Access Official Technical PDF

Share Summary:LinkedInEmail

For engineers evaluating materials for alkaline fuel cells, catalyst activity is only part of the equation: the active material must also be accessible to reactants. A porous graphene ORR catalyst addresses a practical limitation of conventional graphene supports, where sheet aggregation can conceal supported nanoparticles. In research presented in Malawi’s 2017 National Commission for Science and Technology conference proceedings, porous graphene (PGR) was used to support nickel cobaltite (NiCo2O4), with the aim of exposing more catalyst sites to oxygen during the oxygen reduction reaction (ORR).

The work is relevant to a broader engineering challenge: reducing reliance on platinum-based catalysts while retaining useful ORR activity. Its findings concern laboratory electrocatalyst performance in alkaline solution; they do not, by themselves, establish performance in a commercial fuel-cell system.

Why catalyst accessibility matters in the ORR

The ORR takes place at a fuel cell’s cathode and is central to converting chemical energy into electricity. Because the reaction kinetics can be slow, a catalyst is used to promote the reaction. Platinum-based materials are widely recognized for ORR activity, but their cost, scarcity, and durability concerns have driven interest in alternatives, including transition-metal oxides and carbon-supported materials.

Graphene is attractive as a catalyst support, but its sheets can stack through interactions between their surfaces. When that happens, nanoparticles may become trapped between layers or hidden within aggregates. Oxygen and other reactants then have less access to some of the supported material, limiting how much of the catalyst is available to participate in the reaction.

This distinction between catalyst loading and catalyst utilization is important. Adding more active material does not necessarily make all of it accessible. A support structure that prevents excessive stacking may help expose existing active sites rather than simply increasing the amount of catalyst.

How porous graphene supports NiCo2O4

The study used silica (SiO2) particles as a temporary template to create pores in graphene. Graphene oxide was combined with the silica particles, then thermally treated. After the silica was removed, pores remained in the resulting porous graphene. NiCo2O4 was subsequently deposited on the PGR support. A nonporous graphene-supported NiCo2O4 material was also prepared for comparison.

The pores change the geometry of the support. Instead of forming a tightly stacked, largely nonporous structure, PGR has openings that help keep its framework accessible. The researchers reported that NiCo2O4 particles remained present on the porous graphene and that the porous structure was retained after deposition.

Surface-area measurements also showed a difference between the supports. The reported BET specific surface areas were 309.4, 252.0, and 221.2 m2 g-1 for PGR made using different silica template sizes, compared with 182.8 m2 g-1 for nonporous graphene. The smallest-template PGR had the largest measured surface area among the tested supports. These measurements describe the prepared materials; they should not be interpreted as a direct measure of full-scale fuel-cell performance.

Porous graphene ORR catalyst performance

Electrochemical testing compared NiCo2O4/PGR with NiCo2O4 supported on nonporous graphene, PGR alone, and platinum on carbon (Pt/C). Tests were carried out in oxygen-saturated 0.1 M potassium hydroxide solution. The reported cyclic voltammetry results showed an oxygen-reduction peak for each catalyst, while NiCo2O4/PGR-110 had a more positive reduction peak than NiCo2O4/graphene. The authors associated the improvement with greater exposure of NiCo2O4 active sites on the porous support.

The reported trend also linked smaller PGR pore size with increased ORR activity. In the study’s interpretation, the PGR structure creates more accessible surface for supported NiCo2O4 and helps oxygen reach the catalyst. The combination brings together the porous support’s structure and the oxide’s catalytic contribution.

The study further reported good long-term stability and fuel-crossover resistance for NiCo2O4/PGR in alkaline medium, describing it as performing better on these measures than commercial Pt/C under the conditions examined. These are study-specific findings, not a general guarantee of performance across fuel-cell designs, operating conditions, or service life.

Engineering considerations for catalyst development

For technical teams assessing emerging catalyst materials, this work highlights several practical considerations:

  • Look beyond composition. The support architecture can affect how much of a catalyst is exposed to reactants.
  • Assess dispersion and access. Microscopy and surface-area characterization can help establish whether particles are distributed on an accessible support rather than concealed within stacked layers.
  • Match pore structure to the application. The reported relationship between template size, surface area, and ORR activity suggests that support design can influence electrochemical behavior.
  • Separate laboratory results from system validation. Electrode tests in alkaline electrolyte are useful for comparing materials, but further validation is needed before drawing conclusions about complete fuel-cell operation.

These considerations apply broadly to catalyst-support development: performance depends not only on the chemistry of an active material but also on how the support presents that material to the reaction environment.

Conclusion: structure influences catalyst utilization

The NiCo2O4/PGR research illustrates how a porous graphene support can address a limitation of stacked graphene sheets: reduced access to supported catalyst particles. In the reported alkaline ORR tests, NiCo2O4 on PGR showed improved activity compared with NiCo2O4 on nonporous graphene, alongside reported stability and crossover-resistance benefits under the tested conditions.

For industrial automation and energy-system decision-makers, the practical takeaway is to evaluate catalyst accessibility alongside material composition. Porous supports offer a design route for improving active-site exposure, but laboratory findings should be treated as a foundation for further application-specific testing—not as a substitute for system-level qualification.