Access Official Technical PDF

Share Summary:LinkedInEmail

Reducing the size, weight and energy losses of traction equipment is an ongoing consideration in railcar design. A SiC hybrid VVVF inverter developed for urban and commuter railways addresses these priorities through a combination of lower-loss semiconductor devices, a cooling system that uses airflow generated by train movement, and motor control that operates without a speed sensor. The inverter was applied to renovated 5000 Series railcars operated by Sanyo Electric Railway.

How the SiC hybrid VVVF inverter reduces losses

The inverter uses Fuji Electric-developed hybrid modules rated at 3.3 kV and 1,200 A. Each module combines silicon carbide Schottky barrier diodes (SiC-SBDs) with insulated gate bipolar transistors (IGBTs). This hybrid arrangement reduced semiconductor energy losses compared with a conventional silicon IGBT module.

In the reported comparison, average energy loss per element was 18% lower with the SiC hybrid module. This component-level reduction contributed to lowering losses in the propulsion inverter. For engineering teams assessing traction equipment, the result illustrates how the choice of semiconductor devices can affect both the electrical losses and the thermal requirements of an inverter system.

Cooling with airflow generated during travel

Reducing losses at the semiconductor level was paired with a change to the inverter’s thermal design. The cooling system uses a fin structure and the airflow created as the train travels to cool the inverter radiator. The design eliminated heat pipes, helping reduce the equipment’s volume and mass.

Together, the SiC hybrid modules and traveling-airflow cooling system enabled a 64% reduction in inverter volume and a 45% reduction in mass compared with the conventional product. These figures describe the inverter-level changes reported for this design; they should not be interpreted as equivalent reductions across the complete railcar or propulsion system.

Sensorless vector control for motor operation

The inverter also uses speed sensorless vector control. Instead of relying on an external speed sensor, the control system estimates motor speed from flux, using measured voltage and current. The estimated speed is then used in motor control.

Removing the speed sensor means the system does not depend on that separate device for speed feedback. The approach is intended to improve system reliability while maintaining control of the induction motors. In the main-track test, the estimated speed followed the actual speed during acceleration and deceleration, demonstrating that the sensorless control operated under the reported test conditions.

Application to Sanyo Electric Railway 5000 Series railcars

The inverter entered service in October 2018 as part of the renovation of Sanyo Electric Railway’s 5000 Series railcars. The six-car formation uses a 1,500 V DC overhead supply. The renovated train’s specified maximum speed is 110 km/h, and its traction motors are 180 kW induction motors.

As part of the work, Cars No. 1 and No. 2 at the Hanshin Umeda end were renovated. Car No. 1 was converted to a trailer, while the new VVVF inverter was installed on Car No. 2. The inverter uses a two-level configuration, with a 1C2M arrangement in two groups. The train combines regenerative braking with an electrically controlled pneumatic brake.

Main-track testing included acceleration and braking, with the railcars reaching the maximum operating speed of 110 km/h. The test data showed the estimated speed tracking actual speed during these operating conditions. This provided a practical check of the sensorless control alongside the performance of the renovated propulsion equipment.

Practical implications for rail propulsion design

This application brings together several design considerations relevant to railway traction systems:

  • Semiconductor selection: SiC-SBDs combined with IGBTs reduced module energy losses compared with a conventional Si-IGBT module.
  • Thermal management: A fin-based radiator cooled by traveling airflow eliminated heat pipes and supported a more compact, lighter inverter design.
  • Motor feedback: Speed estimation from voltage and current enabled vector control without an external speed sensor.
  • System validation: Main-track testing demonstrated acceleration and deceleration operation, including speed estimation through the test run.

For operators and integrators, the reported reductions in inverter size and mass are the combined outcome of the selected power devices, cooling arrangement and system design—not a result attributable to a single component alone. Likewise, the test results provide evidence for this specific railcar application rather than a universal performance guarantee for other vehicles or operating conditions.

Conclusion

The renovated 5000 Series application shows how power electronics, cooling and motor control can be considered together when updating rail propulsion equipment. The SiC hybrid VVVF inverter reduced energy losses at the module level and, with traveling-airflow cooling, achieved substantial reductions in inverter volume and mass. Sensorless vector control removed the need for an external speed sensor while tracking actual speed during main-track testing. These design choices offer a practical reference for teams evaluating compact traction systems for urban and commuter railcars.

Access Official Technical PDF

About The Author