A high-voltage switching diode must be assessed against more than its headline voltage rating. Forward current, surge limits, reverse leakage, recovery time, capacitance and thermal conditions all affect whether a component fits a circuit. The 1SS82 is a silicon epitaxial planar diode specified for switching, with a 200 V reverse-voltage rating and a 250 V peak reverse-voltage rating. Its datasheet provides a useful example of how to interpret these limits during component selection and design review.

What the 1SS82 diode is specified to do

The 1SS82 is supplied in a DO-35 package and uses a glass seal, which the datasheet identifies as a reliability feature. The axial package has a cathode band for polarity identification: the cathode is at the banded end, and the opposite lead is the anode. The specified color bands are verdure for the cathode band and light blue for the second band.

In a switching circuit, a diode conducts in the forward direction and blocks current in the reverse direction. The 1SS82’s ratings define the conditions within which those functions are specified; they are not interchangeable operating targets. In particular, the peak reverse-voltage limit is not a substitute for the rated reverse voltage.

Key electrical and absolute-maximum ratings

The datasheet gives absolute maximum ratings at an ambient temperature (Ta) of 25°C. These limits should be treated as boundaries, not as recommended continuous operating points.

  • Reverse voltage (VR): 200 V.
  • Peak reverse voltage (VRM): 250 V. The datasheet cautions that exceeding this peak may deteriorate electrical characteristics.
  • Average forward current (IO): 200 mA.
  • Peak forward current (IFM): 625 mA.
  • Non-repetitive peak forward surge current (IFSM): 1 A, within a one-second surge condition.
  • Power dissipation (Pd): 400 mW.
  • Junction temperature (Tj): 175°C; the storage-temperature range is −65°C to +175°C.

These figures describe different constraints. For example, the one-second, non-repetitive surge rating does not establish that the diode can carry 1 A repeatedly or continuously. Likewise, average current and power dissipation must be considered alongside the circuit’s thermal conditions and installation. The datasheet’s limits apply under the stated conditions; the design must remain within the guaranteed ranges.

Forward drop, leakage and switching behavior

At a forward current of 100 mA, the specified maximum forward voltage (VF) is 1.0 V. This gives designers a reference point for evaluating the voltage across the conducting diode under that test condition. The datasheet also plots forward current against forward voltage at several temperatures, illustrating that the relationship varies with temperature. The plotted curves are useful context, but they do not replace the stated test condition or maximum rating.

Reverse leakage is specified at two reverse-voltage conditions. The maximum IR1 value is 0.2 µA at VR = 200 V. The datasheet also lists an IR2 value of 100 at VR = 250 V; when using this figure, consult the applicable complete product specification to confirm the table’s unit and conditions. Leakage matters when a circuit must maintain a reverse-blocking state, particularly when evaluating operation near the device’s voltage limits.

The 1SS82 has a maximum reverse recovery time (trr) of 100 ns under the stated test setup: IF and IR are each 30 mA, Irr is 3 mA, and the load resistance is 100 Ω. Recovery time describes the transition after the diode changes from forward conduction toward reverse blocking. Because the value is tied to specific test conditions, it should not be treated as a universal switching time in every circuit.

The specified capacitance is typically 1.5 pF, measured at zero reverse voltage and a frequency of 1 MHz. The datasheet also provides a capacitance-versus-reverse-voltage curve. For designs sensitive to diode capacitance, use the curve and measurement conditions when assessing the component rather than assuming the typical figure applies identically across all operating voltages.

Practical checks before selecting the diode

For an industrial control or automation circuit, evaluate the component in the context of the full electrical and thermal design. A selection review should include:

  • Voltage margin: Compare the circuit’s normal and transient reverse voltage with the 200 V reverse rating and 250 V peak rating. Do not exceed the peak limit.
  • Current profile: Check continuous or average current separately from peak and non-repetitive surge current. Confirm that any surge duration matches the specified one-second condition.
  • Power and temperature: Assess forward dissipation and the installation’s heat-removal conditions against the 400 mW rating and junction-temperature limit.
  • Switching requirements: Compare the circuit’s timing needs with the 100 ns maximum recovery-time specification, using its stated test conditions.
  • Package and polarity: Confirm the DO-35 footprint and cathode-band orientation against the board layout and assembly documentation.
  • Specification control: Verify the current product standard and availability before final design or purchase. The datasheet cautions that product specifications may change without notice.

Design within the specified operating range

The 1SS82 combines a 200 V reverse rating, moderate current limits, a specified recovery time and low typical capacitance in a DO-35 package. Those characteristics help define where it may be considered, but they do not by themselves establish suitability for a particular switching circuit. Engineers and system integrators should check actual voltage and current waveforms, thermal conditions, switching requirements and mounting details against the complete specification.

For plant and equipment designers, the practical takeaway is to treat every maximum rating as a design boundary and every electrical characteristic as condition-dependent. Confirm the latest specification before committing to a design, and include appropriate system-level safeguards where semiconductor failure could create consequential equipment or safety risks.