A dual flyback inverter (DFBI) is a single-stage DC-to-AC topology intended for isolated, low-power photovoltaic microinverter applications. Its appeal is a relatively simple circuit with a reduced component count, while supporting both active and reactive power generation. Analysis and prototype results show how duty-cycle control, switching frequency and device selection shape its performance—and where designers must account for practical trade-offs.

How a dual flyback inverter produces AC output

The DFBI is derived from a boost-type inverter arrangement. In place of the two inductors used in that arrangement, the topology uses flyback transformers. This substitution provides galvanic isolation between the input and output, an important consideration in PV systems.

The inverter creates an AC output by controlling the voltages on two output capacitors, C1 and C2. Each voltage has a positive DC offset, with a sinusoidal component that moves in the opposite direction to the other. Subtracting the capacitor voltages produces the AC output without a DC offset:

uAC(t) = uC1(t) − uC2(t)

In practical terms, the control system must shape both capacitor voltages so their difference follows the required waveform. For island operation, this means maintaining a suitable output voltage as input voltage and load conditions change. The required voltage control is therefore a central part of making the power stage useful, not an optional refinement.

Duty-cycle control and operating limits

Duty cycle governs the converter’s DC voltage-transfer characteristic and, in turn, the voltage available from each flyback stage. State-space analysis can be used to derive this relationship and identify operating regions that may be unsuitable. Because the transfer characteristic is nonlinear, a particular output-voltage target does not translate into a simple, constant relationship across all operating conditions.

The control approach uses duty-cycle modulation to make the two capacitor voltages follow complementary squared-sinusoidal references. Their difference forms the desired sinusoidal AC voltage. The DC offset must also be selected appropriately to prevent uncontrolled charging of the capacitors from the input source.

The analysis identifies a critical duty cycle of approximately 0.85 under nominal load, which should not be exceeded. Separately, the reported efficiency analysis indicates that the nominal-load duty-cycle range can be optimized from 0.2 to 0.6. These values are design guidance from the analyzed converter; the operating point still depends on the application’s voltage, load and circuit parameters.

Active clamp, SiC devices and efficiency

The investigated design combines an active clamp with quasi-resonant switching circuitry and silicon-carbide (SiC) devices. The purpose of examining these design choices is to understand how an established, relatively simple topology can be improved without relying solely on more complex converter architectures.

Experimental work used SiC MOSFETs and evaluated the inverter at switching frequencies of 48 kHz, 67 kHz and 100 kHz. The frequency choices represent a compromise between the size of energy-storage components—including the flyback transformers, resonant inductor and capacitors—and switching-related power losses. In particular, the analysis highlights losses associated with the secondary-side S3 switch during reverse recovery of its body diode.

The prototype reached a reported peak efficiency of 94%. This result applies to the tested configuration; it should not be treated as a guaranteed efficiency for other designs or operating points. The analysis also identifies secondary rectification by S3 as particularly important to efficient operation. This makes device and rectifier selection a significant part of the design process, alongside the choice of switching frequency and clamp circuitry.

Waveform quality and reactive power operation

Measured results demonstrate that the DFBI can provide an AC output and operate in both active- and reactive-power modes. At 100 W, with a 230 V AC output and a resistive load, the reported output-voltage total harmonic distortion (THD) was 6%. A separate test demonstrated reactive power generation with a series R-C load: the reported values were 230 V AC, 75 W active power and 81 VA apparent power.

These results illustrate why output control must be considered together with converter topology. In island operation, voltage regulation must keep the waveform within operating limits as load and input conditions vary. The reported tests establish the prototype’s demonstrated operating points, rather than defining performance under every possible load or system condition.

Transformer sizing is a key trade-off

The topology’s relative simplicity and isolation come with a magnetic-component trade-off. Each flyback transformer must be dimensioned for twice the AC output power, according to the analysis. This requirement arises from the instantaneous power pulsation of the flyback converters over the AC output-voltage period and can increase transformer size.

For system integrators and design teams, this means component count alone is not a sufficient measure of converter practicality. Transformer sizing, switching losses, capacitor energy, duty-cycle limits and output control all need to be assessed together. The appropriate balance depends on the intended power level and operating conditions.

Practical implications for PV inverter design

The dual flyback inverter offers a compact conceptual route to isolated DC-to-AC conversion, with the ability to generate active and reactive power. The demonstrated prototype combined an active clamp and SiC switching devices, reaching a peak efficiency of 94% and producing a measured output-voltage THD of 6% at the stated test condition.

Those results should be weighed against the topology’s constraints: a nonlinear voltage-transfer characteristic, a critical duty-cycle limit, switching-related losses and comparatively demanding transformer sizing. For engineers evaluating a PV microinverter, the practical lesson is to validate the full operating range—not just peak efficiency—including voltage regulation, waveform quality, load behavior and magnetic-component requirements.