Water is both a process input and an operational risk for semiconductor manufacturers. In a 2019 testimony on water security, Intel described how its fabs use water for cooling and ultra-pure water (UPW) for wafer cleaning and rinsing. The account offers a practical view of semiconductor water management: improve efficiency inside the facility, recover water where possible, and consider how operations affect the wider watershed.
For plant managers and engineering teams, the central challenge is that production demand and local water conditions are connected. Manufacturing complexity can increase water requirements, while the water available to a site depends on its location and community infrastructure. A resilient approach therefore extends beyond reducing water use per process step.
Why semiconductor manufacturing needs water
Some fab water use resembles that of other industrial facilities, particularly water used for cooling. Semiconductor manufacturing also requires substantial quantities of UPW in cleaning and rinsing operations. As wafers move through multiple stages to form circuits, water is used to remove residue, including residue associated with chemical-mechanical polishing.
UPW is treated to remove organic and inorganic contaminants so it can be used in sensitive manufacturing steps. The process complexity described in Intel’s testimony—including the addition of multiple layers of circuitry—means that water is required repeatedly as production advances. This makes water availability a direct operational concern for a manufacturer that owns and runs its production facilities, rather than only a supplier or procurement issue.
Semiconductor water management: reuse and recovery
Intel reported that its onsite water practices returned approximately 80% of the water it used to communities for reuse or groundwater recharge. The remaining portion was described as water consumed within operations, primarily through evaporation in cooling towers or uptake by landscaping. This distinction matters when assessing a facility’s water balance: water discharged or reused is not the same as water consumed onsite.
In Chandler, Arizona, Intel built the Ocotillo Brine Reduction Facility, a reverse-osmosis treatment operation designed to process 1.5 million gallons of water daily for aquifer recharge or community reuse. The City of Chandler owns and operates the facility, while Intel provides operations and maintenance funding. The testimony reported that more than 5.1 billion gallons had been recharged to the local aquifer since the facility began operating.
Intel also described plans for a treatment facility at a newer Arizona factory to process wastewater for additional onsite reuse, and a water recycling facility at its Ronler Acres campus in Oregon. These examples illustrate several implementation considerations for industrial teams:
- Identify recovery opportunities: Map where process and wastewater streams can be treated for reuse or recharge.
- Account for consumed water: Include evaporation and other losses when evaluating the facility water balance.
- Coordinate ownership and operations: Water infrastructure may involve shared responsibilities between a manufacturer and a local utility or community.
- Assess the local context: Water availability and watershed needs differ between sites, so a single facility strategy may not suit every location.
From facility efficiency to watershed restoration
Water reuse can reduce demand on local supplies, but it does not eliminate the broader watershed challenge. Intel’s 2019 testimony said the company had set a goal to restore 100% of the water it used globally by 2025, combining internal management practices with investment in community-based water projects. This was a stated commitment and target in the testimony, not evidence here of the goal’s eventual completion.
In Arizona, the company described funding projects with conservation and nonprofit partners intended to restore water to the environment. The projected benefits were quantified by a third party and were to be reported annually. For industrial decision-makers, this approach highlights the importance of defining what “restoration” means, selecting projects that address local water issues, and establishing a method to measure and communicate outcomes.
Such partnerships can complement onsite efficiency and reuse, but they serve a different purpose. Facility projects change how water is managed within or around operations; watershed projects aim to support water resources and communities beyond the facility boundary. Clear accounting helps organizations distinguish these contributions rather than treating them as interchangeable.
Digital tools for water security and quality
The testimony also discussed information technology applications that could support water management. These ideas extend the industrial automation toolkit beyond the plant: sensors, data systems and analytical methods can help monitor water conditions, improve forecasts and inform decisions across a basin.
Monitoring, forecasting and allocation
Artificial intelligence was identified as a possible tool for improving basin modeling and forecasting. Sensor networks can provide more timely information about hydrologic systems, while sensors at customer taps may support improved tracking and metering of use and, eventually, real-time water-quality monitoring. The testimony also raised blockchain as a potential means of enabling peer-to-peer water trading. These are described as possible applications, not guaranteed outcomes; their value depends on how they are designed and applied.
Connecting water quantity with water quality
Digital approaches can also help target conservation and pollution-control efforts. The testimony cited remote sensing, geographic information systems and cloud computing as tools for mapping where water flows from land into waterways. Better spatial information can help locate buffers and other practices where they may have the greatest effect. It also described stream-temperature monitoring used to support temperature trading, in which verified reductions associated with streamside tree planting could provide an alternative to installing cooling infrastructure at upstream industrial plants.
Precision agriculture provides another example of the link between water quantity and quality. Remote sensing combined with in-field sensors can help farmers assess soil moisture and crop health, supporting irrigation decisions about when and how much water to apply. More targeted fertilizer and pesticide use may also reduce the amount carried into receiving waters.
Practical implications for industrial operators
Semiconductor water management is not limited to treatment equipment or a single efficiency metric. It requires understanding process demand, distinguishing reuse from consumption, evaluating site-level infrastructure and considering the condition of the watershed that supplies the facility. Digital monitoring and analysis may strengthen decisions, while community and conservation partnerships can extend efforts beyond the plant boundary.
For manufacturers and system integrators, the practical takeaway is to treat water as a managed operational resource. Build a clear water balance, identify feasible recovery and reuse streams, and connect facility planning with local water conditions. Where digital tools are considered, define the management question they need to answer and how results will be verified. Combining these measures can help organizations address water security while supporting reliable operations and the communities that share the resource.