Thermoelectric generators could offer South African operators another way to produce electricity from heat that is currently unused or discharged. These solid-state devices convert a temperature difference directly into electrical voltage, making them a potential fit for some geothermal resources and industrial waste-heat streams. Their relevance is not that they replace established generation technologies in every application, but that they may make smaller, distributed heat-recovery projects worth evaluating.

For engineers and energy planners, the key questions are practical: Is there a sustained heat source? Can a useful temperature difference be maintained across a thermoelectric module? And can the resulting power justify installation and integration costs? South Africa’s geological indicators and industrial heat losses provide reasons to investigate those questions, while the available evidence also makes clear that more site-specific data is needed.

Why consider thermoelectric generators?

A thermoelectric generator (TEG) uses the Seebeck effect. When dissimilar semiconductor materials experience a temperature difference, they produce a voltage. A module therefore needs both a hot side, connected thermally to a heat source, and a cooler side that allows heat to flow through the device. The resulting electrical output depends on the temperature difference and the module and system design.

Unlike Steam Rankine Cycle or Organic Rankine Cycle systems, a TEG does not use heat to drive a turbine through a mechanical cycle. Its solid-state construction has no moving parts, which can simplify equipment arrangements for certain applications. The trade-off is that conversion efficiency and power output depend on the temperature conditions and installed system. A heat source alone is not enough: designers must also provide an effective heat-transfer path and a heat sink.

This makes TEGs a technology to assess alongside, rather than automatically ahead of, other heat-recovery options. Conventional cycles may suit larger or hotter heat sources, while TEGs may be considered where direct conversion and modular deployment are useful. The appropriate choice depends on the heat source, operating conditions, power requirement and project economics.

South Africa’s geothermal opportunity

South Africa has no large-scale geothermal electricity production, but the geological indicators discussed in the research point to areas that warrant further investigation. Heat-flow measurements identify above-average values in parts of Namaqualand and around the south and west of Upington, as well as in Lesotho. The research also identifies the northern part of KwaZulu-Natal and areas associated with the Limpopo and Namaqua-Natal geological belts as locations of interest.

Reported resource estimates include temperatures of roughly 100–150°C at depths of 3,000–5,000 metres in some hot dry rock areas. Deep fractured aquifers in the Limpopo and Cape Fold belts are described as having temperatures of about 60–80°C at depths of 1,000–2,000 metres. Surface hot springs provide another indication of subsurface heat: the Tshipise–Sagole–Siloam group in Limpopo is reported at 45–60°C, while Brandvlei in the Western Cape is reported at 64°C. These surface temperatures are indicators, not a substitute for measurements from a drilled production site.

For a project developer, the implication is that regional maps can guide exploration but cannot establish a plant’s output or viability. Temperature at depth, heat-flow characteristics, fluid availability, drilling requirements and the intended electrical load all need to be evaluated for the specific site.

Recovering industrial and transport waste heat

Geothermal resources are only one possible heat source. Industrial processes, vehicles and buildings also release heat that may be recoverable. The source paper estimates that a substantial share of primary energy is lost as waste heat, though the amount available to a TEG at any particular facility will depend on its processes and operating profile. Potential sources include heated water, exhaust streams and other steady thermal discharges.

Before specifying a system, plant teams should characterize the heat source over time rather than relying on a single temperature reading. Useful assessment questions include:

  • What are the source temperature and flow conditions during normal operation?
  • How continuously is the heat available, and how does it vary with production?
  • Can heat be transferred to the TEG while maintaining a cooler temperature on its opposite side?
  • Where can the electrical output be used or connected?
  • What installation, maintenance and integration costs apply at the proposed scale?

Vehicle exhaust is another proposed application because fuel energy leaves the engine in part as heat. The research cites estimates of substantial exhaust heat losses and describes automotive TEG development as an area of interest. For industrial decision-makers, this illustrates the principle rather than guaranteeing a particular recovery rate: actual output requires measurement and engineering assessment of the specific system.

Assessing scale, cost and readiness

One potential advantage of TEGs is the possibility of generating power at smaller scales, including at heat sources that are dispersed or remote. The research argues that modular systems could avoid some of the large infrastructure associated with turbine-based approaches. This could make localized generation worth assessing where a reliable heat source is available and a modest electrical load can use the output.

However, the paper’s economic appraisal does not establish a definitive TEG cost for South African projects. It reports a levelized cost of electricity of 14 US cents per kilowatt-hour for a hypothetical 75 MW geothermal development in the Soutpansberg using a binary system; a modelled feed-in tariff reduces that figure to 12 cents. The authors suggest a TEG system could cost less because it may require less mechanical equipment and infrastructure, but this is a projection, not a directly demonstrated cost comparison. Site investigation, equipment costs and system performance would be needed to test the case.

Resource characterization is also an important next step. The paper notes that available geological information is limited and calls for further heat-flow investigation and more accurate geological and engineering data. That evidence is essential to determine whether a proposed project can deliver steady heat and useful electrical output over its operating life.

Practical implications for project teams

Thermoelectric generation may be worth screening where a facility has a consistent heat source that would otherwise be rejected, or where geothermal exploration identifies a suitable low- or medium-temperature resource. Its solid-state design can be attractive for compact or distributed applications, but it does not remove the need for thermal design, resource assessment or a credible economic model.

For South African developers and plant operators, the most useful next step is a measured feasibility assessment: quantify the available heat, establish the temperature difference a system can maintain, estimate the electrical load it could serve, and compare lifecycle costs with other recovery options. The country’s geothermal prospects and waste-heat streams offer reasons to investigate thermoelectric generators, but project decisions should rest on validated site data rather than regional potential alone.