A ketoprofen fluorescence sensor developed from carbon dots and a molecularly imprinted polymer illustrates how selective chemical recognition can be paired with an optical readout. The material was designed to detect ketoprofen by measuring a reduction in fluorescence when the drug binds to recognition sites in a polymer shell. Its reported response was tested in human serum and urine, offering an example of a fluorescence-based analytical method for complex biological samples.

The design addresses a basic challenge in fluorescence analysis: ketoprofen itself is weakly fluorescent, so detecting it directly by fluorescence can be difficult. Instead, the sensor uses fluorescent carbon dots to generate the signal and a molecularly imprinted layer to help distinguish the target compound.

How the ketoprofen fluorescence sensor is structured

The sensing material has a core-shell architecture. The core consists of fluorescent carbon dots, while the surrounding shell is a silica-based molecularly imprinted polymer. The dots provide fluorescence; the polymer is intended to provide selective binding.

Molecular imprinting creates cavities in a polymer using a target molecule, known as the template, during material synthesis. After the template is removed, the resulting cavities retain features complementary to it, including aspects of its size, shape and chemical functionality. When the target returns, it can bind in these sites. In this material, ketoprofen was used as the template.

The researchers used a hydrothermal method to prepare silane-functionalized carbon dots from citric acid and an amino-functional silane reagent. They then formed the polymer shell through sol-gel polymerization, using silica precursors in the presence of ketoprofen. Washing removed the template and left recognition cavities in the shell. A non-imprinted polymer, prepared without ketoprofen, served as a comparison material.

Why use a surface-imprinted core-shell design?

In conventional bulk molecularly imprinted polymers, binding sites can be distributed unevenly or located deep within the polymer. This can make template removal and subsequent target binding less straightforward. A core-shell approach places recognition sites at or near the surface, where the target can access them more readily.

Here, the sol-gel process formed a silica-based shell around the fluorescent core. The carbon-dot fluorescence remained observable after coating, with the material showing an emission maximum at 450 nm when excited at 360 nm. This matters because the shell needs to support molecular recognition without preventing the optical signal from being measured.

The non-imprinted control is important to interpreting selectivity. Both materials can respond to compounds in their surroundings, but a stronger response from the imprinted material indicates that the target-shaped binding sites contribute to recognition. The reported imprinting factor was 2.35, reflecting the greater response of the imprinted material compared with the non-imprinted control under the study’s conditions.

Fluorescence quenching provides the readout

When ketoprofen binds to the imprinted sites, the fluorescence intensity of the carbon-dot material decreases, a process called fluorescence quenching. The authors attributed this response to interactions between amino groups in the binding sites and functional groups, including carbonyl groups, on ketoprofen. The interaction changes the fluorescence signal, allowing the target concentration to be estimated from the degree of quenching.

The response depended on ketoprofen concentration. Under optimized conditions, the sensor produced a linear response from 0.039 to 3.9 μM, with a reported correlation coefficient of 0.999. The reported detection limit was 0.01 μM, calculated using a signal-to-noise ratio of 3. These figures describe performance under the study’s specified analytical conditions; they should not be assumed to apply unchanged to other sample types or measurement setups.

Several operating conditions were assessed. The greatest fluorescence change was observed at pH 6, and the signal stabilized within five minutes after ketoprofen was added. These findings establish the conditions used for the reported measurements, rather than a general specification for every possible application of the material.

Selectivity and testing in biological samples

The sensor was evaluated against potential interferents, including common ions and compounds such as glucose, uric acid and ascorbic acid. The study defined tolerance by whether an added substance caused a fluorescence-signal variation beyond ±5%. It also examined structurally related anti-inflammatory drugs: ibuprofen, fenoprofen and naproxen. These compounds caused some quenching, but ketoprofen produced the strongest response, consistent with preferential recognition by the imprinted sites.

To assess use in biological fluids, human serum and urine samples were spiked with known amounts of ketoprofen. The samples were treated with zinc sulfate and barium hydroxide to precipitate proteins, centrifuged, diluted and then analyzed using the fluorescence procedure. Reported recoveries ranged from 96% to 104% for the tested samples. These results support the method’s application to the prepared serum and urine samples; they do not, by themselves, establish performance for every clinical or industrial matrix.

Practical implications for analytical method development

The work demonstrates a useful materials-design principle: pair an optical reporter with a recognition layer designed for a particular analyte. Carbon dots provide the measurable fluorescence, while surface imprinting supplies binding sites intended to improve target selectivity. Comparing the imprinted material with a non-imprinted control helps show how much the recognition layer contributes to the response.

For engineers and technical decision-makers assessing sensing approaches, the practical lesson is to evaluate the complete measurement system rather than a headline detection limit alone. Relevant considerations include sample preparation, pH, response time, interfering compounds and whether performance has been demonstrated in the intended sample matrix. In this study, the reported evidence is specific to ketoprofen measurement in prepared serum and urine samples.

Conclusion

This carbon-dot, molecularly imprinted core-shell material detects ketoprofen through concentration-dependent fluorescence quenching. Its surface-oriented recognition sites, response within five minutes under the reported conditions, and recovery results in spiked serum and urine demonstrate the potential of combining molecular imprinting with fluorescent nanoparticles for selective analysis. Further evaluation would be needed before applying the method to other matrices or measurement contexts.