Access Official Technical PDF

Share Summary:LinkedInEmail

CDM ESD testing helps determine how sensitive a discrete semiconductor is to electrostatic discharge when the device itself becomes charged and then discharges to a grounded conductor. For automotive component qualification, AEC-Q101-005 Rev-A establishes a consistent approach by applying the ANSI/ESDA/JEDEC JS-002 device-level method alongside additional requirements for preparation, measurements, stress conditions, acceptance, and reporting. These details matter to component engineers, test laboratories, and qualification teams seeking results that can be assessed consistently.

How AEC-Q101-005 defines CDM ESD testing

The purpose of the method is to provide a reliable and repeatable procedure for determining charged device model sensitivity in discrete semiconductors. Rev-A identifies ANSI/ESDA/JEDEC JS-002 as its reference specification and adds requirements that apply to AEC-Q101 qualification. The document is therefore not a replacement for JS-002: testing is conducted according to the latest version of that specification, with the clarifications and requirements set out in AEC-Q101-005.

In a CDM event, the device under test (DUT) is charged and then discharged through a selected pin or terminal. The method requires all device pins, including power and ground pins, to be addressed at the specified test condition and polarity. Following a defined procedure helps ensure that test outcomes reflect the device response rather than inconsistent handling or setup.

Prepare the tester, devices, and measurements

Preparation begins with unused test samples: devices selected for CDM stressing must not have been used in prior stress tests. ESD damage-prevention procedures apply before, during, and after stressing and post-test parametric measurements. Devices must be clean, and the tester probe, field plate, and dielectric must be clean and dry. If cleaning is needed, it should follow approved procedures; the document notes that isopropanol is typically used and that surfaces must be allowed to dry.

Tester settings also require control. Field plate voltage factors and voltage offsets are determined during full qualification of the CDM test system. They must not be adjusted in response to routine waveform verification or product test waveforms or results. The settings established during qualification are used across product test conditions, with separate uniform offsets for positive and negative stresses determined through the specified qualification procedure.

Before stressing, each device receives initial electrical verification according to its user device specification. Measurements are performed at room temperature followed by hot temperature unless that specification says otherwise. A device-level data log records the applicable parameters so initial results can be compared with final measurements after exposure.

Sample size, discharges, and test options

Each sample group contains ten devices for one stress test condition. Every pin or terminal is stressed at that condition, and a new group of ten is required for each condition. The method requires three discharges at each stress level. Testing may apply three positive discharges followed by three negative discharges, or use three alternating sets of positive and negative discharges. The applicable single- or dual-discharge procedure is detailed in JS-002.

AEC-Q101-005 describes three ways to organize the test sequence:

  • Separate groups by condition: Use a different sample group for each classification test condition, then conduct functional testing.
  • Progressively increase the stress: Begin at the lowest starting condition, test, and advance passing samples—or fresh samples—to the next higher condition. Continue until a failure occurs or samples pass TC 1000.
  • Follow the recommended flow: Apply the specified test flow, starting at positive TC 500, and repeat the required stressing and verification steps across pins, polarities, devices, and subsequent test conditions.

The chosen option should be clear in the test plan and report. In all cases, the procedure must account for the specified stress levels and polarities and include final electrical verification.

Classify results using failure and acceptance criteria

A device is considered a failure if it exceeds the allowable shift for a key parameter or no longer meets its user device specification. The listed key parameters are leakage-related measurements: ICES, ICBO, and IEBO for bipolar devices; IDSS and IGSS for FETs; ICES and IGES for IGBTs; and IR for diodes. For these listed parameters, the maximum allowable shift is ten times the initial measurement. The user device specification may define other parameters and allowable shifts.

A stress condition passes only when all devices stressed at that level and at lower levels meet the measurement and failure requirements. The supplier then assigns a classification based on the maximum withstand test condition:

  • C0a: below TC 125
  • C0b: TC 125 to below TC 250
  • C1: TC 250 to below TC 500
  • C2a: TC 500 to below TC 750
  • C2b: TC 750 to below TC 1000
  • C3: TC 1000

The specification cautions that, above TC 1000, package geometry may allow corona effects to limit the actual pre-discharge voltage and discharge current. It also notes that changes to manufacturing process, design, materials, or package may require the device to be reclassified.

Account for package and reporting limitations

Very small packages can be difficult to test. Vacuum may not hold packages with only a few square millimeters of area effectively, while low capacitance between the DUT and field plate produces very fast, narrow current pulses. The document explains that these pulses can be difficult to measure with standard 1 GHz measurement systems. Because testing may not be practical for some very small packages, supplier and customer agreement may be needed. Any device or package that could not be completely stressed must be recorded.

For wafers or bare die, the method can be used for evaluation, but standardized CDM stressing is not defined because of equipment limitations. Bare die may be placed in a package for stressing when appropriate, based on package test limitations and supplier-customer agreement. The package used must be documented.

When requested, the test report should describe the samples, methods, conditions, and results, including deviations. Useful details include package configuration and sample size; discharge method and test-condition levels; pin partitioning and package orientation; and any exceptions, small-package considerations, or use of a surrogate package for wafer or bare-die testing.

Practical implications for qualification teams

A sound CDM qualification plan combines controlled tester settings, traceable initial and final measurements, clearly defined sample groups, and consistent application of stress conditions. Teams should agree in advance on the test option, treatment of package limitations, and reporting expectations. Following the AEC-Q101-005 additions to JS-002 gives suppliers and customers a shared basis for interpreting discrete semiconductor CDM results and determining when a device’s classification may need to be revisited.