High-voltage semiconductor testing is essential when engineers evaluate silicon carbide (SiC) and gallium nitride (GaN) devices for power conversion and other demanding applications. These wide-bandgap technologies can support designs that push beyond silicon’s performance in power density and efficiency, but they also bring characterization challenges. Engineers must measure high reverse voltages while detecting very small currents—and ensure the test system protects people from hazardous voltage.

For research, qualification, and manufacturing teams, a well-planned test combines appropriate source-measure equipment, careful low-current measurement practices, and a properly interlocked enclosure. Two core measurements are breakdown voltage and reverse leakage current.

Why SiC and GaN characterization needs care

SiC and GaN devices are not simple drop-in replacements for silicon components. Their electrical characteristics affect device design, gate-drive requirements, and the way engineers validate performance. SiC devices may require higher gate voltages and negative bias for turn-off, while GaN devices have lower threshold voltages that call for tightly controlled gate-drive designs. Wide-bandgap devices also have a higher body-diode voltage drop, making dead-time and switching transitions important design considerations.

These requirements make accurate measurements valuable early in development. Reliable data can help teams make design decisions without relying unnecessarily on wider margins or overdesign. At the same time, some tests involve voltages above 200 V, so measurement quality and operator safety must be considered together.

High-voltage semiconductor testing: breakdown and leakage

Measuring breakdown voltage

A breakdown voltage test applies an increasing reverse voltage to a device until the current reaches a defined test level indicating breakdown. For a high-voltage diode, the source-measure unit (SMU) is connected to the cathode to apply reverse bias, while it sources voltage and measures current.

Qualification testing may extend beyond a device’s expected rating to assess its robustness. The voltage capability needed depends on the device and test objective. The Keithley 2470 SourceMeter SMU, for example, can source up to 1,100 V, a range described for testing many current and future SiC and GaN device designs. Select test limits and connections for the specific device and procedure; do not treat an instrument’s maximum output as a routine test target.

Measuring reverse leakage current

In a power-conversion circuit, a semiconductor switch should block current when it is off. Reverse leakage measurements help assess how closely a device behaves like an ideal switch. They can also be used to monitor degradation and support device-lifetime assessments.

Leakage current may be very small even when the device is under substantial reverse voltage. The 2470 specifies measurement resolution as low as 10 fA, but achieving meaningful low-current results also depends on the test setup. When measuring below 1 µA, triaxial cables and electrostatic shielding help reduce unwanted current and noise. The triax guard routes system leakage away from the measurement terminal, while a conductive shield around the circuit and exposed connections helps divert electrostatic charges.

Build safety into the test fixture

High-voltage protection should be part of the system design, not an afterthought. Enclose the device under test and exposed connections in a properly grounded fixture. Use cables and connectors rated for the maximum voltage in the setup, and wear appropriate safety gloves when working with energized high-voltage components.

An interlock adds a further safeguard by disabling the high-voltage output when the fixture is open. In the example test arrangement, a normally open switch is connected to the SMU’s interlock circuit and closes only when the access point is secured. A lid-operated relay can therefore interrupt the interlock if the cover is removed. Follow the instrument and fixture instructions when implementing this protection; an interlock does not replace safe work practices.

Set up a repeatable leakage-current sweep

A software-guided test can make it easier to configure a voltage sweep, view results, and repeat measurements. In the documented SiC rectifier example, the device’s specified maximum reverse current is 100 µA at 1,000 V and room temperature. The test uses a linear reverse-voltage sweep with these settings:

  • Start at −20 V and stop at −1,000 V, with −5 V steps.
  • Set the current limit to 1 µA and the measurement range to 1 µA.
  • Use a 1 kV source range, a measurement speed of 1 NPLC, and Auto Zero enabled.
  • Connect through the instrument’s rear inputs using high-voltage triax connections.

With the device secured in an interlocked fixture, KickStart software’s IV Characterizer app can run and plot the sweep. The example results show the diode meeting its specification, with reverse current increasing more rapidly as voltage approaches the region of breakdown. Plot zooming helps inspect that change, while saved data and screenshots support review and comparison. These tools help organize the measurement; engineers still need to interpret results against the device specification and test conditions.

Practical implications for engineering teams

Characterizing SiC and GaN devices requires more than applying a voltage and recording current. Test teams need to choose suitable source and measurement ranges, control leakage and electrostatic interference, and verify that cables, fixtures, and interlocks are appropriate for the voltage involved. Clear, repeatable sweeps can then provide useful evidence about breakdown behavior and reverse leakage during development or qualification.

The practical takeaway is to treat measurement accuracy and safety as connected parts of the same test plan. An SMU capable of sourcing high voltage and measuring low current, paired with guarded connections, shielding, a grounded enclosure, and an effective interlock, provides a structured approach to evaluating high-voltage power devices.