Access Official Technical PDF

Share Summary:LinkedInEmail

Choosing and integrating a stepper motor driver involves more than matching a motor’s current rating to an IC’s headline specification. The TB67S279FTG, TB67S289FTG and TB67S249FTG are CLK-input drivers for a single two-phase bipolar stepping motor, with configurable microstepping, constant-current control and optional Active Gain Control (AGC). For engineers and system integrators, successful implementation depends on setting current appropriately, managing heat, designing clean control signals and validating protection behavior in the intended application.

Stepper motor driver capabilities and operating limits

The three devices use the same pin assignments and QFN48 package, but differ in output capability, current-setting gain and overcurrent-detection threshold. Their stated absolute maximum output-current ratings are 2 A for the TB67S279FTG, 3 A for the TB67S289FTG and 4.5 A for the TB67S249FTG. These are absolute limits, not guaranteed continuous operating currents: the usable current depends on ambient temperature, PCB layout, heat dissipation and the motor’s excitation conditions.

The motor supply, VM, has an operating range of 10 V to 47 V and a 50 V absolute maximum rating. The IC includes an internal regulator for its logic supply, so a separate external logic supply is not required for normal operation. VREF, which sets the PWM current threshold, operates from 0 V to 3.6 V, with a 5 V absolute maximum rating. The application note also gives lower recommended current ranges for appropriate operation: 0.5–1.0 A for the TB67S279FTG, 1.0–1.5 A for the TB67S289FTG and 1.5–2.0 A for the TB67S249FTG. Confirm suitability against the motor and actual board conditions.

Set motor current through VREF

These drivers use the Advanced Current Detection System (ACDS) for constant-current PWM control, eliminating the need for an external current-detection resistor. The approximate output-current setting is determined by VREF and the gain associated with the selected device:

  • TB67S279FTG: Iout = VREF × 0.556
  • TB67S289FTG: Iout = VREF × 0.833
  • TB67S249FTG: Iout = VREF × 1.250

For example, a 2 V VREF input corresponds to approximately 1.67 A on the TB67S289FTG. This is a typical-value calculation, so it should not replace checking the relevant device data and validating the current in the finished design. If VREF is derived from the internal VCC regulator using a resistor divider, the application note specifies a combined divider resistance of 10 kΩ to 100 kΩ and cautions that the regulator must be able to support the resulting load.

Choose microstepping and control signals deliberately

An internal CLK-in decoder advances the motor’s electrical angle on each rising edge of CLK. Available settings are full step, half step (a or b), quarter step, and 1/8, 1/16 or 1/32 step. The CLK input includes a 200 ns analog filter to help reject noise, but noise that persists through the filtering period can still produce an unintended step. Route and protect the clock signal accordingly, and consider the filter when selecting the maximum input frequency.

ENABLE controls the output stage: high enables motor operation, while low turns off the output MOSFETs and places the outputs in a high-impedance state. CW/CCW selects direction. RESET initializes the internal electrical angle, and the MO open-drain output can indicate when that angle is at its initial position if it is pulled up appropriately. The DMODE pins select step resolution; setting all three low selects standby. After releasing standby, allow the internal circuit to stabilize before sending drive signals. The application note indicates approximately 1 ms.

Configure AGC for the load profile

AGC is an optional anti-stall and current-management feature. When enabled, the driver can reduce motor current when the required torque is below the VREF-defined upper current limit, then increase current as load demand rises. This can help avoid applying the full configured current continuously, but the settings must be evaluated with the motor and mechanical load.

Several pins shape AGC behavior. CLIM sets a lower current limit in eight levels, from 45% to 80% of the VREF-set current. The application note suggests beginning evaluation at 80% and reducing the limit while checking that the system continues to operate reliably. BOOST selects how quickly current recovers as torque demand increases: its four configurations range from a maximum of five steps to reach 100% current to a maximum of eleven steps. Faster recovery may be more appropriate for rapidly changing torque demands; slower settings may suit slower changes.

FLIM sets a lower CLK-frequency threshold below which AGC is inactive, helping address operation at very low motor speeds. Its thresholds depend on step resolution, and grounding the pin disables the frequency limit. LTH configures detection sensitivity; the normal configuration uses a 100 kΩ resistor, while a lower value increases sensitivity and may make current unstable with some motors. These controls should be treated as coordinated tuning parameters, not assumed to work identically across motors.

Balance chopping frequency, thermal design and protection

The chopping frequency is one of the trade-offs in driver setup. Higher frequency reduces motor-current ripple and can improve waveform quality, but increases switching loss and heat. The application note recommends a typical value near 67 kHz and gives a general evaluation range of 50 kHz to 120 kHz. Frequency can be set with an external resistor and capacitor at OSCM; with a 270 pF capacitor, the resistor is adjusted to change the internal oscillator frequency, of which the chopping frequency is one-sixteenth. Alternatively, the OSCM pin can be connected to ground to select the component-elimination mode, which uses a typical chopping frequency of about 60 kHz. Do not change OSCM mode while the motor is operating.

Thermal performance depends on both output-stage losses and internal circuit consumption. The device’s junction temperature is affected by power dissipation, ambient temperature and the board’s thermal resistance. The QFN package transfers heat through its underside thermal area, so the PCB layout should provide an appropriate heat path to ground. Keep power and ground routing suitable for motor current, place supply capacitors close to the IC, and evaluate temperature in the actual operating environment. A fuse on the supply line is also recommended: built-in overcurrent protection is not a substitute for system-level protection under every fault or wiring condition.

Design for controlled startup and fault handling

Although the internal regulator supports single-supply operation, control inputs should be held low while VM is absent and during power-up and shutdown. Apply operating signals after VM and VREF are within their operating ranges. Under-voltage lockout and power-on reset initialize internal logic below their detection thresholds, but correct sequencing remains important for predictable system behavior.

Thermal shutdown, overcurrent protection and motor-load-open detection are available, with open-drain error outputs LO1 and LO2 indicating specified fault states when pulled up. The application note describes recovery from thermal and overcurrent shutdown through cycling VM or entering standby. Confirm fault reporting and recovery behavior in the full design, and address the cause of a fault rather than relying on protection circuits as routine operating controls.

Conclusion

The TB67S279FTG, TB67S289FTG and TB67S249FTG combine microstepping, VREF-based constant-current control and optional AGC in a CLK-input stepper motor driver. Their practical performance depends on selecting a device and current setting for the motor, tuning AGC and chopping frequency to the load, and designing the PCB for signal integrity and heat removal. The cited application note is marked preliminary and dated 2018; verify current manufacturer documentation and validate the complete design before production.

Access Official Technical PDF

About The Author