Efficient AC-to-DC conversion matters wherever electronic equipment draws substantial power. In data centres and other demanding installations, energy lost as heat adds to operating costs and increases the burden on cooling systems. A SiC Totem Pole PFC offers a way to address one important source of conversion loss: the diode bridge commonly used at the input of a power supply.
The topology uses silicon carbide (SiC) MOSFETs in a bridgeless power factor correction (PFC) stage. A 3.6 kW demonstrator showed that this approach can deliver high efficiency at a 100 kHz switching frequency. Understanding its operating principle and the conditions behind those results can help engineers assess its suitability for power supply designs.
Why the AC-to-DC stage matters
Most modern electronic loads, including computer processors, require direct current (DC), while the grid supplies alternating current (AC). A power supply unit (PSU) therefore converts the incoming AC to DC and establishes a voltage suitable for the equipment. A separate DC-to-DC stage may then provide further conversion and, in many designs, galvanic isolation.
For a single-phase PSU, the input may range from 85 to 265 V at 50 or 60 Hz. The AC-to-DC stage also commonly provides PFC, shaping the input current to follow the supply voltage. Its efficiency contributes directly to the efficiency of the complete PSU.
This is especially relevant to high-efficiency certification targets. To meet the stated 80 Plus Titanium requirement for a redundant supply, the PSU must reach at least 96% efficiency at 50% of rated load with a 230 V input, while also meeting targets at other load levels and at 115 V. If the DC-to-DC stage achieves 98% efficiency, the AC-to-DC stage must also reach about 98% at half load for the complete unit to achieve 96% under that condition.
How SiC Totem Pole PFC reduces bridge losses
A conventional boost PFC stage uses a low-frequency diode rectifier bridge ahead of the boost converter. The bridge is straightforward to implement, but its conduction losses limit the maximum efficiency that the overall stage can achieve. Interleaving two boost phases is one way to support higher output power, but it does not remove the input bridge.
Bridgeless alternatives avoid that rectifier. A two-phase bridgeless PFC can perform well, but each bridge leg operates during only half of the grid cycle. This means the components are not used continuously across the full cycle. The Totem Pole PFC is another bridgeless option, and its practical use has become more attractive with wide-bandgap devices such as SiC MOSFETs.
The challenge for earlier implementations was the high-frequency switching leg. Silicon superjunction (SJ) MOSFET body diodes are not well suited to the hard commutation required in continuous-current mode (CCM). Operating in discontinuous-current mode (DCM) can avoid that issue, but results in higher ripple current. SiC MOSFET body diodes have low reverse-recovery losses, making hard commutation more suitable and enabling CCM operation with lower ripple current.
Understanding the Totem Pole switching sequence
The circuit uses two high-frequency switches, Q1 and Q2, and two switches, Q3 and Q4, that operate at the grid frequency. SiC MOSFETs are used for Q1 and Q2 because of the demands on their switching leg. The line-frequency switches do not require the same high-performance body-diode characteristics; the described design uses Si SJ MOSFETs, although diodes are also an option for a lower-cost design with somewhat lower performance.
During the positive half-cycle of the AC input, Q4 remains on. When the primary boost switch Q2 turns on, current rises through the input inductor. When Q2 turns off, current transfers to the body diode of Q1 after a short dead time. Q1 is then turned on so that its channel carries the current, a process called synchronous rectification.
During the negative half-cycle, Q1 and Q2 exchange their roles as primary switch and synchronous rectifier. Current flows through Q3, while Q4 remains off. In both half-cycles, the SiC MOSFET body diodes are hard-commutated, but their low reverse-recovery losses support this mode of operation.
What the 3.6 kW demonstrator showed
The demonstrator was designed for an 85–265 V, 50 Hz input, a 400 V output, and a maximum output power of 3,600 W at 230 V input. Its switching frequency was 100 kHz. The high-frequency leg used 650 V, 60 mΩ SiC trench MOSFETs; 600 V, 60 mΩ Si SJ MOSFETs served in the grid-frequency leg.
Measurements were taken across the output power range at both 110 V and 230 V input. At 230 V, peak efficiency reached 98.5%, and efficiency remained above 98% from approximately 500 W through full load. These results demonstrate the performance of this particular setup; they are not a guarantee of the same efficiency in every PSU design.
Thermal measurements also showed case temperatures of approximately 100°C at full output power, with an ambient temperature of 25°C. The design discussion identifies loss reduction and improvements to the cooling path as ways to support thermal stability at higher ambient temperatures. Component selection, gate driving, switching conditions and thermal design therefore remain important parts of applying the topology.
Practical implications for power supply design
For engineers evaluating an AC-to-DC stage, the central advantage of Totem Pole PFC is that it avoids the conduction losses of a conventional input diode bridge. SiC MOSFETs make CCM operation practical by addressing the reverse-recovery challenge that restricted earlier silicon-based implementations. The demonstrator’s results indicate that the topology can support efficiency levels relevant to demanding PSU targets, including those associated with 80 Plus Titanium, when the DC-to-DC stage also achieves the required efficiency.
System-level evaluation is essential: certification depends on performance at specified input voltages and load points, not only on peak efficiency. Designers must also account for semiconductor losses and temperatures under their intended operating conditions. For industrial power supplies and data-centre equipment, SiC-based Totem Pole PFC is a useful option to consider when reducing AC-to-DC losses is a design priority.