ICT environmental management is not limited to reducing electricity use in a server room. Data centres, telecommunications networks, end-user devices and software are connected parts of a service system, each with potential impacts from energy and water consumption to equipment use and electronic waste. For industrial operators and technical decision-makers, the practical challenge is to manage these impacts together rather than optimise one asset in isolation.
A European Commission Joint Research Centre report on best environmental management practices for the telecommunications and ICT services sector groups relevant measures across organisations, data centres, networks and software. Its central lesson is useful beyond ICT providers: establish a way to assess performance, then apply measures at the stages where an organisation can influence design, procurement, operation and end-of-life decisions.
Build an environmental management framework
An environmental management system (EMS) can provide a repeatable structure for identifying significant impacts, setting priorities and tracking progress. The approach described in the report includes benchmarking existing use and measuring and monitoring environmental performance. That matters because improvement depends on understanding where resources are consumed and which activities the organisation can control or influence.
For an industrial business, this can mean considering both its own ICT infrastructure and the services it buys. A data centre operator, for example, can directly manage facility equipment and operating practices. A customer using hosted services may have less control over the facility but can include environmental criteria in service procurement. In either case, indicators help connect management decisions to observable performance.
Improve data centre energy management
Data centres bring together servers, storage, network equipment, power systems and cooling. Their environmental performance therefore depends on the interaction between IT workloads and supporting infrastructure. The report identifies several complementary practices for existing facilities:
- Measure and manage energy use. An energy management system for a data centre includes measuring, monitoring and managing both ICT and other equipment.
- Set data management and storage policies. Clear policies can guide how data is managed and stored, helping operators address demand for storage and processing.
- Manage airflow and cooling. Airflow design, cooling management and appropriate temperature and humidity settings are operational areas for review.
These measures should be considered as a system. Changes to cooling, for instance, should not be assessed only by their electricity implications. The report highlights potential trade-offs, including water use associated with some cooling approaches and the resource and embodied-energy implications of replacing equipment. An integrated assessment can help avoid shifting burdens from one environmental aspect to another.
Consider environmental impacts before new builds and upgrades
Planning decisions can shape a data centre’s operating requirements for years. The report recommends considering environmental aspects during planning and design, including the building layout, the location of cooling equipment, and opportunities to reuse waste heat. It also identifies location as a factor that can affect opportunities for waste heat reuse, renewable energy and free cooling. Alternative water sources are another practice to consider where relevant.
Capacity planning is part of this environmental picture. The report notes that data centres can be over-dimensioned to accommodate operational or capacity changes, which can contribute to inefficiency. Planning that accounts for actual needs and future requirements can help avoid designing infrastructure around unnecessary tolerances, while still recognising the facility’s service requirements.
Apply lifecycle thinking to ICT procurement
Procurement decisions influence both the equipment an organisation buys and the services it relies on. Sustainable ICT procurement involves developing environmental criteria and applying them through the procurement process. For data centres, equipment choices may include servers, storage and network interfaces as well as power and cooling systems.
Purchasing decisions should consider more than the energy consumption of an individual device. The report emphasises balancing energy use with water use, resource efficiency and embodied energy. It also identifies extending equipment service life through maintenance and controls, and improving collection and sorting at end of life, as ways to support resource efficiency through waste prevention, reuse and recycling.
End-user devices deserve attention too. Organisations can optimise their energy consumption through technical measures in installation, configuration and use. The report also stresses that organisational support matters: staff acceptance and senior management commitment can help technical changes take hold.
Manage network energy and infrastructure impacts
Telecommunications networks have their own operational and infrastructure considerations. Better energy management starts with improved knowledge of network consumption. The report describes measures to reduce traffic peaks that can drive network oversizing, and to reduce energy use during periods of low or moderate traffic. Equipment selection, site design and software settings can also contribute to network energy management.
Upgrades are an opportunity to review existing sites and equipment. When technology transitions occur, operators can assess whether unused equipment can be decommissioned and whether power and cooling supply arrangements need adjustment. Construction and renovation decisions also affect environmental performance: the report identifies co-location and appropriate choices about location and equipment as ways to address land use, visual impacts and noise.
It also treats electromagnetic fields as a risk-management and transparency issue. Assessment and transparency of data are presented as practices for addressing public concern, alongside the relevant regulatory context—not as a substitute for compliance.
Use software and ICT to support wider improvements
Software influences the volume of data processed and transmitted, and therefore the demands placed on hardware. Green software practices aim to minimise data traffic and associated hardware energy consumption. The report applies this idea to new and existing software, including applications, web portals and computer software.
ICT can also help other sectors improve their environmental performance—a concept described as “greening by ICT.” This is distinct from reducing the footprint of ICT operations themselves. For industrial organisations, it encourages consideration of how telecommunications and digital services may support environmental improvements in areas such as manufacturing, buildings, transport and energy systems, while assessing benefits in the relevant application rather than assuming them.
Turn practices into an operational improvement plan
The practices are not a one-size-fits-all checklist. Their relevance depends on the organisation, its assets and the lifecycle stages it can influence. A practical starting point is to establish an environmental baseline, identify significant impacts, and select measures that fit operational requirements. Track implementation with suitable indicators, review trade-offs such as energy versus water use, and revisit priorities as equipment and services change.
For industrial automation and operations leaders, the implication is straightforward: ICT infrastructure should be managed as part of the wider environmental performance system. Monitoring, careful procurement, efficient operation, lifecycle planning and software optimisation offer connected opportunities to reduce impacts. Applying them systematically helps technical teams make decisions that account for the whole service—not just the most visible piece of equipment.