Access Official Technical PDF

Share Summary:LinkedInEmail

48V automotive power systems are attracting attention as electrification, advanced driver-assistance systems (ADAS) and increasingly capable infotainment raise the electrical demands of modern vehicles. The long-standing 12V bus still supports many established vehicle electronics, but delivering more power through it means higher current and greater demands on wiring and connections. A complementary 48V network can help address those constraints while preserving 12V compatibility.

Why vehicle power requirements are changing

Earlier generations of vehicles had comparatively modest electrical loads. Today, vehicles may include more sensors, cameras, displays, processors and electrically driven components. ADAS and automated-driving functions add distributed computing and sensing, while infotainment systems combine navigation, communications, audio, video and user interfaces. Electrified versions of pumps, compressors and climate-control equipment also add loads that were once served mechanically.

The result is not simply a need for more battery capacity. Designers must distribute power to components located throughout the vehicle, with attention to wiring, conversion stages and the requirements of each load. CPUs and GPUs, for example, can require low input voltages even when supplied from a higher-voltage vehicle bus. Converting power efficiently and close to the load therefore becomes an important part of the architecture.

Where 48V fits in a vehicle power architecture

Vehicle electrification spans several configurations. A battery electric vehicle relies on its battery and electric motor for propulsion. Full and plug-in hybrids can support electric driving, while mild hybrids generally use a smaller energy store and do not provide an all-electric driving mode. Micro-hybrid systems may retain a 12V bus for their electrical functions.

These distinctions matter because the appropriate voltage depends on the power and functions required. In a mild hybrid, a 48V bus can serve higher-power loads while a 12V network continues to support electronics designed around the established standard. The two buses can coexist rather than requiring an immediate, wholesale replacement of 12V components.

How higher bus voltage reduces distribution current

For a given power level, increasing voltage reduces the current required to deliver that power. This is the central distribution advantage of moving some loads from 12V to 48V. Lower current can ease the demands on conductors and connectors, and may allow designers to reduce wiring mass while maintaining suitable distribution losses.

Consider a 120W load: at 12V it draws 10A, while at 48V it draws 2.5A. In the whitepaper’s illustrative design example, a bus carrying 10A can provide 120W at 12V or 480W at 48V. The actual wiring design depends on system requirements, but the example shows why higher voltage is useful as vehicle power demand grows.

A 48V bus does not, by itself, solve the conversion needs of every component. Many existing devices still require 12V, and processors may operate at much lower voltages. The power architecture must therefore coordinate bus conversion with the input requirements of each subsystem.

Direct conversion and point-of-load design

One way to reduce conversion stages is to use a point-of-load (PoL) converter that regulates power for a specific device near that device. For a processor with an approximately 1V input, a conventional path might step 48V down to 12V and then use another buck converter to reach the processor’s operating voltage. A suitable single-stage PoL approach can instead convert from the higher-voltage source to the required load voltage, avoiding an intermediate conversion stage.

Designing for a large difference between input and output voltages brings challenges. Efficiency optimization, ripple rejection and noise suppression all require attention. The conversion approach also needs to match the load: the whitepaper describes ZVS buck and buck-boost converters for lower-power loads, and a factorized architecture using PRM buck-boost regulators and VTM current multipliers for higher-current applications. These are examples of design approaches, not a universal solution for every vehicle load.

Infotainment illustrates the scale of the challenge

An infotainment system can combine a head-unit CPU and GPU, premium audio, digital signal processing, multiple displays and wireless connectivity. The whitepaper’s estimates for the listed components total approximately 1kW, with the head unit and audio system making up substantial portions. It notes that actual component mixes and power requirements vary by vehicle model.

At approximately 1kW, the example equates to roughly 84A on a 12V supply. If the same total load were distributed at 48V, the current would be about 21A, assuming the stated design factors. This comparison illustrates the potential benefit of higher-voltage distribution; it does not mean every infotainment device should connect directly to 48V. Individual loads still need appropriate conversion and regulation.

Keep traction power and auxiliary distribution distinct

Traction systems in full hybrids and plug-in electric vehicles introduce additional power-conversion requirements. Battery voltage can vary during charge and discharge, with further transients associated with powertrain loading. Converters serving traction-related functions must accommodate the relevant voltage range and may need input-output isolation. Those requirements can affect efficiency and power density.

By contrast, the whitepaper describes non-isolated 48V and 12V distribution as an option for certain mild-hybrid auxiliary loads, such as controls, infotainment and cabin lighting. A mixed-voltage architecture can retain compatibility with 12V electronics while using 48V where it helps with power distribution. Converter efficiency, packaging, isolation requirements and the needs of connected loads all influence the final design.

Practical implications for vehicle designers

For automotive engineers and system integrators, the shift toward 48V is an architectural decision, not just a battery-voltage change. Assess the power profile and location of major loads, identify which subsystems can use 48V, and determine where 12V compatibility remains necessary. Then evaluate conversion stages, voltage variation, noise, isolation and wiring requirements across the complete system.

As vehicle electronics and electrified functions expand, 12V alone can become a difficult foundation for distributing higher power. A complementary 48V network can lower current for a given load and create more flexibility for power-hungry systems. The practical benefit depends on matching the bus, converters and load requirements—while treating traction power and auxiliary distribution as distinct design challenges.

Access Official Technical PDF

About The Author