Access Official Technical PDF

Share Summary:LinkedInEmail

A spread spectrum differential clock can help address electromagnetic interference (EMI) considerations in systems that depend on stable, high-frequency timing. The CY25823 clock generator produces a 96 MHz or 100 MHz differential output and provides hardware and SMBus-compatible serial controls for selecting spread modulation and managing the clock outputs. For engineers integrating clock sources into control electronics, understanding its configuration options and operating requirements is essential to applying the device correctly.

How the CY25823 generates and modulates its clock

The CY25823 uses a phase-locked loop (PLL), including a voltage-controlled oscillator, dividers and a feedback path, to synthesize its output from a reference clock input. Its paired CLKOUT and CLKOUT# pins provide a differential clock with a nominal 0.7 V swing. The device supports 96 MHz and 100 MHz output frequencies, with frequency selection made through a power-up strap or the control register.

Spread spectrum clocking varies the clock frequency according to a selected modulation profile rather than holding it at a single fixed value. The CY25823 offers both down-spread and center-spread modes. Down-spread profiles modulate in one direction from the nominal frequency; center-spread profiles vary around the nominal frequency. The selectable spread amount ranges depend on the configuration and charge-pump setting.

This modulation is intended to reduce EMI. It does not remove the need to evaluate emissions in the complete design: system-level performance depends on the implementation and should be assessed against the applicable requirements.

Spread spectrum differential clock configuration options

At power-up, spread spectrum is enabled and hardware control is selected. The S[3:1] pins set the initial spread profile; in hardware mode, S0 is fixed at zero. The REFOUT/SEL pin is also sampled during power-up to choose 96 MHz or 100 MHz: a pull-up selects 100 MHz, while a pull-down selects 96 MHz. After startup, that pin provides a 14.31818 MHz reference output.

For designs that need software configuration, the serial interface can change spread settings and output frequency. The control register includes a hardware/software selection bit and spread-spectrum enable control. In software mode, all four spread-select bits can be programmed. The interface also provides output-enable and charge-pump controls.

The spread profile tables offer multiple settings rather than a single fixed modulation depth. With the default charge-pump setting, down-spread selections range from 0.65% to 2.25%, while center-spread selections range from ±0.25% to ±1.10%. Other charge-pump settings provide different spread amounts. The selected option should be evaluated in the context of the system’s frequency and EMI requirements.

Serial control and output management

The two-wire serial interface supports byte and block read and write operations. Register values initialize to their defaults at power-up, so software configuration is optional; changes may be made during system initialization or used for power management during operation. Reserved register bits must be kept at their specified values, and block operations access bytes in sequence.

The CLKOUT enable bit can place the differential outputs in a three-state condition while leaving the PLL and oscillator running. The transition into and out of this state is described as glitch-free. This is distinct from the PWRDWN input, which shuts down the synthesizer and oscillator as well as tri-stating the clocks.

Power sequencing and electrical design considerations

PWRDWN is an asynchronous, active-high input that is synchronized internally for shutdown. Before asserting it, CLKIN must be present and within its operating parameters; it must remain in that state while power-down is asserted. During restart, allow the VCO to stabilize before relying on the outputs. The specified clock stabilization time from power-up is 3.0 ms, and the shutdown supply current is specified at up to 250 µA under the stated no-input-clock condition.

The device operates from a 3.3 V supply, with the logic/output and PLL supplies specified at 3.3 V ±5%. The application schematic ties VDD and VDDA together, and connects VSSIREF and VSS to a common ground. A separate analog ground pin is provided for the PLL; follow the reference schematic and board-level design requirements when planning grounding and decoupling.

An external resistor at IREF sets the differential driver current. The recommended 475 Ω value corresponds to a reference current of approximately 2.32 mA; the output current is scaled to six times IREF. The reference design also shows series resistors on the clock outputs and termination components. These details are part of the specified implementation, not interchangeable performance guarantees for every board layout.

Interpreting clock specifications

For both output frequencies, the specified duty-cycle range is 45% to 55%, and cycle-to-cycle jitter with spread spectrum enabled is up to 200 ps under the stated measurement conditions. The 100 MHz output period is specified as 9.990 to 10.010 ns; the 96 MHz period is 10.406 to 10.427 ns. Output rise and fall times are specified from 175 ps to 700 ps. These values should be considered alongside the stated measurement points, load configuration and operating conditions when checking compatibility with downstream timing inputs.

Practical implications for system designers

The CY25823 combines frequency selection, selectable spread modulation, differential outputs and serial configuration in a 16-pin TSSOP device. Successful integration depends on more than choosing 96 MHz or 100 MHz: designers must also select an appropriate spread profile, establish the required strap states, observe startup and shutdown sequencing, and implement the reference-current and output-network components correctly.

For system integrators and hardware teams, the practical approach is to treat clock configuration and board implementation as a complete design task. Confirm the downstream clock requirements, choose hardware straps or software control deliberately, and validate the assembled system against its timing and EMI criteria. The data sheet’s electrical limits and application schematic provide the basis for that evaluation.

Access Official Technical PDF

About The Author