Wearable motion sensors can turn human movement into data that engineers and researchers can review, compare, and store. Moveo Explorer is a system built around ERT Opal V2R sensors, which use triaxial accelerometers, gyroscopes, and magnetometers to record movement. Its software supports sensor configuration, test execution, visualization, and reporting of kinematic data, including joint angles, gait measures, balance metrics, and raw sensor data.

For technical teams evaluating a movement-measurement workflow, the system illustrates how body-worn sensing can connect data capture with structured analysis. It is intended for research and engineering applications where quantifiable physical motion is useful; it is not a medical device.

How Moveo Explorer wearable motion sensors work

Opal sensors are attached to selected body locations using adjustable straps. A test participant performs a defined task, and the sensors record movement for analysis in Moveo Explorer. The available measures depend on the selected test and sensor configuration. The system can display results in graphs and tables, and users can export trial data.

The hardware includes the Opal sensors, a Docking Station for charging, configuring, and transferring logged data, and an Access Point for wireless communication with the computer. The software supports both streaming and logging modes when logging is enabled. The supplied system can include up to 15 Opals, while one Access Point supports up to six Opals at a 128 Hz sampling rate.

This arrangement separates several tasks that are often treated as one: placing sensors consistently, acquiring movement data, and interpreting the results. Careful configuration at the start helps make the resulting data meaningful.

From sensor placement to a completed test

Configure the hardware and body locations

Before a session, connect the Access Point to the Docking Station, connect the Docking Station to its power supply and computer, and dock the Opals. In the software, assign each sensor to a body location by matching it to the on-screen model. Custom sensor locations can also be entered. The Opal identifier can help confirm that a sensor with a specific strap is assigned correctly.

Placement depends on the measurement objective. The system supports locations that include the foot, lower and upper leg, lumbar region, sternum, head, upper arm, wrist, and hand. The instructions specify positioning for each site; for example, the foot sensor is centered on top of the foot, while the lumbar sensor is centered on the lower back at the base of the spine. Opals should be placed port-side down.

Select tests and guide the participant

Moveo Explorer includes defined tests such as walking, timed up-and-go, sway, sit-to-stand, and turning, as well as free-form movement. Users select a test and its condition or choose a predefined sequence, then follow the instructions shown in the software. The system supports subject groups, individual subject records, and configurable test sequences, which can help organize repeated data collection.

During the three-second countdown at the start of a test, the participant should remain still for calibration. If a wireless remote is being used, its forward button can start and stop each test. Clothing should not significantly restrict movement; for walking tests, walking shoes are recommended, with barefoot walking preferable to heels or flip-flops if suitable shoes are unavailable.

Interpreting movement metrics and reports

Moveo Explorer presents measures according to the selected test and sensor setup. For walking, available lower-limb measures include cadence, gait speed, step duration, stride length, stance and swing phases, foot strike angle, and toe-out angle. Other test results can include turn angle, duration, and velocity; sit-to-stand duration and trunk lean angle; or postural sway measures.

These metrics describe different aspects of movement rather than a single overall result. For example, gait speed represents forward distance traveled during a gait cycle divided by the cycle duration, while cadence counts steps per minute. Reviewing definitions and visualizations together can help users understand what a measure represents. The results window provides metric definitions, graph views, filters, and table options such as metric values, percentiles, and Z-scores. Users can also edit displayed metrics, print a view, and export trial data.

Operational considerations for reliable data collection

Sensor preparation and session conditions affect whether a test can be completed and its data retained. Keep the Access Point connected during testing; unplugging it may result in lost data. For test sessions using a laptop, keep the computer connected to power, since a low battery may also cause test data loss. Back up the Moveo Explorer database before upgrading or uninstalling the software.

Data handling deserves particular attention. The database may contain personal or protected health information, but Moveo Explorer does not secure or encrypt the database itself. Access should therefore be protected using the computer operating system’s security controls. Recommended practices include separate user and administrator accounts, strong passwords, locking the computer when unattended, regular secure backups, and disk-level encryption.

After each use, clean Opals with a low-level disinfectant applied to a soft, lint-free cloth. Do not immerse or spray the sensors. Straps can be removed and washed separately with mild soap and water. The sensors are water resistant, not waterproof, and should not be submerged. Follow the supplied operating and safety instructions, including the guidance on environmental limits and approved accessories.

Conclusion

Moveo Explorer combines wearable motion sensors with a configurable test workflow and software for analyzing and exporting movement data. For engineering and research teams, its practical value depends on matching sensor placement and test selection to the measurement objective, following calibration and operating procedures, and managing the resulting data securely. Understanding those steps helps teams assess whether this approach to kinematic data collection fits their application.