Millimeter-wave four-wave mixing is a key nonlinear process for developing superconducting quantum devices at frequencies around 100 GHz. A study of thin-film niobium nitride (NbN) resonators demonstrates how kinetic inductance can provide that nonlinearity without relying on Josephson junctions. The results also highlight practical design considerations: film quality, resonator losses, wire geometry, and measurement conditions all influence device behavior.
For engineers and technical decision-makers working with advanced materials and high-frequency systems, the work offers a useful example of how material properties become system-level constraints. The devices were characterized near 1 K, and the measurements included resonator quality factors, power-dependent frequency shifts, and parametric conversion.
Why use millimeter waves for quantum devices?
Millimeter-wave photons have higher energy than microwave photons. In superconducting quantum systems, operation at these frequencies could support experiments at temperatures above 1 K, compared with the millikelvin temperatures commonly used for microwave quantum circuits. The frequency range also opens opportunities to investigate light-matter interactions and frequency conversion.
Realizing these systems requires more than operating at a higher frequency. Components must have sufficiently low loss and long photon lifetimes, while also providing the nonlinear interactions used in circuit quantum optics. At microwave frequencies, Josephson junctions are a well-established source of nonlinearity. At millimeter-wave frequencies, device materials must also account for the risk that high-frequency photons can break Cooper pairs. Kinetic inductance offers an alternative approach based on the inertia of Cooper pairs in a superconductor.
How kinetic inductance produces nonlinearity
Kinetic inductance is the contribution to inductance associated with the motion of Cooper pairs. In a thin superconducting film, this contribution can be substantial. It also varies with current: as current increases, the kinetic inductance changes, shifting the resonator’s frequency. This current-dependent response gives the resonator a Kerr nonlinearity, meaning its frequency changes with the number of photons stored in it.
That behavior enables four-wave mixing. With a strong pump tone applied to a nonlinear resonator, energy can be transferred into signal and idler tones. In the degenerate process measured in this work, two pump photons are converted into a signal photon and an idler photon, with the signal and idler frequencies arranged around the pump frequency. This interaction is a building block for parametric amplification and other nonlinear quantum functions.
NbN films and resonator performance
The resonators were fabricated from NbN films grown by atomic layer deposition (ALD), a method of depositing thin material layers. The films ranged from 20 to 50 nanometers thick and were patterned on sapphire substrates. Their measured critical temperatures reached 13.9 K, and the sheet inductance reached 212 picohenries per square. Sheet inductance increased as film thickness decreased, making thinner films attractive for achieving stronger kinetic-inductance effects.
However, increased inductance does not eliminate the need to manage loss. The researchers measured internal quality factors from 10,000 to 60,000 for films thicker than 20 nm. The internal quality factor, or Qi, describes energy loss within the resonator: higher values indicate lower internal loss and longer energy storage. At low power, Qi increased as power rose, a pattern consistent with saturation of two-level-system losses, potentially associated with amorphous surface oxide. At higher power, the quality factor approached a limit, suggesting other power-independent losses, such as dielectric or radiative loss, could become dominant.
Film thickness was not the only factor under consideration. The study discusses disorder-related losses and trapped magnetic vortices as possible contributors to dissipation. Devices were not shielded from magnetic fields while cooling through their superconducting transition, a condition that could allow vortices to become trapped. These mechanisms underline why material characterization and measurement environment matter alongside resonator design.
Geometry controls the Kerr response
The team characterized kinetic-inductance nonlinearity by measuring how the resonant frequency shifted as the average photon number changed. For a resonator made from a 29-nanometer film with a 0.5-micrometer wire width, the measured self-Kerr coefficient was 1.21 kHz. The results showed that narrower wires produced stronger nonlinearity, consistent with the expected inverse-square relationship between wire width and self-Kerr strength.
Photon-number estimates carried a multiplicative uncertainty of about a factor of 10, reflecting limits in calibrating power delivered to the device. This is an important measurement consideration: a clear nonlinear response can be observed while the absolute estimate of stored photons remains less precise. The study also found that wire width did not show a significant impact on the internal quality factor in the tested devices.
Demonstrating parametric conversion at 95 GHz
Two-tone measurements demonstrated degenerate four-wave mixing in a 95-GHz device. A strong pump drove the resonator while a lower-power signal was applied at a frequency offset. As pump power increased toward the resonator’s bifurcation point—the threshold where its nonlinear response can become multivalued—the measured forward conversion efficiency rose to as much as +16 dB.
The conversion response agreed with an analytical model of the nonlinear resonator. The observed gain was limited in part by losses, emphasizing that stronger nonlinearity alone is not sufficient: useful parametric operation depends on balancing nonlinear coupling with resonator dissipation.
Practical implications for high-frequency device development
This demonstration establishes that ALD-grown NbN resonators can combine measurable quality factors with kinetic-inductance nonlinearity at millimeter-wave frequencies. For development teams, the central lesson is to treat film properties, geometry, loss mechanisms, and test setup as interdependent design variables. Thinner films can increase sheet inductance, while wire width can tune nonlinearity; meanwhile, disorder, surface-related losses, and magnetic-field exposure can affect resonator performance.
The demonstrated conversion does not by itself constitute a complete quantum system or establish a finished amplifier design. It does, however, provide a basis for developing nonlinear components for high-frequency quantum experiments, including potential parametric amplifiers, frequency converters, and other devices identified by the researchers. Progress will depend on preserving low loss while engineering adequate nonlinearity and reproducible fabrication.