Radiation detection electronics for silicon strip detectors must do more than register that a particle has arrived. They need to capture information related to particle energy and timing, associate measurements with the correct detector channel, and move useful data into downstream acquisition equipment. HINP5, a 16-channel application-specific integrated circuit (ASIC) developed for low- and intermediate-energy nuclear physics experiments, brings these tasks together through analog signal-processing paths and digital configuration and readout logic.
Its architecture offers a useful example of how channel-level measurement circuits can work alongside shared control logic and external data-acquisition hardware. The design is intended for systems using silicon strip detectors, where channel identity, energy measurement and arrival time all contribute to interpreting a detection event.
How HINP5 processes detector signals
A silicon strip detector is a reverse-biased diode. When ionizing radiation or a charged particle interacts with its detection material, it generates electron-hole pairs. The resulting charge packet is related to the energy deposited by the particle. In a strip array, the responding detector elements also help identify the position of the interaction.
Each HINP5 signal channel processes an input from a detector or an external preamplifier. The channel includes a charge amplifier, slow shapers, peak samplers, timing circuitry and digital readout functions. The charge amplifier provides high- and low-gain paths, with gains of four and one respectively. The corresponding shaper paths have stated linear ranges of 100 MeV for high gain and 400 MeV for low gain. Peak samplers capture the shaped signals for digitization by external analog-to-digital converters (ADCs).
The two gain paths allow the system to represent signals across different energy ranges. HINP5 supports positive and negative pulse polarities, with signal conditioning arranged to accommodate the peak samplers’ response to negative peaks. Its timing branch provides a separate measurement path, rather than relying on the energy readout alone.
Timing and channel identification
For timing, a constant fraction discriminator (CFD) produces a logic signal associated with a particle’s arrival. The channel’s time-to-voltage converter (TVC) starts from this timing signal and stops when it receives a shared external time reference. The resulting voltage represents the interval between the channel event and that reference. The design provides selectable TVC full-scale ranges of 250 nanoseconds and 2 microseconds.
The CFD uses discriminator stages to establish the timing decision. In the described architecture, a leading-edge discriminator qualifies the zero-crossing discriminator output. This approach is intended to make the timing signal less dependent on particle energy than a simple threshold crossing would be.
HINP5 sends three analog measurement outputs for digitization: the high-gain pulse height, the low-gain pulse height and the TVC voltage. Digitally encoded channel addresses are synchronized with these outputs so that the acquisition system can associate each digitized value with its originating channel.
Shared configuration and readout logic
Alongside its 16 signal channels, HINP5 has a central common channel containing control logic and circuits shared across the chip. Three 8-bit configuration registers provide settings for functions such as the TVC range, selected operating modes, Nowlin timing parameters, signal-ground adjustment and channel selection. Each signal channel also has a 6-bit digital-to-analog converter (DAC) register used to set the threshold for its CFD.
Configuration is performed through an address and data interface. The external controller supplies data on an 8-bit bidirectional bus, while control signals determine whether the information is directed to configuration registers or channel DAC registers. This separates chip-wide settings from per-channel threshold programming.
The digital design was described in Verilog and implemented using a 0.35-micron standard-cell library. The design flow included simulation, logic synthesis, place and route, and electrical-level validation after transfer into custom IC tools. Using standard cells provides reusable, library-based logic building blocks and makes it easier to revise the digital design than creating every logic element as a full-custom layout.
Sparse readout and reset behavior
Readout efficiency is another important part of the architecture. HINP5 supports data sparsification: channels do not have to be read out in a fixed sequence regardless of activity. A channel records a hit, and control logic can identify active channels for acquisition. An OR output indicates whether at least one channel remains to be read out, while a multiplicity output provides an analog indication of the number of hit channels.
Each channel also has an auto-reset function. A programmable delay determines how long a hit can remain pending; if readout is not initiated within that interval, the channel resets itself. This behavior helps prevent an unserviced event from leaving channel circuitry occupied indefinitely. The design also supports externally controlled reset and channel enabling, allowing the larger acquisition system to coordinate the ASIC’s operation.
From ASIC outputs to the acquisition system
In the described system, chipboards contain two HINP5 devices, an FPGA and ADCs. The ADCs digitize the analog energy and timing outputs locally, and the FPGA manages chip configuration and data acquisition. Digitized measurements and channel information are then transferred to a motherboard and onward through the system.
This division of work is significant: HINP5 performs front-end signal processing and identifies which channels need attention, while external electronics handle conversion, control and data movement. The result is a coordinated measurement chain rather than a standalone detector chip.
Practical implications for system designers
HINP5 illustrates several considerations for engineers integrating multichannel detector electronics:
- Plan the full signal chain. Analog pulse outputs, ADC inputs, channel addresses and timing references must be treated as related parts of the acquisition design.
- Configure by function. Shared registers and per-channel DAC settings serve different purposes and should be managed accordingly by the controller.
- Account for event handling. Sparse readout, OR status and programmable auto-reset behavior affect how the FPGA schedules acquisition and recovers channels.
- Validate digital logic in context. Simulation and implementation checks help verify not only the logic description but also its synthesized and placed forms before integration with analog circuitry.
For systems based on silicon strip detectors, the practical value of a multichannel ASIC depends on how well measurement, timing, control and readout work together. HINP5 combines separate energy and timing paths with per-channel thresholds, shared configuration, channel-status signaling and automatic reset. Understanding these interactions helps system integrators and detector designers plan the interfaces between the sensor, ASIC, ADC, FPGA and higher-level acquisition hardware.