Electrostatic discharge (ESD) can damage electronic components during manufacturing, assembly, inspection, testing, packaging, service and transport. Because static charge can arise through contact and separation of materials or the movement of solids, liquids and particle-laden gases, managing ESD requires more than installing a grounding point at a workstation. An effective ESD control program brings together defined procedures, suitable technical controls, employee training and ongoing verification.
IEC TR 61340-5-2 provides guidance for developing and monitoring a program aligned with IEC 61340-5-1. Its central lesson for operations teams is that controls should reflect the products and processes being handled, be documented clearly and be checked over time.
Build the ESD control program around process risk
ESD exposure can occur in a range of activities, including handling electronic parts and assemblies, packaging products, testing equipment and moving items through a facility. Common sources include people, conductive objects, polymeric materials and processing equipment. A discharge may happen when a charged person or object contacts a sensitive device, when a device encounters a conductive surface while exposed to an electrostatic field, or when a charged device meets a surface at a different electrical potential.
These different paths matter because ESD prevention is not a single-control problem. Organizations should identify where sensitive items are handled and consider the materials, equipment and people present at each step. The resulting control measures should be selected for technical need and recorded in an ESD control program plan, so operators, supervisors and support teams can understand what is required.
IEC guidance uses baseline susceptibility levels of 100 V for the human body model (HBM), 200 V for the charged device model (CDM) and 35 V for isolated conductors. These levels inform the controls described in the guidance; they are not a substitute for understanding the susceptibility of the specific devices being handled. Where products have lower withstand levels, the organization may need additional controls or adjusted limits, documented in its program.
Document ownership, training and verification
A written plan gives the ESD program a working structure. It should describe the program’s scope and responsibilities, applicable technical controls, training approach, product qualification and compliance verification. Assigning an ESD coordinator helps establish clear ownership for maintaining the plan and supporting its implementation.
Training is an operational control, not an administrative formality. Employees need to understand the ESD risks relevant to their work and how to use the equipment and procedures specified by the plan. Initial and refresher training can help maintain that awareness as responsibilities or processes change. When personnel understand the purpose of the controls, they can help identify practices that might introduce risk rather than relying solely on equipment to prevent damage.
Compliance verification checks whether equipment remains effective and whether the program is being followed. A planned approach makes checks repeatable and supports trend review, rather than treating an inspection as a one-time activity. The plan should identify what is checked and how results are recorded, with procedures appropriate to the controls in use.
Ground conductors and protect the work area
A core ESD control principle is to avoid a discharge from a charged conductive object into a sensitive device. Connecting conductors to a known ground, or to an appropriate equipotential bonding system, helps bring people and equipment to the same electrical potential. Where grounding to earth is not available, a suitable contrived ground may be used in some environments. The essential principle is that relevant conductive items are maintained at an equipotential state.
Grounding must be designed as a system. The guide illustrates individual grounding of benches as the recommended approach and cautions against connecting benches in series. This distinction reinforces the need to plan workstation connections rather than assume that one grounding path will reliably protect every station.
Within an ESD protected area (EPA), the program also needs to address personnel grounding, work surfaces and materials. Insulators require particular attention: unlike conductors, they cannot be neutralized simply by connecting them to ground. Remove unnecessary insulators from the vicinity of sensitive items where practical. If an insulator is essential to the process or product, assess the hazard and use appropriate mitigation, such as ionization where suitable.
Match packaging to where products are handled
Controls inside an EPA and protection during shipment or storage are related, but they are not interchangeable. Low-charging and static-dissipative materials may provide adequate protection in an EPA, depending on the application. Outside the protected area, the guidance recommends low-charging and static-discharge-shielding packaging for ESD-sensitive products. Packaging selection should account for the handling environment and destination, and the program should make the required approach clear to the people who pack and move products.
Marking also supports consistent handling by identifying ESD-sensitive items and indicating special precautions. Labels cannot replace protective packaging or work-area controls, but they can communicate that an item needs attention as it moves between processes or teams.
Apply controls consistently, then review them
Automated handling equipment, gloves, finger cots and hand tools can all form part of an ESD control strategy. Their suitability should be evaluated and qualified for the intended use rather than assumed based on appearance or material description. The IEC guide addresses testing considerations for these items, underscoring that accessories and equipment used near sensitive devices belong within the program’s control and verification framework.
For plant managers and engineering teams, the practical priority is to connect each control to a documented process requirement: define who is responsible, train the people involved, select and qualify appropriate equipment, and verify that controls continue to work. Where device sensitivity falls below the guide’s baseline levels, assess whether the established limits remain appropriate and record any changes.
A reliable ESD control program is therefore an operating system for managing electrostatic risk, not just a collection of mats, straps and labels. By combining grounding and equipotential bonding, EPA practices, packaging, personnel training and regular compliance checks, organizations can apply controls consistently across product handling. Clear documentation and review help ensure those controls remain aligned with the devices and processes they are intended to protect.