Radiation monitoring in an accelerator environment involves two distinct questions: how much dose has equipment accumulated, and where and when is beam being lost? A development program at SOLEIL addressed these needs with separate systems for radiation dose monitoring and beam loss monitoring. The distinction matters: equipment exposure accumulates over time, while beam loss diagnostics must capture changing conditions, including fast events.

Both systems were designed around practical installation and operating requirements. Dose sensors needed to be compact and positioned close to vulnerable equipment. Loss monitors needed useful time resolution, relative calibration between detectors, and reduced sensitivity to synchrotron radiation.

Radiation dose monitoring with RadFET sensors

Accumulated radiation can contribute to premature damage in components such as insulators, bonding or baking films, electronics including CCDs, and permanent magnets. Estimating the dose received by these items can help facility teams assess exposure and plan equipment management. The SOLEIL work focused on a small, low-cost sensor that could be installed outside the vacuum chamber, as close as practical to the equipment being monitored, and provide an estimate of absolute dose.

The selected sensor type was a RadFET: a metal-oxide-semiconductor field-effect transistor optimized for radiation sensitivity. Radiation creates electron-hole pairs in the gate oxide, producing a permanent change. As the accumulated radiation dose increases, the transistor’s threshold voltage shifts. Measuring that shift provides a way to estimate exposure.

The work used TY1004 devices from Tyndall National Institute, each containing two identical RadFETs on one chip. During exposure, the pins are grounded, with gate bias available as a way to increase sensitivity. For readout, a 10-microamp current is applied between ground and source, and the corresponding threshold voltage is measured. Calibration curves supplied for sensors from the same batch were based on cobalt-60 irradiation.

Tests included installing RadFETs on a vacuum chamber exposed to synchrotron radiation at a beamline front end, and in the optic boxes of photon front ends. The reported measurements were preliminary, but they supported the principle of tracking cumulative dose in equipment locations. Further characterization remained necessary, including measuring fading—the reduction in recorded signal over time—and establishing the usable maximum dose. The devices were specified for 100 krad (1 kGy), with higher-range performance still to be investigated.

Automating RadFET readout

For monitoring to be useful in routine operations, sensors need a repeatable way to be read and their measurements made available to the control system. The project described an electronic crate under development for automated, periodic readings taken without beam. A multiplexed design was intended to connect several sensors to shared readout electronics, with capacity for eight dual RadFETs.

Automated measurements could make sensor characterization and ongoing dose tracking more manageable. At the time described, the readout electronics were at the prototype stage, so integration and further testing were still part of the development work.

Beam loss monitoring for fast and slow events

The existing SOLEIL beam loss monitors used coincident pin diodes. Their design made them insensitive to synchrotron radiation, but they were directional, operated in counting mode, and addressed slow losses. The proposed upgrade aimed to support both slow and fast loss observations and enable relative comparison between monitors, regardless of how they were installed or configured.

The detector concept reused an ESRF design: a 100 mm scintillation-plastic or quartz radiator paired with a compact Hamamatsu H10721-series photosensor and housed in an aluminum section. The test set included EJ-200 plastic scintillators and quartz rods for Cherenkov radiation, with different photosensor variants. Signals were acquired using Libera BLM electronics, which provided four 125 MHz, 14-bit digitizers, configurable data rates, detector power supplies, and postmortem data.

Relative calibration is essential because monitor readings can differ for reasons other than beam loss. Relevant factors include radiator or scintillator yield, photosensor sensitivity and gain, and attenuation in the electronics. The project investigated diode calibration using a 455 nm LED and gamma-source calibration using cesium. The diode method addressed photosensor sensitivity and gain dependence; the cesium-source method also included the scintillator yield. Source position was another consideration in interpreting the calibration results.

What early beam observations can reveal

Initial beam tests placed four monitors behind a vertical scraper. The arrangements varied photosensor type, radiator material, and lead-shield thickness. Measurements were examined as the scraper position changed, providing information related to the machine’s physical aperture. Other tests considered a nearby pinhole’s potential effect on readings, as well as fast losses during injection and vertical excitation with stored beam.

These observations illustrate why time-resolved loss data can complement slower operational indicators. Capturing loss signals and retaining postmortem data can help operations teams and machine physicists examine the timing and dynamics of events. However, comparisons between monitors depend on understanding detector response and the measurement chain, rather than assuming that identical signals represent identical losses.

Two monitoring systems, two operational purposes

RadFETs and beam loss monitors address related but different diagnostic needs. RadFETs provide an estimate of cumulative radiation exposure at equipment locations. Beam loss monitors are intended to help identify the location and dynamics of beam losses, including fast events, while supporting relative calibration across detectors.

For accelerator operators and technical teams, the practical implication is to match the measurement method to the question. Dose tracking can inform decisions about radiation-exposed components, while calibrated, time-resolved loss monitoring can support operations and machine studies. At SOLEIL, the reported work represented development and preliminary testing, with sensor characterization, readout electronics, and further validation still required.