Access Official Technical PDF

Share Summary:LinkedInEmail

Millimetre-wave biological effects are relevant to more than medical research. Millimetre-wave (MMW) and terahertz (THz) technologies are used or investigated for applications that include industrial non-destructive inspection and biomedical imaging. As interest in these frequency bands grows, engineers and technical decision-makers need to distinguish between a measured biological response and evidence of a predictable, useful—or harmful—effect.

A review of experimental studies found indications that MMW and THz exposure can influence biological systems in ways not clearly explained by tissue heating. It also found that the evidence is too limited and inconsistent to support broad conclusions about how these effects occur, which exposure conditions matter, or whether they can be used therapeutically. For technology developers, the practical message is that exposure characterization and experimental controls are central to interpreting results.

What millimetre and terahertz waves mean

MMW generally refers to electromagnetic frequencies from 30 to 300 GHz, corresponding to wavelengths of roughly 1 to 10 millimetres. THz radiation is typically described as extending from 300 GHz to 10 THz or higher, with wavelengths between about 15 micrometres and 1 millimetre. The boundary is not always applied consistently across published studies, so frequency ranges and terminology need to be reported clearly.

These bands have different interactions with materials and biological tissue. THz imaging, for example, can reveal contrast associated with differences in tissue water content and structure. MMW exposure is absorbed primarily near the skin surface, with penetration described in the review as a few tenths of a millimetre. Those physical characteristics matter when designing exposure systems, selecting dosimetry methods and interpreting measured outcomes.

Millimetre wave biological effects: what studies report

The review identified 81 publications on MMW exposure, including in vitro work with cells and in vivo studies using living organisms. Reported endpoints covered a wide range: cell viability and proliferation, gene and protein expression, DNA integrity, metabolism, nerve function, immune responses and organ-level outcomes. Many studies reported biological responses under conditions their authors considered non-thermal.

However, a reported response is not, by itself, proof of a robust non-thermal mechanism. A small temperature change can be biologically relevant, and attributing an outcome to a non-thermal interaction depends on reliable temperature control as well as accurate exposure measurement. The review found no consistent relationship between responses and frequency, power density or exposure duration across the MMW studies. The diversity of biological endpoints also made comparisons difficult: studies labelled as examining gene expression, for example, did not necessarily investigate the same genes or use comparable methods.

Some reports have described pain-related effects, while therapeutic MMW use has also been reported in particular settings. The review emphasized important limitations in the clinical evidence, including a lack of well-controlled, double-blind trials and an incomplete explanation for how localized skin exposure could affect broader conditions. These findings therefore should not be taken as confirmation of clinical effectiveness.

Terahertz evidence remains more limited

The review identified 36 THz publications, including only four in vivo studies. Most of the experimental work was conducted in vitro, and studies varied in frequency, power density, exposure duration and biological endpoint. Some reported changes in outcomes such as cell proliferation, gene expression or cellular stress responses. The small and heterogeneous evidence base prevents reliable conclusions about whether particular exposure conditions are more likely to produce an effect.

THz research also illustrates why an apparent pattern needs cautious interpretation. Some in vitro results suggested more responses at higher power densities, but the number and comparability of studies were insufficient to establish a dependable dose-response relationship. THz radiation has also been investigated for imaging, where contrast can arise from tissue properties such as water content. Diagnostic contrast and a biological response to exposure are different questions and should not be conflated.

Experimental controls determine how much results can tell us

To evaluate possible non-thermal effects, the reviewed studies were assessed for core quality measures. These included sham exposure, dosimetry, temperature control, positive controls and blinded analysis. Sham exposure helps distinguish the effect of the field from other aspects of the experimental setup. Dosimetry describes the exposure delivered to the sample or organism. Temperature control helps test whether heating could account for an observed response.

These measures were not consistently present. In the MMW studies, temperature controls appeared in about two-thirds of the work, while blinded protocols were uncommon in vitro. THz studies also had gaps: although many included sham conditions, fewer reported dosimetry or temperature control, and none of the reviewed investigations used blinded analysis. Missing controls do not prove that a reported result is wrong, but they make it harder to determine its cause and reproduce it independently.

For engineers and research teams developing exposure equipment or test methods, this points to practical priorities:

  • Document frequency, power density and exposure duration precisely.
  • Use dosimetry appropriate to the frequency range and experimental setup.
  • Include sham-exposed controls and monitor temperature under relevant conditions.
  • Use positive controls and blinded analysis where appropriate.
  • Define biological endpoints clearly enough for independent replication.

Safety and application implications

Biological-effect studies can help explain how electromagnetic fields interact with living systems. Health-effect studies, by contrast, assess outcomes at the organism level and contribute to evaluating safe exposure levels. Both depend on sound experimental methods. The review also noted that dosimetry metrics vary across the electromagnetic spectrum: incident power density is used for MMW, while the appropriate metric for THz exposure remained under discussion in the literature considered.

Consequently, results from one frequency band or exposure arrangement cannot automatically be transferred to another. Safety guidance for THz was also described as lacking frequency-specific experimental foundations, with estimates drawing on neighbouring regions of the spectrum. This makes clear reporting and targeted research important for both technology assessment and the development of evidence-based exposure guidance.

Conclusion: treat the evidence as a research signal, not a settled mechanism

The reviewed literature provides some evidence that MMW and THz exposure may affect biological systems in ways not obviously driven by tissue heating. But the number of relevant studies—particularly for THz—is limited, methods and endpoints vary, and specific interaction mechanisms remain unresolved. No consistent pattern establishes which frequencies, power densities or exposure durations are most important.

For industrial automation and technology teams, the implication is not to assume either a therapeutic effect or a demonstrated non-thermal hazard. Instead, evaluate claims against exposure data, temperature controls, appropriate dosimetry and independent replication. Better-standardized experiments are a prerequisite for determining whether reported responses are reproducible and relevant to health or future applications.

Access Official Technical PDF