Industrial cable selection is a design decision that affects power supply, control signals and data communication across machines and plants. A cable must suit both the electrical task and the conditions along its route. Matching the cable to its intended use helps reduce the risk of damage associated with mechanical stress, electrical conditions, ageing, corrosion or unsuitable installation.

For engineers, system integrators and operations teams, the selection process begins with a clear description of the application. From there, voltage, routing, movement, environmental exposure and standards can guide the choice of cable construction and accessories.

Start with the cable’s function

Cables and conductors provide a path for electrical energy or transmit information between equipment. The first question is therefore what the cable must carry: power, control signals, data or a combination of functions in a system. This distinction helps narrow the cable group and informs decisions about conductor construction, insulation and shielding.

It is also important to understand the parts of a cable. The conductor carries current; its insulation provides electrical separation. In a multicore cable, insulated conductors are commonly twisted or laid together as a cable core. A sheath protects the underlying components from external influences. Depending on the application, shielding or other protective elements may also be included.

Industrial cable selection: key criteria

Electrical requirements

Establish the required rated voltage, commonly expressed as U0/U, and identify the cable’s electrical function. Conductor material and construction matter too. Copper is widely used, while aluminium is another conductor material. Conductors may be solid or stranded, with stranded versions available in constructions suited to different flexibility requirements.

Conductor cross-section and length affect electrical resistance: resistance decreases as cross-section increases and rises as conductor length increases. Cable selection should account for the application’s electrical requirements rather than relying on a product label or a single dimension in isolation.

Installation and movement

Determine whether the cable will remain fixed or move during operation. A stationary installation has different mechanical demands from a cable in a drag chain, a robot or another moving machine section. For dynamic applications, consider the minimum bending radius and the expected movement, including repeated bending or torsion where relevant. The cable must be selected and installed according to the conditions for which it was designed.

Routing also affects the assessment. Cables installed in open or enclosed systems may have different requirements, including consideration of current-carrying capacity and applicable reduction factors. Nearby electromagnetic interference (EMI) sources can also influence whether a shielded construction is needed.

Environmental exposure

Assess the conditions the cable will encounter over its service route. Relevant influences include heat or cold, ultraviolet radiation, weather, moisture, oils, acids, alkalis, solvents and abrasion. The sheath material should be appropriate to the expected exposure; commonly used sheath materials include PVC, PUR, silicone rubber and chloroprene rubber. No single material is suitable for every environment, so selection should follow the specific application requirements.

Mechanical hazards also deserve attention. Bending, pulling, twisting, impact and abrasion can affect cable integrity. Where additional protection or guidance is required, protective systems such as conduits, hoses or energy chains may form part of the installation design.

When shielding and identification matter

Shielding can serve different purposes. A steel wire braid can provide mechanical protection, while a copper wire braid can help with electromagnetic compatibility (EMC). Other constructions may use copper wrapping or a metallised foil. The appropriate approach depends on whether the primary concern is physical protection, electromagnetic disturbance or both.

For multicore cables, conductor identification supports correct wiring and maintenance. Cores may be identified by colour or by numbers printed on the insulation. The protective earth conductor is identified green and yellow in the systems described in the guide. Always verify the applicable identification requirements for the installation.

Check standards and additional requirements

Before finalising a specification, identify the standards and approvals required for the destination market and application. The guide cites examples such as VDE, HAR, UL, CSA and NOM. These requirements can relate to cable construction and intended use, and should be confirmed as part of project design and procurement.

Other project requirements may include flame behaviour, halogen-free construction, oil or chemical resistance, abrasion resistance, resistance to torsion, or restrictions on substances that can affect processes such as paint wetting. These are not universal requirements; they should be included when the installation or operating environment calls for them.

A practical specification workflow

  1. Describe the application: identify whether the cable carries power, control signals or data, and which equipment it connects.
  2. Set electrical requirements: define rated voltage and consider conductor construction, cross-section and route length.
  3. Map the installation: record whether the cable is fixed or moving, its routing system and any bending or torsion demands.
  4. Review exposure: identify thermal, chemical, mechanical and physical conditions along the route.
  5. Assess interference and protection: determine whether shielding or additional mechanical protection is needed.
  6. Confirm compliance: check applicable standards, approvals and any project-specific material or fire requirements.

Conclusion

Reliable industrial cable selection depends on matching cable construction to the complete application—not just its electrical function. A structured review of voltage, conductor characteristics, movement, routing, environmental exposure, shielding and standards gives technical teams a clearer basis for specifying cables and accessories. Checking these factors before installation helps ensure the chosen cable is appropriate for the operating conditions it is expected to face.