Groundwater remediation at industrial sites is rarely a single-system challenge. At two adjoining former semiconductor manufacturing facilities in Santa Clara County, California, volatile organic compounds (VOCs) released from historical operations created a shared groundwater plume. A 2018 five-year review found that contamination had declined and the selected remedy was progressing, while also identifying monitoring and long-term protection measures that needed attention.
The review covered the National Semiconductor Corporation and Monolithic Memories Superfund sites. Its findings offer a practical example of how groundwater treatment, institutional controls, and vapor intrusion evaluations work together when contaminated groundwater remains beneath active commercial and industrial areas.
Why the two sites were reviewed together
The sites are adjacent, and their solvent plumes have commingled. The review therefore assessed them as three subunits: the former National Semiconductor campus, the former Monolithic Memories properties, and the downgradient area where contamination from the source areas overlaps.
Past manufacturing activities affected soil, soil vapor, and groundwater. The contaminants included chlorinated solvents and aromatic compounds. Indicator compounds used to assess groundwater contamination included trichloroethene (TCE), 1,1,1-trichloroethane, cis-1,2-dichloroethene, 1,1-dichloroethene, and Freon 113. Other contaminants, including benzene, xylenes, polycyclic aromatic hydrocarbons, and phenols, were also identified.
The principal concern was not limited to conditions at the former facilities. The sites overlie the Santa Clara Valley groundwater basin, a regional water resource. The remedy was designed to reduce contaminant concentrations, limit plume migration, address contaminated soil, and prevent exposure while cleanup continued.
Groundwater remediation combines treatment and controls
The 1991 Record of Decision established a remedy that included groundwater extraction, treatment by air stripping or ozone oxidation, and discharge of treated water under permits. Soil vapor extraction or soil excavation was also specified where needed. Institutional controls were intended to restrict groundwater use and manage activities that could pose risks to health or the environment.
By the time of the 2018 review, two groundwater extraction and treatment systems were operating: the On-Site system in the southern part of the former National Semiconductor campus and the Lakeside system in the downgradient area. Extracted groundwater was treated using air stripping and ozone technologies before permitted discharge.
A third system, the Arques system, had been offline since September 2016 following a leak in its untreated-water conveyance line. The review noted that declining downgradient concentrations and the system’s age were factors in not restarting it; the Regional Water Board approved continued shutdown in January 2018. This illustrates why system status should be assessed alongside plume trends, infrastructure condition, and the remedy’s overall objectives—not in isolation.
Other treatment approaches were used at source areas. These included soil vapor extraction, excavation of impacted soil, chemical oxidation using persulfate, and bioremediation. At the Monolithic Memories property, a separate PCE spill in 2005 prompted soil removal and multi-phase extraction. The treatment system was later shut down with regulatory approval after mass removal reached an asymptotic condition, and the review reported that no soil concentrations above the applicable cleanup goals were known to remain there.
Vapor intrusion requires ongoing attention
Groundwater VOCs can be relevant to indoor air when vapors migrate through soil and enter buildings. The review described vapor intrusion assessments at buildings across portions of the sites and noted that mitigation measures had been implemented where warranted. It also emphasized that such measures were not required by the original remedy, creating a potential gap in long-term oversight.
To strengthen continued protection, the review recommended considering changes to incorporate existing mitigation systems, require vapor intrusion evaluation and mitigation where appropriate, and establish long-term monitoring plans for buildings that had been mitigated or could face future unacceptable exposure.
The Monolithic Memories area presented a specific monitoring concern because a children’s daycare was near elevated TCE concentrations in groundwater and soil vapor. Earlier indoor-air sampling, including the two most recent events identified in the review, had not indicated unacceptable vapor intrusion risk. However, those events took place in June 2012, and nearby groundwater and soil-vapor concentrations remained elevated. The review recommended confirmatory sampling and a long-term indoor-air monitoring program, with the possibility of adjusting monitoring frequency based on results.
Monitoring and institutional controls are part of the remedy
The review found that land-use restrictions and groundwater-use covenants remained important safeguards. They restricted groundwater use as a drinking-water source and limited residential use on specified properties. Drinking water for residences and businesses in the downgradient area was supplied by the City of Santa Clara, according to the report.
Monitoring also needed to be complete and consistent. The review flagged three wells near the 2005 PCE spill area that had not been sampled since the previous review, despite Regional Water Board direction. For site teams, this is a reminder that a treatment strategy depends on reliable monitoring data to evaluate trends, verify assumptions, and identify emerging issues. Missing measurements can weaken the evidence used to support operational or regulatory decisions.
Practical implications for industrial site teams
The 2018 review concluded that the remedy was progressing toward its objectives: groundwater contaminant concentrations had been significantly reduced and continued to decrease, and soil source areas had been addressed. It found the remedies protective because potential exposure pathways were being controlled and institutional controls restricted land and groundwater use. At the same time, it identified steps needed to support long-term protection.
- Assess treatment-system changes in context. Review plume behavior, capture objectives, equipment condition, and regulatory approvals when a system is taken offline or modified.
- Maintain a complete monitoring program. Track required wells and indoor-air sampling so decisions rely on current, representative data.
- Connect groundwater and building assessments. Evaluate vapor intrusion where buildings overlie or are near VOC-affected groundwater, with particular care around sensitive populations.
- Keep controls and mitigation visible. Document land-use restrictions, existing mitigation systems, and ongoing inspection or monitoring responsibilities.
For industrial automation and operations leaders, the broader lesson is that remediation performance depends on more than treatment equipment. Groundwater extraction, soil and vapor interventions, institutional controls, and building monitoring must operate as a coordinated program. Sustained oversight—and clear action when monitoring gaps or changing site conditions emerge—helps preserve the protections established by the remedy.