The HA17358 and HA17904 series are dual operational amplifiers designed for control equipment and general-purpose circuits. For engineers choosing a dual operational amplifier for an analog control stage, their stated features include internal phase compensation, high gain, single-supply operation and the ability to handle input signals around 0 V. The datasheet also reports output operation around 0 V, a characteristic that can matter in circuits referenced to ground.
These features are a starting point, not a substitute for checking the conditions behind each rating. The published electrical characteristics are given at defined supply, temperature and load conditions, while absolute maximum ratings describe limits rather than recommended operating points. Component selection should account for both distinctions.
HA17358 and HA17904: design features
Both series contain two operational amplifier channels. Internal phase compensation is included, and the devices are described as high-gain amplifiers. Single-supply operation is supported, which can simplify circuits that use one supply rail rather than separate positive and negative rails. The stated common-mode input capability allows operation with an input around 0 V, while the output can also operate around 0 V.
The datasheet further notes temperature compensation for frequency characteristics and input bias current. These are useful properties to consider in analog signal-conditioning and control circuits, but they do not remove the need to verify performance across the actual operating range. The listed electrical values vary by test condition, and the document provides separate characteristic information at 25°C and across a high-temperature range.
Pinout and channel arrangement
The eight-pin package assigns one output and two inputs to each amplifier, alongside the supply connections. In the top-view pin arrangement, channel 1 uses pins 1, 2 and 3 for output, inverting input and non-inverting input, respectively. Pin 4 is ground, pin 8 is VCC, and channel 2 uses pins 7, 6 and 5 for output, inverting input and non-inverting input, respectively.
Checking the pinout against the selected package and the board footprint is essential when replacing a component or adapting an existing circuit. The family is listed in DP-8 and FP-8D package options, so the package designation should be confirmed as part of the design review rather than inferred from the series name.
Electrical characteristics and operating limits
At VCC = +15 V and Ta = 25°C, the datasheet lists a typical input offset voltage of 3 mV, with a 7 mV maximum. Typical input bias current is 30 nA, with a 250 nA maximum, and typical voltage gain is 90 dB. These values describe performance under the stated test setup; they should not be treated as guaranteed values under every supply, load or temperature condition.
Other reported characteristics at these conditions include a typical power-supply rejection ratio of 93 dB and common-mode rejection ratio of 80 dB. The typical slew rate is 0.2 V/µs, and typical supply current is 0.8 mA, with a 2 mA maximum under the specified test condition. The listed peak-to-peak output voltage is typically 13.6 V with a 20 kΩ load at 100 Hz. Circuit performance will depend on the actual configuration and loading.
The common-mode input range is particularly relevant for single-supply designs. At the +15 V test condition, the datasheet gives a positive common-mode limit of 13.5 V and a negative limit of -0.3 V. A separate electrical-characteristics table for -40°C to +125°C lists a common-mode range of 0 V to 13.0 V. Engineers should use the figures that match the applicable variant and test conditions, and allow for the limits of the complete circuit.
Absolute maximum ratings are not operating targets
The absolute maximum supply voltage is listed as 32 V. This is a stress limit, not a recommended operating supply voltage. The datasheet excerpt does not provide a complete recommended supply-voltage range, so designers should consult the latest applicable product documentation before setting operating conditions. Other absolute maximum values include an output sink current of 50 mA and a common-mode input voltage range extending from -0.3 V to VCC. Exceeding absolute maximum ratings can place the device outside its specified limits.
Choosing a series and package variant
The ordering information distinguishes variants by application category and package. HA17358 and HA17358F are identified for commercial use. HA17904PS and HA17904FP are listed for industrial use, while HA17904PSJ, HA17904FPJ and HA17904FPK are listed for car use. The ordering table associates these options with DP-8 or FP-8D packages.
Temperature ratings differ among the listed parts. The HA17358 variants and the HA17904PS and HA17904FP are specified for an operating range of -20°C to +75°C. The HA17904PSJ and HA17904FPJ are listed for -40°C to +85°C, and the HA17904FPK for -40°C to +125°C. These differences make the exact part number important when matching a device to an enclosure, installation environment or application category.
Practical checks before design-in
- Confirm the exact variant: Check the ordering code, application category, package and operating-temperature range.
- Review the complete operating conditions: Do not interpret the 32 V absolute maximum supply rating as a normal operating voltage.
- Check signal and load requirements: Compare input common-mode levels, output swing, load and current needs with the relevant electrical-characteristics conditions.
- Account for thermal limits: Power dissipation depends on package and mounting conditions. The datasheet gives different dissipation ratings and derating guidance for different package conditions.
- Verify current documentation: The manufacturer advises confirming the latest product specifications before final design, purchase or use.
Conclusion
The HA17358 and HA17904 series offer two amplifier channels, internal phase compensation and single-supply capability, with input and output operation around ground noted as key features. Their usefulness in a control circuit depends on matching the specific variant to the required temperature range, package, signal levels, load and supply conditions. Treat absolute maximum values as limits, use electrical characteristics only with their stated test conditions, and verify current documentation before committing the device to a design.