Access Official Technical PDF

Share Summary:LinkedInEmail

A pulsed power generator must charge energy-storage components and then deliver that energy to a load in a short, controlled burst. A hybrid architecture that combines a Marx generator with a capacitor diode voltage multiplier (CDVM) offers one way to manage both functions. The multiplier charges capacitors from a comparatively low input voltage, while Marx-style switching connects the charged outputs in series to produce a high-voltage pulse.

The approach is relevant to engineers evaluating solid-state pulsed power for applications such as water and air treatment, food processing, medical systems, and other processes that use pulsed electric fields. Its modular structure also provides design flexibility: output voltage depends on the input supply, multiplier stages, and number of modules.

Why combine a Marx generator and voltage multiplier?

A conventional Marx generator charges capacitors in parallel and discharges them in series. This arrangement allows the stored capacitor voltages to add at the load. However, charging the capacitors to the required voltage can be a significant part of pulsed-power system design. A capacitor charging system must reach the target voltage within the available time while accounting for component ratings and losses.

A CDVM addresses voltage multiplication by charging capacitors through diodes in a staged circuit. Yet, in many multiplier arrangements, increasing the number of stages also increases voltage stress on components, limiting how far the design can be extended.

The hybrid topology assigns complementary roles to the two structures. CDVM modules raise the voltage stored on their output capacitors; Marx switching then connects those capacitor outputs in series for the discharge. This division of work supports a modular converter, rather than relying only on a longer multiplier chain to obtain a higher pulse voltage.

How the modular pulsed power generator operates

The proposed system consists of an input supply, an AC-DC converter where required, a full-bridge converter, multiple voltage-multiplier modules, charging and pulsing switches, and a controller. The AC-DC and full-bridge stages can be omitted in some configurations, but doing so limits control of output voltage and makes higher output frequency more difficult to achieve.

Charging the multiplier modules

During charging, the charging switches are closed and the pulsing switches remain open. The full-bridge converter applies voltage to the multiplier modules, and their capacitors charge through the diode-capacitor networks. In the analyzed two-module, one-stage example, an inductor forms a resonant circuit with the multiplier capacitors. The converter can switch at zero inductor current (zero-current switching, or ZCS), reducing switching stress in this part of the circuit.

The charging process uses successive resonant intervals. First, a pair of capacitors charges; then diode conduction changes the effective resonant circuit so that the other capacitors can charge further. The sequence repeats until the module output capacitors reach their intended voltage. This resonant operation is central to the example circuit’s charging behavior.

Discharging into the load

When the capacitors are charged, the charging switches open and the pulsing switches close. The module output capacitors are then connected in series, and their voltages add across the load. In the two-module, one-stage example, each output reaches four times the DC input voltage under ideal conditions, producing a combined output of eight times the input voltage.

More generally, the ideal maximum output voltage described for the topology is proportional to the number of modules, the number of multiplier stages, and the input voltage: Vload = 4mnVdc, where m is the number of modules and n is the number of multiplier stages. This relationship describes the topology’s idealized maximum; actual output is affected by non-ideal component behavior.

Design factors for output voltage and repetition rate

Modularity provides choices, but each choice affects electrical ratings and timing. The output voltage is determined by the input voltage, multiplier stage count, number of modules, and control of the full-bridge converter. The voltage rating of each module’s output capacitor and the discharge switches also constrains the design.

For a resistive load, the design can begin with the pulse energy requirement. The energy stored in the output capacitance is related to the effective capacitance and the square of the output voltage. This relationship helps engineers select capacitance based on the required pulse voltage and energy, while recognizing that practical operation may not discharge all stored energy in the same way.

Repetition rate depends on the time needed to recharge, the pulse duration, and any required delay between pulses. The charging interval is influenced by the resonant inductance and capacitance. Consequently, choices made to meet pulse energy and voltage targets also affect how quickly the system can deliver successive pulses.

Losses also require attention. Switch and diode losses include conduction and switching components; off-state losses may be neglected in the analysis. ZCS makes switching losses in the full-bridge switches negligible in the described operating modes, but conduction losses remain. The Marx discharge switch has its own switching and conduction losses. Component selection and thermal design therefore need to reflect the intended operating conditions.

What simulation and prototype results demonstrate

MATLAB/Simulink simulation of the two-module example shows the inductor current returning to zero at switching transitions, consistent with ZCS operation. The simulated module output capacitors reach four times the DC input voltage, and their combined voltage forms the pulse at the load.

A low-voltage experimental prototype was also tested. With a 28 V input, measured capacitor voltages reached approximately 104 V, and the load pulse was approximately eight times the input voltage. The measured result differed from the ideal value by about 8.5%, attributed to non-ideal characteristics including diode forward voltage, switch saturation voltage, and element resistance. These results validate operation of the example at low voltage; they are not, by themselves, a demonstration of a high-voltage industrial installation.

Practical implications for system designers

The hybrid Marx-CDVM approach offers a way to separate voltage multiplication from series pulse formation. For engineers considering this architecture, the main design questions include:

  • How many modules and multiplier stages are needed to meet the target pulse voltage?
  • Are capacitor and switch voltage ratings appropriate for each module and the discharge sequence?
  • Can the charging time, pulse duration, and delay support the required repetition rate?
  • Have conduction losses and non-ideal voltage drops been included in the expected output?
  • For higher-voltage designs, are isolated or optocoupler drivers and isolated control power supplies required?

The proposed design can be extended with additional modules or stages, but increasing the number of Marx stages also makes coordinated switch operation important. The study describes bypass diodes as a way to provide a path if a Marx switch does not turn on as intended. Such protection and isolation measures should be treated as part of the system design, not as optional details.

Conclusion

A modular pulsed power generator combining a Marx arrangement with capacitor-diode voltage multipliers uses the multiplier to charge module capacitors and series switching to create the output pulse. Its architecture allows output voltage to be adjusted through module count, multiplier stages, and input conditions, while resonant charging can support zero-current switching in the full-bridge stage. For practical projects, the key is to balance voltage and energy targets against component ratings, recharge time, losses, switch coordination, and electrical isolation. Simulation and low-voltage prototype results support the operating principle, while application-specific design and validation remain essential.

Access Official Technical PDF

About The Author