An LED linear module can simplify luminaire design, but successful integration depends on more than light output. Engineers and system integrators need to account for the module’s electrical drive conditions, thermal limits, mounting dimensions, and handling requirements. Seoul Semiconductor’s SunLike Linear Reference Module is a 560 mm lighting engine intended for residential, commercial, and linear highbay applications, with several correlated color temperature (CCT) options and a color rendering index (CRI) of 95.

LED linear module design and light quality

The SMJD-2423072G-XXN1 uses a Zhaga-standard mounting pattern and industry-standard mechanical attributes. Its 560 mm by 18 mm footprint is designed for linear luminaire layouts; the module is 5.4 mm high, with a 1.0 mm PCB thickness. Published dimensional tolerances are ±0.5 mm for length, ±0.3 mm for width and height, and ±0.1 mm for PCB thickness.

Light quality is a central feature of the module. The specified CRI is at least 95, while the listed 3-step MacAdam color range helps define the permitted chromaticity variation for each CCT. Available nominal CCT choices are 2700 K, 3000 K, 3500 K, 4000 K, 5000 K, and 6500 K. These options allow a luminaire designer to select warmer or cooler white light without changing the module’s overall form factor.

At the listed 900 mA test current and 25°C ambient temperature, the product selection table gives minimum and typical flux values by CCT. The 2700 K, 3000 K, and 3500 K versions are listed at 1,800 lm minimum and 2,000 lm typical. The 4000 K, 5000 K, and 6500 K versions are listed at 2,000 lm minimum and 2,200 lm typical. Typical efficacy is stated as 90 lm/W for the lower-CCT H, G, and F bins, and 95 lm/W for the E, C, and A bins.

Electrical specifications and driver selection

The module is designed for DC operation and should be driven with a constant-current source (CCS). At 900 mA, the listed forward-voltage range is 23–26 V, with a typical value of 24 V; the document also identifies 29 V as the maximum forward voltage. Electrical design should follow the applicable limits in the product specification, including the maximum output voltage of the selected driver.

The electro-optical data at 900 mA lists power consumption of 20–26 W, depending on the specified range. Separately, the maximum operating specification lists 35 W at a driving current of 1,350 mA. These figures refer to different operating conditions, so the design team should use the relevant ratings for its intended drive point rather than treating them as interchangeable. The document recommends a qualified LED driver and cautions against output overshoot.

The module does not have a built-in current regulator. When multiple engines are connected in parallel, forward-voltage variation can result in uneven current loading. Driver and circuit design therefore need to account for current regulation and the intended connection arrangement. The product is not an SELV engine: do not connect the LED driver to mains power while wiring or assembling the module.

Thermal management and operating limits

Thermal conditions affect whether the module remains within its operating specification. The stated operating temperature range is −40°C to 98°C, measured at the assigned Tc point on the PCB. The manufacturer specifies that Tc must remain below 98°C for proper operation. The listed thermal resistance from Tc to the base is 0.3°C/W.

For fixture design, this makes the specified Tc measurement point important: ambient temperature alone does not confirm that the module is within its limit. Engineers should assess the assembled luminaire under its intended operating conditions and keep the module’s Tc below the stated maximum. The specification also lists a storage temperature range of −40°C to 98°C when the module is unpowered.

Handling, ESD, and installation precautions

LED components can be damaged by electrostatic discharge (ESD) or electrical overstress (EOS), and the resulting problems may not always appear as a complete failure. The guidance identifies possible symptoms such as altered light output, flicker, abnormal electrical behavior, or degraded performance. Recommended ESD controls include antistatic work surfaces and storage containers, ionizing fans, wrist straps, antistatic clothing or footwear, and humidity control.

To reduce the risk of electrical overstress, use a suitable driver with controlled output and a current-limiting device. During assembly and maintenance:

  • Check the module’s appearance before wiring; do not use it if the lens is cracked or wiring is damaged.
  • Observe DC polarity and avoid connecting the driver to mains while wiring.
  • Do not detach the lens, modify the module, or allow the lens to contact rough or sharp objects.
  • Avoid using the module with materials containing sulfur.
  • Do not extend the cable excessively, as the guidance cautions against prolonged use with an overly long cable.

For long-term storage, keep the module in its antistatic bag. If the bag has been opened, reseal it to limit exposure to air and moisture, and avoid impact or pressure on the product.

Planning a SunLike module integration

The SunLike module brings together a linear form factor, high color rendering, multiple CCT selections, and specified mounting dimensions. For a practical design review, confirm the required light output and CCT, select a constant-current driver suited to the chosen operating point, and verify both voltage limits and thermal conditions at the module’s Tc point. Include ESD and EOS controls in assembly and service procedures, and preserve the lens and module wiring during handling.

These checks help translate component specifications into a sound luminaire design. The key takeaway is to treat the LED linear module as part of a complete electrical, thermal, mechanical, and handling system—not as a light source that can be selected by lumen output alone.