-only and PV-only cases also report different output levels. These results demonstrate the model’s operating scenarios, but the variation between reported values means they should be read in the context of the specific simulation configuration rather than as a single general system rating.

Engineering considerations for implementation

For engineers and system integrators, the architecture highlights several decisions that need to be coordinated: how each source is modeled, how MPPT responds to changing conditions, how the DC link is regulated, and how the inverter interfaces with the load or grid. Battery integration is part of the modeled arrangement, but the source does not detail a battery-management strategy or operating limits.

Simulation is useful for examining control behavior and comparing source-availability cases before hardware deployment. However, results depend on model assumptions, component parameters and control settings. Before applying the design to a plant or microgrid, teams would need to validate the intended operating range, converter and inverter configuration, protection requirements and grid-interface behavior for their specific application.

Conclusion

The proposed hybrid system combines PV generation and a PMSG-based wind subsystem with fuzzy logic MPPT, an interleaved boost converter and inverter-based AC conversion. Its MATLAB/Simulink cases illustrate how the architecture can process combined or single-source inputs. The practical takeaway is that combining renewable sources is only part of the design: control, voltage conversion and grid or load interfacing must work together, and simulation results require application-specific validation before they inform implementation decisions.

Access Official Technical PDF

About The Author