Trans-1,2-dichloroethylene semiconductor use is narrowly tied to specific high-temperature processes in wafer fabrication. In comments submitted to the U.S. Environmental Protection Agency (EPA), the Semiconductor Industry Association (SIA) describes the chemical as a liquid source used to generate hydrogen chloride or chlorine in oxidation and furnace tube cleaning. The submission also details how fabs deliver the chemical and manage potential exposure. These process conditions matter when evaluating chemical use in a highly controlled manufacturing environment.
Where the chemical fits in wafer fabrication
Semiconductor manufacturing builds integrated circuits through repeated cycles of adding material to a wafer, patterning it, and selectively removing material. Photolithography defines patterns in a photoresist coating; deposition adds thin films; etching removes selected areas; and doping changes silicon’s electrical properties. Cleaning steps are interspersed throughout because contaminants can affect device quality.
Some fab processes take place in diffusion furnaces. During oxidation, a high-temperature step forms a silicon dioxide layer on the wafer. The SIA submission says trans-1,2-dichloroethylene is used in these furnaces as a source of chlorine-containing chemistry and water, and to help sequester metal contaminants. It is also used to clean furnace tubes. The submission identifies diffusion, another high-temperature batch process, as an additional point of use.
These operations are part of a much larger production flow. Wafers move between specialized tools for many process iterations, while controls over temperature, chemistry, contamination, and handling support repeatable fabrication. The chemical’s described role is specific to furnace operations rather than a general-purpose material used throughout the fab.
How trans-1,2-dichloroethylene is delivered and consumed
According to the SIA comments, the chemical is supplied as a liquid in sealed containers. A nitrogen push gas transfers it from a bulk container to a smaller source container installed at the process tool. Nitrogen carrier gas then passes through the liquid to deliver it to the furnace.
In the described oxidation process, the furnace operates at atmospheric pressure and temperatures in the range of 700 to 1,200 degrees Celsius. The submission states that trans-1,2-dichloroethylene is transformed in the process into hydrogen chloride and other inorganic chlorides. It argues that the compound is not present in the finished wafer, and that residual material could compromise oxide quality. These statements concern the specific controlled process described in the submission.
The SIA identifies trans-1,2-dichloroethylene as a replacement for 1,1,1-trichloroethane (TCA), which was previously used as a chlorine source. The comments cite concern about TCA’s ozone depletion potential as a reason for the transition. They also state that direct hydrogen chloride is not considered an acceptable substitute by the industry, citing process performance and concerns about handling the gas in the fab environment.
Fab controls and equipment design
Semiconductor facilities combine process equipment, chemical delivery infrastructure, ventilation, and operating procedures. Manufacturing tools are located in cleanrooms, while supporting services—including chemical supply and air-handling equipment—may be located in ancillary areas such as a sub-fab. The SIA submission describes automated wafer handling, enclosed containers, and extensive air circulation as features of fab operations, primarily intended to protect product quality and maintain controlled conditions.
For trans-1,2-dichloroethylene, the submission describes several layers of process and facility control:
- Closed chemical delivery: Sealed source and bulk containers connect to enclosed supply and discharge systems, avoiding routine manual pouring.
- Tool safeguards: Exhaust and interlocks are used to reduce the potential for chemical release during processing.
- Ventilation: Local exhaust ventilation is used around relevant operations, with continuous monitoring and alarms described for the process environment.
- Effluent treatment: The submission says residual hydrogen chloride and chlorine in process exhaust are routed to an acid exhaust system and treated using a wet scrubber.
- Container management: Empty containers are returned to the manufacturer for reprocessing and refilling.
The chemical containers described in the comments use specialized valves and a sealed connection intended to limit exposure during installation and removal. This is an example of how equipment interfaces can be part of chemical risk management, alongside ventilation and process controls.
Worker exposure controls during operation and maintenance
Routine production and maintenance present different control needs. During normal operation, automated delivery and enclosed tools limit direct handling. Maintenance, by contrast, can require opening equipment after it has been taken out of service. The SIA comments describe purging tools before invasive maintenance, conducting work at room temperature under local exhaust ventilation, and using personal protective equipment as required.
Other measures listed include industrial hygiene review, chemical safety training, segregated storage, and protective clothing and equipment during container changes. The submission also notes that older equipment may have less sophisticated protective features, making engineering controls, administrative procedures, and PPE important parts of exposure management.
These measures reflect a layered approach: prevent releases through system design, capture or treat emissions through ventilation and abatement, and apply work practices and PPE when equipment must be accessed. The comments characterize the use as highly controlled; they do not replace a site-specific assessment of equipment, procedures, or exposure conditions.
Practical implications for fab operations
For plant managers, process engineers, and EHS teams, the account highlights why chemical evaluations should consider the complete use scenario—not only a substance’s identity. The process step, delivery configuration, operating conditions, exhaust treatment, container handling, and maintenance practices all shape how the chemical is managed.
In its EPA submission, the SIA asks that the semiconductor industry’s specialized uses and controls be accurately characterized as risk evaluation proceeds. The practical takeaway is that fab chemical management depends on integrated process and facility controls, with particular attention to closed delivery, exhaust systems, and maintenance access. Documenting those conditions helps technical and safety teams describe how a chemical is used within the manufacturing process.