In a black phosphorus FET, the metal-semiconductor contact can strongly influence measured transistor behavior. The Schottky barrier height (SBH)—the energy barrier carriers encounter as they move between a metal and semiconductor—is therefore an important parameter for evaluating contact performance. But extracting it from electrical measurements is not always straightforward: gate hysteresis can distort the result, and carrier-injection mechanisms change with operating conditions.
Temperature-dependent measurements of titanium-contact black phosphorus devices illustrate why the extraction method matters. Conventional thermionic-emission analysis produced a substantially lower barrier estimate than band-alignment calculations. A modified method based on contact resistance, with measurements selected to reduce hysteresis and field-emission effects, provided a different estimate and highlighted the possible role of titanium oxide at the interface.
Why contacts matter in black phosphorus FETs
Black phosphorus (BP) is a layered semiconductor with a tunable direct band gap and the potential for relatively high carrier mobility. In a transistor, however, material properties alone do not determine current flow. The metal contacts affect how easily carriers enter the BP channel, and a contact barrier can influence output characteristics, on-current and extracted mobility.
The metal’s work function helps determine the barrier alignment. A high-work-function metal can favor hole injection into p-type BP, while a lower-work-function metal can favor electron injection. These are general tendencies rather than a complete description of a fabricated contact: interface conditions and the device’s operating regime also matter. Measuring the SBH helps engineers assess the contact’s contribution to device behavior.
Using thermionic emission to extract Schottky barrier height
Carrier injection across a metal-semiconductor junction can involve thermionic emission (TE), in which carriers pass over the barrier, and field emission (FE), in which they tunnel through it. Thermionic-field emission (TFE) can also contribute. The balance among these mechanisms depends on conditions such as gate bias and temperature.
In the subthreshold region, where the study observed thermionic-emission behavior, current measurements at different temperatures can be analyzed using an Arrhenius plot. The slope provides an activation energy. As gate voltage changes, the BP energy bands bend, changing the activation energy for hole injection. Near the flat-band condition, this activation energy corresponds to the Schottky barrier height used in the analysis.
The method has a limitation: when the device is driven further into its on-state, tunneling contributions from TFE and FE can increase. A TE-only analysis of current under those conditions may then underestimate the barrier because it attributes the measured injection to thermionic emission alone.
How gate hysteresis affects the measurement
In the reported Ti-contact BP FET measurements, the transfer curve shifted with temperature. Part of the shift was associated with thermionic emission, but charge trapping at the BP/SiO2 interface and in the dielectric also contributed. The resulting hysteresis was more pronounced at higher temperatures and was nearly negligible at 80 K in the measured device.
Hysteresis matters because it changes the apparent threshold voltage depending on gate-sweep direction. If temperature-dependent current is compared without accounting for that shift, current in the subthreshold region can be higher than expected from thermionic emission alone. The resulting activation energy, and therefore the extracted SBH, can be too low.
For the device studied, the conventional activation-energy approach gave an SBH of 51.5 meV at a drain-source voltage of −0.4 V. Extrapolating measurements at different drain-source voltages to zero bias to account for image-force barrier lowering gave 58.2 meV. The authors identified hysteresis as a reason this estimate was below the value expected from theoretical band alignment.
Contact resistance offers a complementary approach
A modified extraction method uses contact resistance rather than relying on the drain current alone. Contact resistance was measured using a transfer length method (TLM) structure, with comparisons made at the same gate overdrive—the gate voltage relative to the threshold voltage. Matching the overdrive helps reduce the impact of a temperature-dependent threshold shift on the comparison.
For thermionic-emission-dominated contact resistance, its temperature dependence can be analyzed through a plot of ln(RcT0.5) against inverse temperature. The slope is used to estimate the barrier. This approach also avoids the simplifying assumption that all drain-source voltage drops at the metal-semiconductor contact.
Choosing the temperature range is essential. In the measurements, contact resistance decreased as temperature rose in the lower-temperature range, consistent with thermionic emission. Above about 170 K, phonon scattering affected the device’s intrinsic mobility and contributed to the temperature dependence of resistance. The researchers therefore extracted the SBH using measurements from 80 K to 170 K, at a gate overdrive of −60 V. This method yielded an estimate of 325 meV.
Interpreting the different barrier estimates
The study also estimated the BP band gap from the temperature dependence of the minimum current in the ambipolar transfer curve. The extracted value was 0.418 eV, consistent with the theoretical range cited for BP of the device’s thickness. Applying the Schottky–Mott rule to the estimated band alignment of titanium and BP gave a theoretical hole barrier of 0.228 eV.
These values are not identical measurements of an uncomplicated interface. The activation-energy result was considered underestimated because of hysteresis, while the contact-resistance method gave a higher effective barrier. Transmission electron microscopy and energy-dispersive X-ray spectroscopy indicated oxygen in the deposited titanium region. The authors proposed that partial titanium oxidation could create an additional barrier for hole injection, helping explain why the effective contact-resistance estimate exceeded the theoretical band-alignment value. They also noted that oxidation and BP preparation could vary between samples.
Practical implications for device characterization
For engineers and device researchers evaluating 2D-material transistors, the results underline the need to treat SBH extraction as a measurement problem, not just a calculation. A practical analysis should:
- Identify the injection regime. Check whether thermionic emission dominates or whether tunneling mechanisms may affect the result.
- Track gate-sweep direction and hysteresis. Threshold-voltage shifts can alter temperature-dependent current comparisons.
- Account for temperature-dependent transport. Scattering can affect resistance independently of the contact barrier.
- Use complementary evidence. Compare electrical extraction with band-alignment estimates and, where available, interface characterization.
No single extracted value should be interpreted without its measurement conditions and assumptions. For the Ti-BP devices discussed here, contact resistance provided a useful alternative to conventional activation-energy analysis, while interface evidence suggested a possible contribution from titanium oxide. Together, these considerations help explain why measured contact behavior can differ from an idealized metal-semiconductor alignment—and why careful characterization is essential when developing and comparing BP FETs.