As transistor dimensions shrink and device architectures become more complex, understanding conditions inside the channel becomes increasingly important. Local electric fields and strain influence carrier mobility, yet conventional measurements may offer only a two-dimensional view, require destructive sample preparation, or lack the resolution needed for transistor-scale analysis. Single erbium ion sensing offers a different route: using changes in an individual ion’s optical spectrum to probe its immediate environment.
Experiments in silicon FinFETs demonstrated that single erbium ions respond to applied electric fields and strain. The measured strain precision was better than 3 × 10-6. Combined with a proposed method for locating individual ions, the approach could support three-dimensional mapping within ultra-scaled transistor channels. It is an emerging metrology technique, rather than a completed mapping system, and its practical use depends on further calibration and development.
Why transistor channels need local metrology
In scaled CMOS devices, small changes in the channel environment can affect transistor behavior. Strain can influence carrier mobility, while electric fields arise from device bias and from local charge configurations. As geometries become more intricate, process variation can also make it harder to predict device properties using simulations alone.
Existing measurement methods involve trade-offs. Electron microscopy techniques can provide high spatial resolution, but typically require thin specimens and return a two-dimensional projection, making the analysis destructive. Optical and X-ray methods can offer less damaging or three-dimensional measurements, but their spatial resolution may be insufficient for detailed channel-level characterization. Surface probe techniques can improve lateral resolution but are generally limited to surfaces or shallow regions.
A sensor embedded in the semiconductor could help address some of these limitations. Erbium ions are optically responsive to their surroundings, and their spectra can shift as local electric fields or lattice strain change. Measuring those shifts offers a way to investigate conditions at the ion’s location rather than infer them solely from a device-level signal.
How single erbium ion sensing works
The approach relies on the interaction between an Er3+ ion and its local environment. Electric fields and strain alter the energy levels associated with the ion’s optical transition, producing a Stark shift: a change in the transition frequency. By measuring the shift and interpreting it with an appropriate physical model, researchers can estimate the electric field or strain around the ion.
In the reported experiment, a silicon FinFET was operated at 4.2 K under conditions that allowed it to function as a single-electron transistor (SET). Quantum dots in the channel produced Coulomb-blockade features in the current as gate voltage changed. When a tunable laser matched an erbium ion’s optical transition, the ion could be photo-ionized. The resulting change in the charge environment shifted the SET signal, allowing the optical spectrum to be recorded through an electrical measurement.
This hybrid optical-electrical readout is important because the ion’s response is detected through the transistor itself. The experiment resolved spectral responses from individual ions and tracked how their transition frequencies changed as device voltages and applied strain were varied.
What the electric-field measurements revealed
Changing the source-drain voltage produced a monotonic, approximately linear shift in the optical transition frequencies of two measured ions. This response is consistent with sensitivity to the electric field along the channel. The researchers used a simplified model to estimate Stark coefficients, while noting that a more uniform field in a specially designed device would be needed for more accurate characterization.
Gate-voltage measurements showed that the response can depend on more than the overall applied field. One ion exhibited a much larger frequency shift than the other across the measured gate-voltage range. Abrupt spectral changes as the device moved between Coulomb peaks were attributed to changes in the local charge configuration of quantum dots. In other words, the ions responded to both the broader device field and local electric-field changes associated with charge rearrangement.
That distinction matters for device analysis. A nominal voltage or simulated field may not fully describe the conditions near a particular location in a channel. A local probe could provide experimental information about those variations, although converting spectral data into quantitative field values requires knowledge of the ion’s site and a suitable model.
Strain sensitivity and the path to three-dimensional maps
To test strain response, the sample was attached to a piezoelectric actuator. Applying voltage to the actuator generated biaxial strain in the plane of the device. The spectral shifts of two ions changed linearly over the tested strain range, with measured sensitivities of 3.8 and 5.1 MHz per 10-6 strain. Based on peak stability and those sensitivities, the estimated strain measurement precision was approximately 2.9 × 10-6 for one ion and 1.6 × 10-6 for the other.
To build a spatial map, each ion’s position must also be determined. The proposed method uses a magnetic-field gradient and the ion’s optical Zeeman response, following a principle similar to magnetic resonance imaging. The work estimated that a sufficiently strong gradient could enable localization at around 1 nm. This is a projected capability, not a demonstrated three-dimensional map of a transistor channel.
With ion locations and calibrated spectral responses, measurements across many nominally identical devices could be used to assemble statistical three-dimensional maps and examine device-to-device variation. Such an approach could complement simulation and existing microscopy, especially where internal fields and strain are difficult to access directly.
Engineering considerations before implementation
Several factors affect how readily the technique can be applied. Erbium can occupy different sites in silicon, and ions with similar site symmetry may still have different spectral properties. Accurate extraction of strain and electric field therefore requires calibration and consideration of the ion’s local structure. The reported strain measurements were made at cryogenic temperatures, so translating results to operating conditions would require accounting for temperature-dependent lattice behavior.
Introducing ions also needs careful control. Erbium implantation can create defects and may perturb the local lattice. The researchers propose using the minimum required ion dose and an appropriate annealing strategy to limit excess defects. These considerations make sensor placement, material preparation, and device design part of the metrology challenge.
Practical implications for semiconductor development
Single erbium ion sensing demonstrates a way to turn an optically active atomic-scale impurity into a local probe within silicon. Its key promise is the combination of high strain sensitivity, access to electric-field changes, and a potential route to three-dimensional localization. For engineers and process teams, the approach could eventually provide measurements that help validate models and reveal local variations inside complex transistor channels.
Realizing that potential will require more than detecting spectral shifts: ion sites must be characterized, the field and strain response calibrated, and spatial localization integrated into a reliable workflow. The experimental results establish a foundation for that work. If these steps can be addressed, rare-earth ions may become a useful complement to established semiconductor metrology techniques for investigating the internal conditions of ultra-scaled devices.