Industrial controllers often need to preserve data through a power interruption while continuing to update it during normal operation. Event records, operating values and other frequently changing information can put pressure on conventional nonvolatile memory, where write delays or limited write endurance may affect system design. SPI F-RAM offers an alternative: it retains data without power while accepting reads and writes through a serial peripheral interface at bus speed. The FM25C160B illustrates how this approach can serve applications such as industrial control and data collection.

Why SPI F-RAM suits frequent updates

The FM25C160B is a 16-Kbit ferroelectric random access memory, organized as 2,048 locations of eight bits each. It is accessed as an SPI slave, using a master-controlled clock and chip-select signal. Its memory operation is broadly similar to serial flash and EEPROM, but its write behavior is different: data is written to the array as it is transferred, rather than waiting for a separate programming cycle to finish.

With serial flash or EEPROM, a host may need to account for internal write time and, in some cases, check whether the device is ready before starting another operation. The FM25C160B does not require that write-completion polling. After a byte has been transferred successfully, the next bus transaction can proceed. This makes writes effectively synchronous with the SPI bus and avoids the additional delay associated with waiting for a write cycle.

That difference matters when a controller must capture changing data promptly. If a system depends on completing a write before another event arrives or before power is removed, the memory’s write behavior is part of the overall design—not just a component-level detail. F-RAM can reduce the time spent managing nonvolatile writes, although the system still needs to handle power conditions and data integrity appropriately.

Endurance and retention for industrial data

Repeatedly updating the same nonvolatile memory locations can make endurance a key selection factor. The FM25C160B is specified for at least 1014 read/write cycles. Its architecture uses a read-and-restore mechanism, so endurance is counted on a row basis for memory-array access. The device has 256 rows of 64 bits; accessing a byte involves an internal access to its row.

This endurance specification can be relevant to control applications that write frequently, such as data collection or records updated during machine operation. It should not be treated as a guarantee of system lifetime on its own: engineers still need to consider the access pattern, operating conditions and the requirements of the complete application. The datasheet provides an example endurance calculation for a repeating 64-byte sequence, illustrating why workload and bus frequency matter when estimating use.

Nonvolatile retention is another part of the trade-off. The device specifies data retention of 151 years at 65 °C, 38 years at 75 °C and 10 years at 85 °C. These figures are temperature-dependent specifications, not a single retention value that applies under all conditions. For a real installation, the expected ambient temperature and required retention period should be compared with the applicable rating.

SPI integration and write protection

The FM25C160B supports SPI modes 0 and 3, with a clock frequency of up to 20 MHz. The interface uses chip select, serial clock, serial input and serial output. A microcontroller with a hardware SPI peripheral can communicate directly; a controller without one can emulate the interface using general-purpose pins. The serial input and output pins can also be connected together in a reduced-pin arrangement, as described in the device documentation.

Each memory read or write begins with an opcode followed by a two-byte address. The address identifies one of the 2,048 byte locations; the upper five bits of the transmitted address are ignored. During sequential access, the internal address advances as data is transferred, and wraps from the final address back to the start of the array. Writes require a Write Enable (WREN) command before the memory-write command. The write-enable latch is cleared after a write operation, so another write requires a new WREN.

Protection is layered through the status register and the active-low Write Protect (WP) pin. Software block-protection bits can protect the upper quarter, upper half or entire array. The WP pin can inhibit changes to the status register when the write-protect-enable bit is set; it does not directly protect the memory array. The distinction is important when designing a protection strategy. If WP or HOLD is unused, the datasheet says to tie the pin to VDD rather than leave it floating.

Design checks before selecting the device

Memory behavior is only one part of integration. The FM25C160B operates from 4.5 V to 5.5 V and is specified for an industrial ambient range of –40 °C to +85 °C. Its SPI clock can be interrupted, but the host must respect the device’s timing requirements and start a new opcode with a falling edge on chip select. After power-up, the device requires at least 1 ms from the supply reaching its minimum operating voltage before the first access.

The datasheet also places responsibility on the system designer to keep the supply within tolerance. The device has a simple internal power-on reset, not a broader power-management function; the guidance is not to power it down while chip select is active. In an industrial design, supply sequencing, chip-select behavior during reset and the handling of interrupted writes should therefore be considered alongside firmware and interface timing.

  • Confirm that the 4.5 V to 5.5 V supply range matches the controller’s memory interface.
  • Choose SPI mode 0 or 3 and verify clock, setup and hold timing against the intended host.
  • Plan write-enable handling and configure block protection for the data that must be guarded.
  • Check retention requirements at the expected operating temperature.
  • Account for power-up access timing and the possibility of power loss during a write; only the last completed byte is written if power is lost mid-operation.

Conclusion: match memory behavior to the workload

SPI F-RAM is most relevant when an industrial system needs nonvolatile storage that can tolerate frequent updates without serial flash or EEPROM write-cycle delays. The FM25C160B combines bus-speed writes, high specified endurance, temperature-dependent retention and a familiar SPI interface in a compact 2-Kbit-by-8 array. Engineers and system integrators should assess those benefits against capacity, voltage, temperature, protection and power-sequencing requirements. Matching the memory’s characteristics to the actual write pattern and operating environment is essential to making it a dependable part of a control-system design.