Choosing a graphite material for semiconductor or photovoltaic equipment requires more than checking a single strength or temperature-related figure. Engineers need to consider a set of physical, mechanical, electrical and thermal properties, and understand how representative data relates to the block or format being specified. SIGRAFINE R6140 graphite is an isostatically pressed material identified for semiconductor and photovoltaic applications. Its published data provides a useful starting point for evaluation, but not a substitute for application-specific engineering review.
SIGRAFINE R6140 graphite: material and application context
SIGRAFINE R6140 is described as graphite formed by isostatic pressing. The technical data sheet lists semiconductor and photovoltaics as its application areas. It does not identify particular equipment, process steps or operating conditions, so material selection should be based on the requirements of the intended component rather than on the application category alone.
The listed values are typical averages from different rectangular and round block sizes. The manufacturer notes that individual block values may vary with dimension and format. This distinction matters during design: a typical value is a reference for assessing a material, not a guarantee that every supplied piece will have exactly the same properties.
Key physical and structural properties
The data sheet reports an average grain size of 150 µm and a bulk density of 1.56 g/cm³. These figures describe aspects of the material’s structure and mass per unit volume. They can help engineers compare candidate materials and frame component-level evaluations, but they should be considered alongside the full property set and the dimensions of the proposed part.
Porosity-related data is also provided. Open porosity is listed as 24 Vol.%, while the medium pore entrance diameter is 14 µm. The coefficient of permeability at ambient temperature is 16 cm²/s. Together, these measurements characterize aspects of the pore network and gas permeability. Their relevance depends on the conditions and function of the specific component; the figures alone do not establish suitability for a particular process.
Mechanical, electrical and thermal data
For mechanical evaluation, the listed flexural strength is 11 MPa and compressive strength is 25 MPa. The dynamic modulus of elasticity is reported as 5 × 10³ MPa. These values describe different aspects of mechanical response: flexural and compressive strength relate to behavior under specified loading modes, while the modulus indicates stiffness under dynamic measurement. They are not interchangeable, and design checks should use the property that corresponds to the component’s loading and support conditions.
Electrical resistivity is reported as 15 µΩm. Thermal conductivity at 20 °C is 65 Wm⁻¹K⁻¹, and the coefficient of thermal expansion over 20–200 °C is 2 × 10⁻⁶ K⁻¹. These properties are especially relevant when assessing electrical behavior, heat transfer and dimensional change over the stated temperature interval. The figures should be applied within their stated measurement conditions; the data sheet does not provide a complete performance profile across other temperatures or operating environments.
Ash content is listed as 200 ppm. This is a material-composition measure that may be relevant when defining cleanliness or material constraints for an application. The published figure should be treated as a typical value, not as a specification for every individual block unless confirmed for the required supply.
How to use the typical values in engineering
For a preliminary review, engineers can map the published data against the component’s functional requirements. For example, a design assessment may consider whether the reported strength values are relevant to the expected loading, whether thermal conductivity and expansion fit the thermal design, and whether resistivity and ash content align with electrical or material requirements.
A practical review should also distinguish between:
- Measured property and design limit: A typical material value is not automatically an allowable design value or acceptance criterion.
- Test condition and operating condition: Some data is tied to a stated temperature or test standard. Avoid assuming the same value applies under different conditions.
- General material data and individual block data: The published averages may differ from the values of a specific block, particularly as dimensions and format vary.
These distinctions help prevent a datasheet from being used beyond what it establishes. Where a design depends on a particular property or tolerance, the required value and verification approach should be discussed with the supplier’s technical sales team.
Confirming suitability for a specific application
The data sheet explicitly cautions that its information reflects the supplier’s present state of knowledge and is intended as general guidance. It does not guarantee specific product properties or suitability for a particular use. It also directs customers to contact technical sales for engineering or design purposes.
Accordingly, SIGRAFINE R6140 can be considered using its published typical profile, but final material selection requires confirmation against the component design, operating conditions and applicable requirements. Engineers should verify which properties are critical, clarify any necessary block-specific information, and observe relevant industrial property rights and purchasing conditions.
Conclusion
SIGRAFINE R6140 is an isostatically pressed graphite listed for semiconductor and photovoltaic applications, with published typical data spanning structure, permeability, strength, electrical resistivity, thermal behavior and ash content. The figures provide a basis for technical screening, not a universal guarantee of performance. For engineering decisions, the practical priority is to match the relevant measured properties to the application and confirm requirements for the specific block or format with the supplier.