As power conversion systems become more compact, managing heat in power semiconductor devices becomes a more demanding part of thermal design. A transient thermal network model helps engineers estimate how junction temperature changes over time, including during overload or fault-current conditions. Identifying that model from measurements, however, can be difficult when noise in the measured signal affects the calculations used to extract thermal parameters.
A noise-aware signal-processing method addresses this challenge by working with measurements in logarithmic time and applying frequency-domain filtering before deconvolution. The approach is relevant to power module thermal characterization because it aims to make the resulting thermal structure easier to interpret without changing the underlying measurement method.
Why transient thermal behavior matters
Heat generated at a semiconductor junction travels through the package layers toward the heat sink. The path depends on the package’s structure and material properties. A steady-state thermal resistance describes the temperature difference between the junction and case once conditions have stabilized, but it does not describe how temperature evolves during a changing load.
For that time-dependent analysis, engineers use a thermal network made from resistance and capacitance elements. The network can represent the response of junction temperature to power dissipation and support thermal assessment under operating conditions that do not remain steady.
Two common representations serve different purposes:
- Cauer networks use a cascade of thermal resistance and capacitance pairs. Their structure can correspond to layers and heat-flow regions in the physical package.
- Foster networks represent thermal behavior as a sum of exponential responses. Their parameters are useful for modeling, but do not directly map to package layers.
Measurements are typically used to identify a Foster representation first. A numerical Foster-Cauer transformation can then produce a Cauer network, while a structure function can help show cumulative thermal capacitance in relation to cumulative thermal resistance.
Using the static test method
The static test method obtains the temperature response during cooling after a device has been heated to thermal equilibrium. The device under test is mounted on a temperature-controlled coldplate, and a heating current is applied until the device reaches equilibrium. After the heating current is switched off, a small measurement current is used to track junction voltage during cooling.
Because the device’s current-voltage characteristics vary with temperature, the measured junction voltage can be converted to junction temperature using a temperature-sensitive electrical parameter, or TSEP. The relationship between voltage and temperature for the specified current is established through a calibration known as the K factor. The temperature response is then normalized by the applied heating power to obtain a response suitable for thermal network identification.
The cooling response contains information about the device’s thermal time constants. Extracting that information involves a deconvolution calculation. In the conventional processing sequence, noise is reduced with a moving-average filter before the data is converted to logarithmic time. Residual noise can become more prominent during numerical differentiation, making the resulting thermal time constant spectrum harder to interpret.
Improving identification in logarithmic time
Heat-transfer responses often span a wide range of time constants, so the identification process uses a logarithmic time axis. Measurements initially sampled at uniform intervals in linear time become nonuniformly spaced after this conversion. Processing every converted sample can also create unnecessary computational work. Decimation reduces the data volume while retaining a time resolution selected for the time constants of interest.
The noise-aware method changes how the converted signal is processed. It differentiates the response in logarithmic time and applies a weighted discrete Fourier transform (DFT) suited to the nonuniform sample spacing. A low-pass filter in the frequency domain then reduces unwanted high-frequency content. The filtered signal is returned to logarithmic time using an inverse discrete Fourier transform, after which Bayesian deconvolution estimates the thermal time constant spectrum.
That spectrum is used to determine the Foster thermal network. The Foster-Cauer transformation then provides a Cauer representation, from which engineers can examine the package’s thermal structure. Filtering requires a balance: suppressing noise while retaining enough detail to resolve meaningful features in the response. The filter bandwidth and edge steepness therefore need to be selected with resolution and noise reduction in mind.
Measurement quality and practical interpretation
Signal processing cannot be separated from measurement quality. The analysis of quantization effects shows that ADC bit depth and sampling frequency influence the noise floor. Oversampling can reduce the effect of quantization error after filtering and decimation, but the effective bit depth for the actual input signal matters; a converter’s nominal resolution alone does not describe the measurement’s usable resolution.
In evaluations using simulated responses, the frequency-domain filtering reduced the influence of added white noise compared with the conventional moving-average approach. The difference was visible in the thermal time constant spectrum: the conventional result could include unintended peaks at short time constants, while the noise-aware result more clearly represented intended features. Measurements on a discrete SiC diode and a power module with a DBC substrate also showed clearer structure-function features with the developed processing method.
These results do not remove the need for careful testing. Junction-temperature estimation depends on the K-factor calibration, and the identified network depends on the measured cooling response and the choices made in data processing. Engineers should interpret structure-function features alongside knowledge of the device and package, rather than treating every feature as an unambiguous physical boundary.
Practical implications for thermal design
For engineers and system integrators, the key benefit of improved transient thermal network identification is a more usable representation of how heat moves through a power package over time. A Cauer model and its structure function can help distinguish thermal contributions from package layers, including structures that may be difficult to separate when their thermal resistance is low.
When planning characterization, give attention to the complete measurement chain: establish the TSEP calibration, capture the cooling response with suitable sampling, consider ADC resolution and effective input range, and select logarithmic-time decimation and frequency filtering to match the required time resolution. The practical objective is not simply to produce a network, but to obtain one whose features can be interpreted with confidence and applied appropriately in transient thermal analysis.