Access Official Technical PDF

Share Summary:LinkedInEmail

Mono PERC solar modules were a central focus of LONGi’s 2018 technology roadmap, which connected cell architecture and module design with energy yield and levelized cost of energy (LCOE). For engineers and project decision-makers, the useful question is not simply whether a module has a higher rated power. It is how its behavior under operating conditions, system configuration and site characteristics may influence lifetime energy production and project economics.

The roadmap described the company’s products and development priorities at that time. Its performance figures and field observations should be read in that historical context, not as guarantees for other projects or as a statement of current product specifications.

How mono PERC fits into solar module design

PERC stands for passivated emitter and rear cell. In a conventional cell, the rear surface includes a passivation layer and a rear-side structure. LONGi’s presentation contrasted that design with bifacial PERC, which uses rear contacts that allow the cell to collect light from both sides. The front-side efficiency was described as equivalent to conventional PERC, while the rear-side design enables additional energy capture when reflected or scattered light reaches the back of the module.

That distinction matters in system design. A conventional monofacial module primarily converts light arriving at the front. A bifacial module can also use light reaching its rear surface, so the potential benefit depends on the installation—not solely on the module. Ground reflection, module height, tilt, spacing and surrounding conditions affect how much rear-side irradiance is available.

What the roadmap reported about mono PERC solar modules

LONGi’s 2018 material presented low light-induced degradation (LID) as one of the features of its Hi-MO1 mono PERC product. It also cited low-light performance and temperature behavior as factors that could contribute to energy production. The presentation reported average production-cell efficiency above 21.2% and a next-generation cell record of 23.60% in December 2017. For modules, it reported production power above 300 W for 60-cell modules and a 333.7 W development record in January 2018.

These are figures from the company’s dated presentation, not universal benchmarks. Rated power and cell efficiency are useful comparison points, but they do not alone determine a system’s annual output. Operating temperature, irradiance, orientation, shading, inverter configuration and other site and system factors also matter.

Energy yield: interpreting test and field data

The roadmap included several types of evidence, each with a different scope. It described a TUV Rheinland energy-yield simulation using module performance measurements under varying irradiance, temperature and incident angle, with simulated results across five cities. The presentation explicitly noted that the simulation was not a performance guarantee.

It also reported a comparison in Sanya, China, from October 2016 to August 2017. In that setup, Hi-MO1 PERC modules were compared with multi-crystalline modules, and the reported average energy-yield increase was 3.93%. LONGi attributed potential differences to low-irradiance response, operating temperature and temperature coefficient. The material cited different maximum-power temperature coefficients for the compared module types, but results from one climate and system configuration should not be assumed to transfer directly to another site.

For project evaluation, engineers should distinguish among laboratory measurements, simulations and monitored field results. Each answers a different question. A simulation can help compare modeled conditions; monitoring shows performance in a particular installation; neither removes the need to assess the proposed project’s actual design and environment.

Bifacial PERC and the importance of system configuration

LONGi’s Hi-MO2 roadmap described bifacial PERC cells and modules, including double-glass construction and a stated bifaciality above 75%. The presentation discussed rear-side power gain and showed predicted module output at different assumed bifacial gains. Those values were modeled scenarios, not a promise that a project will achieve a specific gain.

The company also reported project monitoring results: a three-month installation in Pucheng recorded 11.27% energy yield from the rear side, while a demonstration using bifacial modules on a single-axis tracker was reported to generate 14.3% more power than a multi-crystalline tracker comparison. These results involved specific sites and configurations. They illustrate why bifacial module selection cannot be separated from mounting and balance-of-system decisions.

When assessing a bifacial design, project teams should examine whether the layout exposes the rear surface to useful light and how tracker or fixed-tilt choices, ground clearance and site conditions affect that exposure. The value of added rear-side generation must be considered alongside the system design required to capture it.

Connecting module performance to LCOE

The practical objective is not maximum module efficiency in isolation, but an energy system that meets project requirements at an appropriate cost. Higher lifetime energy production can support lower LCOE, but the outcome depends on both energy delivered and total project costs. LONGi’s roadmap positioned mono PERC—including bifacial PERC—as a route toward lower LCOE by combining cell improvements with module and system-level yield opportunities.

For technical and commercial reviews, compare modules using consistent assumptions. Consider rated power, degradation and warranty terms, temperature and low-light behavior, reliability-test information, and the expected site-specific energy yield. For bifacial options, include the planned mounting arrangement and rear-side conditions in the analysis. Treat manufacturer simulations and field examples as inputs to due diligence rather than substitutes for project-specific modeling.

Conclusion

LONGi’s 2018 roadmap shows how mono PERC development linked cell structure, module design and system conditions to energy-yield objectives. Bifacial technology adds another design variable: the rear side can contribute energy, but only when the installation provides suitable light exposure. For engineers, integrators and project owners, the key implication is to evaluate module performance in the context of the complete photovoltaic system—and to interpret reported results according to their test method, location and configuration.

Access Official Technical PDF

About The Author