A well-designed AC-DC supply must balance conversion efficiency, power quality, transient response and safe operation across changing loads. This 240 W reference design for All-in-One PCs and similar 12 V equipment brings those demands together with a power factor correction (PFC) front end, an LLC resonant converter and secondary-side synchronous rectification. Its control architecture offers useful lessons for engineers assessing high-efficiency power conversion and for teams adapting a power supply evaluation board to a target system.

How the 240 W power supply is organized

The design accepts a universal 90–265 VAC input and provides a nominal 12 VDC output at up to 20 A. Its principal conversion stages are a critical-conduction-mode PFC boost stage followed by a half-bridge LLC power stage. On the secondary side, synchronous rectification reduces conduction losses compared with using conventional rectifier diodes.

The PFC stage shapes the input current and regulates the high-voltage DC bus used by the LLC converter. The reference design describes its goal as near-unity power factor with low total harmonic distortion. The LLC stage then converts energy from the bus to the isolated low-voltage output, while secondary-side feedback maintains output regulation.

Reported board parameters include a full-load output ripple below 150 mV, an operating-temperature range of 0–40°C, and a compact board measuring 194 × 108 × 27 mm. The stated four-point average efficiency at 230 VAC is 94.11%. These are reference-design figures, not guarantees for a modified design or a finished product.

What current-mode LLC control changes

The NCP13992 controls the half-bridge resonant stage. In this current-mode approach, switching frequency is derived from the resonant-capacitor voltage signal and the feedback level, rather than being set through a conventional voltage- or current-controlled oscillator. The controller monitors the resonant signal as an indirect indication of primary current and adjusts operation in response to output feedback.

Compared with traditional voltage-mode control, the design documentation identifies improved line and load transient response and inherent protection against operation outside zero-voltage switching as benefits of the current-mode technique. These features are relevant where a supply must respond to changing equipment demand while managing switching behavior.

The NCP13992 also integrates high-voltage gate drivers and high-voltage startup, reducing the need for some external circuitry. Its protection and control functions include overload and overcurrent protection, brown-out detection, open-optocoupler detection, automatic dead-time adjustment, and overvoltage and overtemperature protection. A dedicated output can control the PFC controller, supporting coordinated operation of the two stages.

Coordinating PFC and light-load operation

At light load or no load, the design uses skip and standby behavior to reduce unnecessary switching activity. The LLC controller’s mode signal coordinates the PFC stage: during LLC skip operation, it can place the PFC controller into standby. The design also uses a restart-level adjustment as part of its hiccup behavior, supporting low no-load consumption.

The measured data show how input voltage and load affect the reported results. At 230 VAC, the board’s four-point average efficiency is 94.11%, compared with 92.73% at 120 VAC. At 20 A full load, the reported efficiencies are 94.5% at 230 VAC and 92.57% at 120 VAC. Measured no-load consumption is below 125 mW at 230 VAC and below 115 mW at 120 VAC across the reported board tests.

These figures help characterize the particular evaluation design; they should not be treated as universal performance expectations. Component selection, layout, cooling and system-level operating conditions all matter when translating a reference circuit into an application.

Synchronous rectification and output regulation

Two NCP4306 synchronous-rectifier controllers operate the secondary-side MOSFET channels. Each channel uses parallel MOSFETs, and snubber networks damp parasitic ringing to limit peak voltage across the rectifiers. The controllers’ light-load detection feature enables them to enter a low-power state between bursts and prepare for operation when switching pulses resume.

Minimum on-time and off-time settings help prevent false triggering from ringing in the rectifier power stage. This detail illustrates an important practical point: synchronous rectification depends not only on low-resistance switches but also on reliable timing and noise management, particularly as operating conditions change.

Output voltage is regulated by an NCP431 shunt regulator and an optocoupler feedback path. A separate secondary-side overvoltage sensing circuit uses another NCP431 reference and an optocoupler to report a fault to the primary-side controller. Output capacitors provide bulk filtering, while an optional output inductor and capacitor help smooth switching-related disturbances.

Design and integration considerations

The board includes filtering, startup and sensing functions alongside the power stages. Its input EMI filter is followed by the PFC boost stage; the PFC controller also supports X2 capacitor discharge and contributes to startup and input-voltage sensing. The documentation notes that the demo revision substitutes a strap for the inrush-limiting resistor, which can be replaced with an appropriate NTC limiter if needed.

Thermal and mechanical integration also require attention. The board is intended for open-frame use with natural airflow. At full load and an ambient temperature of 25°C, the LLC transformer temperature is reported to reach approximately 90°C. The design documentation therefore advises considering forced airflow if the board is enclosed. It also describes the board as an engineering evaluation platform, not a finished consumer product; any adaptation must be validated for its intended application.

Practical implications

This reference design demonstrates how PFC, current-mode LLC control, synchronous rectification and coordinated light-load behavior can be combined in a compact 12 V supply. For engineering teams, its value lies not only in the headline efficiency figures but in the implementation details: sensing and feedback paths, noise filtering, protection coordination, rectifier timing and thermal management. Treating these elements as an integrated system—and validating the resulting design under its actual electrical and mechanical conditions—is essential when adapting an evaluation board for production equipment.